imaging technique
Recently Published Documents


TOTAL DOCUMENTS

3263
(FIVE YEARS 645)

H-INDEX

71
(FIVE YEARS 8)

2022 ◽  
Vol 8 ◽  
Author(s):  
Takashi Kubo ◽  
Kosei Terada ◽  
Yasushi Ino ◽  
Yasutsugu Shiono ◽  
Shengxian Tu ◽  
...  

Recent advances in intravascular imaging techniques have made it possible to assess the culprit lesions of acute coronary syndrome (ACS) in the clinical setting. Intravascular ultrasound (IVUS) is the most commonly used intravascular imaging technique that provides cross-sectional images of coronary arteries. IVUS can assess plaque burden and vessel remodeling. Optical coherence tomography (OCT) is a high-resolution (10 μm) intravascular imaging technique that uses near-infrared light. OCT can identify key features of atheroma, such as lipid core and thin fibrous cap. Near-infrared spectroscopy (NIRS) can detect lipid composition by analyzing the near-infrared absorption properties of coronary plaques. NIRS provides a chemogram of the coronary artery wall, which allows for specific quantification of lipid accumulation. These intravascular imaging techniques can depict histological features of plaque rupture, plaque erosion, and calcified nodule in ACS culprit lesions. However, no single imaging technique is perfect and each has its respective strengths and limitations. In this review, we summarize the implications of combined use of multiple intravascular imaging techniques to assess the pathology of ACS and guide lesion-specific treatment.


2022 ◽  
Vol 12 (2) ◽  
pp. 816
Author(s):  
Jordan Colman ◽  
Laura Mancini ◽  
Spyros Manolopoulos ◽  
Meetakshi Gupta ◽  
Michael Kosmin ◽  
...  

Despite the increasing precision of radiotherapy delivery, it is still frequently associated with neurological complications. This is in part due to damage to eloquent white matter (WM) tracts, which is made more likely by the fact they cannot be visualised on standard structural imaging. WM is additionally more vulnerable than grey matter to radiation damage. Primary brain malignancies also are known to spread along the WM. Diffusion tensor imaging (DTI) is the only in vivo method of delineating WM tracts. DTI is an imaging technique that models the direction of diffusion and therefore can infer the orientation of WM fibres. This review article evaluates the current evidence for using DTI to guide intracranial radiotherapy and whether it constitutes a new state-of-the-art technique. We provide a basic overview of DTI and its known applications in radiotherapy, which include using tractography to reduce the radiation dose to eloquent WM tracts and using DTI to detect or predict tumoural spread. We evaluate the evidence for DTI-guided radiotherapy in gliomas, metastatic disease, and benign conditions, finding that the strongest evidence is for its use in arteriovenous malformations. However, the evidence is weak in other conditions due to a lack of case-controlled trials.


2022 ◽  
Vol 2022 ◽  
pp. 1-10
Author(s):  
Yalda Mirzaei ◽  
Kerstin Hagemeister ◽  
Martina Hüffel ◽  
Timo Schwandt ◽  
René H. Tolba ◽  
...  

Background. Tissue glues can minimize treatment invasiveness, mitigate the risk of infection, and reduce surgery time; ergo, they have been developed and used in surgical procedures as wound closure devices beside sutures, staples, and metallic grafts. Regardless of their structure or function, tissue glues should show an acceptable microbial barrier function before being used in humans. This study proposes a novel in vitro method using Escherichia coli Lux and bioluminescence imaging technique to assess the microbial barrier function of tissue glues. Different volumes and concentrations of E. coli Lux were applied to precured or cured polyurethane-based tissue glue placed on agar plates. Plates were cultured for 1 h, 24 h, 48 h, and 72 h with bioluminescence signal measurement subsequently. Herein, protocol established a volume of 5 μL of a 1 : 100 dilution of E. coli Lux containing around 2 × 10 7  CFU/mL as optimal for testing polyurethane-based tissue glue. Measurement of OD600nm, determination of CFU/mL, and correlation with the bioluminescence measurement in p/s unit resulted in a good correlation between CFU/mL and p/s and demonstrated good reproducibility of our method. In addition, this in vitro method could show that the tested polyurethane-based tissue glue can provide a reasonable barrier against the microbial penetration and act as a bacterial barrier for up to 48 h with no penetration and up to 72 h with a low level of penetration through the material. Overall, we have established a novel, sensitive, and reproducible in vitro method using the bioluminescence imaging technique for testing the microbial barrier function of new tissue glues.


2022 ◽  
Vol 43 (3) ◽  
Author(s):  
Gavin Sutton ◽  
Sofia Korniliou ◽  
Aurik Andreu ◽  
David Wilson

AbstractAccurate temperature measurements are critical in manufacturing, affecting both product quality and energy consumption. At elevated temperatures, non-contact thermometers are often the only option. However, such instruments require prior knowledge of the surface emissivity, which is often unknown or difficult to determine, leading to large errors. Here we present a novel imaging luminescence thermometer based on the intensity ratio technique using magnesium fluorogermanate phosphor, with the potential to overcome this limitation. We describe measurements performed on a number of engineering alloys undergoing heat treatment at temperatures of up to 750 °C and compare these measurements against a traditional contact thermocouple and thermal imager system. Agreement between the luminescence and embedded thermocouple temperatures was found to be better than 45 °C at all temperatures. However, the thermal imager measurement on the bare metal samples, with the instrument emissivity set to 1.0, showed differences of up to 500 °C at 750 °C, a factor of 10 larger. In an effort to improve the thermal imager accuracy, its instrument emissivity was adjusted until its temperature agreed with that of the thermocouple. When measuring on the bare metal, the effective emissivity was strongly sample dependent, with mean values ranging from 0.205 to 0.784. Since the phosphor derived temperatures exhibited substantially smaller errors compared to the thermal imager, it is suggested that this method can be used to compliment the thermal imaging technique, by providing a robust mechanism for adjustment of the instrument emissivity until agreement between the thermal imager and phosphor thermometer is obtained.


Author(s):  
Marieke Zimmerman ◽  
Michael Schramme ◽  
Anthony Barthélemy ◽  
Tom Mariën ◽  
Aurélie Thomas‐Cancian ◽  
...  
Keyword(s):  

2022 ◽  
Vol 128 ◽  
pp. 114432
Author(s):  
Shijun Zheng ◽  
Ran Chen ◽  
Jianli Yang ◽  
Yanfen Wang ◽  
Yi Che ◽  
...  

2022 ◽  
Vol 2149 (1) ◽  
pp. 012014
Author(s):  
J Christinck ◽  
B Rodiek ◽  
M López ◽  
H Georgieva ◽  
H Hofer ◽  
...  

Abstract We report on the characterization of the angular-dependent emission of two different single-photon emitters based on nitrogen-vacancy centers in nanodiamond and on core-shell CdSe/CdS quantum dot nanoparticles. The emitters were characterized in a confocal microscope setup by spectroscopy and Hanbury-Brown and Twiss interferometry. The angular-dependent emission is measured using a back focal plane imaging technique. A theoretical model of the angular emission patterns of the 2D dipoles of the emitters is developed to determine their orientation. Experiment and model agree well with each other.


Molecules ◽  
2021 ◽  
Vol 27 (1) ◽  
pp. 258
Author(s):  
Elzbieta Pach ◽  
Albert Verdaguer

Scanning electron microscopy (SEM) is a powerful imaging technique able to obtain astonishing images of the micro- and the nano-world. Unfortunately, the technique has been limited to vacuum conditions for many years. In the last decades, the ability to introduce water vapor into the SEM chamber and still collect the electrons by the detector, combined with the temperature control of the sample, has enabled the study of ice at nanoscale. Astounding images of hexagonal ice crystals suddenly became real. Since these first images were produced, several studies have been focusing their interest on using SEM to study ice nucleation, morphology, thaw, etc. In this paper, we want to review the different investigations devoted to this goal that have been conducted in recent years in the literature and the kind of information, beyond images, that was obtained. We focus our attention on studies trying to clarify the mechanisms of ice nucleation and those devoted to the study of ice dynamics. We also discuss these findings to elucidate the present and future of SEM applied to this field.


Sign in / Sign up

Export Citation Format

Share Document