scholarly journals A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector

Author(s):  
M.W. Aslin ◽  
A. Hannaman ◽  
M.D. Youngs ◽  
A.B. McIntosh ◽  
A. Abbott ◽  
...  
2018 ◽  
Vol 13 (12) ◽  
pp. C12015-C12015
Author(s):  
G. Thungström ◽  
A. Lundgren ◽  
R. H. Menk ◽  
L. Westerberg ◽  
C. Fröjdh

2015 ◽  
Vol 738-739 ◽  
pp. 93-96
Author(s):  
Wei Chen ◽  
Si Hai Chen ◽  
Dong Luo

Due to its high position resolution and fast speed, the position sensitive detector (PSD) is widely applied in micro displacement measurement. However, almost all PSDs suffer from high nonlinearity. In this paper, three kinds of PSDs and their advantages and disadvantages are introduced. Then principle of pin-cushion PSD is studied, based on which a new signal processing system is designed. The signal processing system consists of a high-precision sensor circuit and a software system integrated with a correction algorithm. The test result shows the linearity of the PSD is greatly improved.


Author(s):  
Jiaxing Li

A CsI(T1) scintillation detector with a two-dimension position-sensitive photomultiplier readout at RIBLL is developed. The position resolution of the detector was obtained with RIB 17N, and the performance of detector was simulated by using GEANT4. The simulation results accorded with the experimental ones. The reflection factor of the aluminum foil outside the scintillator plays an important role on the position resolution.


2008 ◽  
Vol 8 (10) ◽  
pp. 1704-1709 ◽  
Author(s):  
Henrik A. Andersson ◽  
Kent Bertilsson ◽  
GÖran Thungstrom ◽  
Hans-Erik Nilsson

Metrologiya ◽  
2020 ◽  
pp. 38-51
Author(s):  
V. N. Astapov ◽  
I. N. Kozlova

This article presents the rationale and methodology for developing an intrinsically safe device, namely, a hydrostatic fiber optic sensor with a position-sensitive detector for monitoring the level of oil products in large-capacity tanks at oil depots and during pumping in a raw material warehouses. This device suitable for continuous monitoring of the liquid level, based on the measurement of a hydrostatic column of liquid with automatic offset of changes in the density of the liquid. Offset is carried out by means of a displacer (a fully submerged float), inside which a housing with a position-sensitive detector (PSD) is integrated. Theoretical validation of the bellows suspension usage for a displacer is given. During filling a container with a liquid whose level is measured, liquid bellows, the movement of which is recorded by an optical triangulation sensor using the reflected infrared ray incident on the bottom of the bellows. The principle of the triangulation sensor operation is based on the geometric properties of the triangles. The pulses of infrared radiation come through a fiber optic cable. In order to measure the movement of the surface (the bottom of the bellows) by measuring the movement of the reflected beam, a position-sensitive detector is used, which is located in a remote controller. In this device for the intrinsic safety problem solution, optical inputs of a fiber optic flat cable are located in the active zone of the sensor, which is connected to the optical inputs of a position-sensitive detector, operated on the principles of photoelectric effect. The light spot moving along the sensitive zone and converted by the detector into a one-dimensional signal proportional to the distance to the object. hydrostatically applies pressure over the entire effective area of the measuring


2020 ◽  
Vol 86 (6) ◽  
pp. 29-35
Author(s):  
V. P. Sirotinkin ◽  
O. V. Baranov ◽  
A. Yu. Fedotov ◽  
S. M. Barinov

The results of studying the phase composition of advanced calcium phosphates Ca10(PO4)6(OH)2, β-Ca3(PO4)2, α-Ca3(PO4)2, CaHPO4 · 2H2O, Ca8(HPO4)2(PO4)4 · 5H2O using an x-ray diffractometer with a curved position-sensitive detector are presented. Optimal experimental conditions (angular positions of the x-ray tube and detector, size of the slits, exposure time) were determined with allowance for possible formation of the impurity phases during synthesis. The construction features of diffractometers with a position-sensitive detector affecting the profile characteristics of x-ray diffraction peaks are considered. The composition for calibration of the diffractometer (a mixture of sodium acetate and yttrium oxide) was determined. Theoretical x-ray diffraction patterns for corresponding calcium phosphates are constructed on the basis of the literature data. These x-ray diffraction patterns were used to determine the phase composition of the advanced calcium phosphates. The features of advanced calcium phosphates, which should be taken into account during the phase analysis, are indicated. The powder of high-temperature form of tricalcium phosphate strongly adsorbs water from the environment. A strong texture is observed on the x-ray diffraction spectra of dicalcium phosphate dihydrate. A rather specific x-ray diffraction pattern of octacalcium phosphate pentahydrate revealed the only one strong peak at small angles. In all cases, significant deviations are observed for the recorded angular positions and relative intensity of the diffraction peaks. The results of the study of experimentally obtained mixtures of calcium phosphate are presented. It is shown that the graphic comparison of experimental x-ray diffraction spectra and pre-recorded spectra of the reference calcium phosphates and possible impurity phases is the most effective method. In this case, there is no need for calibration. When using this method, the total time for analysis of one sample is no more than 10 min.


Sign in / Sign up

Export Citation Format

Share Document