29.33Pathological Tc-99m sestamibi myocardial perfusion scintigraphy is independently associated with referral to early catheterization and pathological angiographic results as well as emerging cardiac events in patients aged 70 years and older

2006 ◽  
Vol 13 (4) ◽  
pp. S35-S36
Author(s):  
J BUCERIUS ◽  
A JOE ◽  
E HERDER ◽  
H PALMEDO ◽  
S EZZIDDIN ◽  
...  
2008 ◽  
Vol 15 (4) ◽  
pp. S37-S37
Author(s):  
J SLHESSARENKO ◽  
H PORTELA ◽  
F RUA ◽  
M XIMENA ◽  
F ALVES ◽  
...  

2021 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
P Haaf ◽  
F Caobelli ◽  
G Haenny ◽  
M Pfisterer ◽  
MJ Zellweger

Abstract Funding Acknowledgements Type of funding sources: Public grant(s) – National budget only. Main funding source(s): Swiss National Foundation for Research Background Asymptomatic diabetic patients with an abnormal myocardial perfusion scintigraphy (MPS) are known to be at an increased risk of major cardiac events (MACE) at 2-years follow-up. It remains unclear whether this finding holds true even for a follow-up of 5 years. Methods four hundred patients with type-2 diabetes without coronary artery disease were evaluated clinically and with MPS and followed up for 5 years. Major adverse cardiovascular events (MACE) were defined as cardiac death, myocardial infarction or late coronary revascularization.  Results  An abnormal MPS (SSS≥4 or SSS≥2) was found in 87 patients (21.8%). MACE within 5 years occurred in 14 patients with abnormal MPS (16.1%) and in 22 with normal scan (1.7%, p = 0.009); 15 deaths were recorded (3.8%). Patients with normal MPS had lower rates of MACEs than patients with abnormal scans (p = 0.016) (Figure 1A + B). Patients with abnormal MPS who had undergone revascularization had a lower mortality rate and a better event free survival from MI and revascularization than patients with abnormal MPS who had either undergone medical therapy only or could not be revascularized (Figure 1C + D).  Conclusions Patients with  normal MPS have a low event rate and may not need retesting within 5 years (warranty period). Patients with an abnormal MPS have higher event rates and may benefit from a combined medical and revascularization approach. Abstract Figure 1 A-D


2015 ◽  
Vol 66 (2) ◽  
pp. 125-129 ◽  
Author(s):  
Francesco Nudi ◽  
Giandomenico Neri ◽  
Orazio Schillaci ◽  
Annamaria Pinto ◽  
Enrica Procaccini ◽  
...  

2007 ◽  
Vol 46 (02) ◽  
pp. 49-55 ◽  
Author(s):  
W. Burchert ◽  
F. M. Bengel ◽  
R. Zimmermann ◽  
J. vom Dahl ◽  
W. Schäfer ◽  
...  

SummaryThe working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine (DGN), in cooperation with the working group Nuclear Cardiology of the German Cardiac Society (DGK), decided to conduct a national survey on myocardial perfusion scintigraphy (MPS). Method: A questionnaire to evaluate MPS for the year 2005 was sent. Results: 346 completed questionnaires had been returned (213 private practices, 99 hospitals and 33 university hospitals). MPS of 112 707 patients were reported with 110 747 stress and 95 878 rest studies. The majority (>75%) was performed with 99mTc-MIBI or tetrofosmin. 201Tl stress-redistribution was used in 22 637 patients (20%). The types of stress were exercise in 78%, vasodilation with adenosine or dipyridamol in 21% and dobutamine in 1%. 99.97% of all MPS were SPECT studies. Gated SPECT was performed in 36% of the stress and in 32% of the rest studies. An attenuation correction was used in 21%. 29 institutions (8%) performed gated SPECT (stress and rest) and attenuation correction. 47% of all MPS were requested by ambulatory care cardiologists, 17% by internists, 12% by primary care physicians, 21% by hospital departments and 2% by others. Conclusion: In Germany, MPS is predominantly performed with 99mTc-perfusion agents. The common type of stress is ergometry. Gated SPECT and attenuation correction do not yet represent standards of MPS practice in Germany, which indicates some potential of optimization.


1998 ◽  
Vol 37 (08) ◽  
pp. 268-271
Author(s):  
B. Caner ◽  
E. Atalar ◽  
A. Karanfil ◽  
L. Tokgözoğlu ◽  
E. L. Ergün

Summary Aim: Dobutamine as a predominant beta-1 agonist increases heart rate and myocardial contractility and at sufficient high doses, it also increases systolic blood pressure. This study was undertaken to describe instances of paradoxical hypotension during dobutamine infusion for TI-201 myocardial perfusion SPECT study and the relationship between scintigraphic findings and hypotension occurred during dobutamine infusion. Methods: In 201 consecutive patients unable to perform adequate exercise, dobutamine TI-201 myocardial SPECT was performed. Dobutamine was infused starting from 10 μg/kg/min increasing to 40 μg/kg/min. Paradoxical hypotension was defined as a decrease in systolic blood pressure ≥ 20 mmHg compared with baseline study. Results: Paradoxical hypotension was observed in 40 patients (Group A) out of 201 (19.9%) while no significant change in systolic blood pressure was detected in the remaining 161 patients (Group B). Mean maximum fall in systolic blood pressure was 39 ± 18 mmHg (range: 20-90). In 33 of 40 patients (83%) with paradoxical hypotension, scintigraphy was normal compared to 131 (81%) of the remaining 161 patients. In patients of Group A, angiography, echocardiography and tilt table tests were performed in 13, 11 and 6 patients respectively. Nine of 13 angiographic evaluations (69%), 10 of 11 echocardiographic evaluations (91%), all of the tilt table tests were normal. Additionally, all of the patients of Group A were clinically followed up at least 6 months after the myocardial perfusion scintigraphy. None of the patients had a cardiac event except one patient during the follow-up period. Conclusion: Paradoxical hypotension during dobutamine infusion for myocardial scintigraphy is not an uncommon finding and up to 19.9% patients may develop such hypotension. To maximize test safety, precautions should be taken during dobutamine myocardial stress test, since remarkable decrease in systolic blood pressure may occur. Unlike hypotension occurring with exercise test, hypotension response to dobutamine is not always a marker for coronary artery disease.


Sign in / Sign up

Export Citation Format

Share Document