scholarly journals Evaluation of the SENTIFIT-FOB gold faecal immunochemical test for the presence of haemoglobin using the automated Roche Cobas 8000 system

2022 ◽  
pp. e00263
Author(s):  
Lutz Schwettmann ◽  
Astrid Lied ◽  
Ragnar Eriksen
Gut ◽  
2016 ◽  
Vol 66 (8) ◽  
pp. 1441-1448 ◽  
Author(s):  
Sunny H Wong ◽  
Thomas N Y Kwong ◽  
Tai-Cheong Chow ◽  
Arthur K C Luk ◽  
Rudin Z W Dai ◽  
...  

Gut ◽  
2021 ◽  
pp. gutjnl-2020-322545
Author(s):  
Han-Mo Chiu ◽  
Grace Hsiao-Hsuan Jen ◽  
Ying-Wei Wang ◽  
Jean Ching-Yuan Fann ◽  
Chen-Yang Hsu ◽  
...  

ObjectiveTo measure the effects of faecal immunochemical test (FIT) for colorectal cancer (CRC) screening on overall and site-specific long-term effectiveness of population-based organised service screening.DesignA prospective cohort study of Taiwanese nationwide biennial FIT screening was performed. A total of 5 417 699 eligible subjects were invited to attend screening from 2004 through 2009 and were followed up until 2014. We estimated the adjusted relative rates (aRRs) on the effectiveness of reducing advanced-stage CRC (stage II+) and CRC death by Bayesian Poisson regression models with the full adjustment for a cascade of self-selection factors (including the screening rate and the colonoscopy rate) and the completeness of colonoscopy together with demographic features.ResultsFIT screening (exposed vs unexposed) reduced the incidence of advanced-stage CRC (48.4 vs 75.7 per 100 000) and mortality (20.3 vs 41.3 per 100 000). Statistically significant reductions of both incidence of advanced-stage CRCs (aRR=0.66, 95% CI 0.63 to 0.70) and deaths from CRC (aRR=0.60, 95% CI 0.57 to 0.64) were noted. FIT screening was more effective in reducing distal advanced-stage CRCs (aRR=0.61, 95% CI 0.58 to 0.64) and CRC mortality (aRR=0.56, 95% CI 0.53 to 0.69) than proximal advanced CRCs (aRR=0.84, 95% CI 0.77 to 0.92) and CRC mortality (aRR=0.72, 95% CI 0.66 to 0.80).ConclusionA large-scale population-based biennial FIT screening demonstrates 34% significant reduction of advanced-stage CRCs and 40% reduction of death from CRC with larger long-term effectiveness in the distal colon than the proximal colon. Our findings provide a strong and consistent evidence-based policy for supporting a sustainable population-based FIT organised service screening worldwide. The disparity of site-specific long-term effectiveness also provides an insight into the remedy for lower effectiveness of FIT screening in the proximal colon.


Author(s):  
Caroline J. Chapman ◽  
Ayan Banerjea ◽  
David J Humes ◽  
Jaren Allen ◽  
Simon Oliver ◽  
...  

AbstractObjectivesCurrently, NICE recommends the use of faecal immunochemical test (FIT) at faecal haemoglobin concentrations (f-Hb) of 10 μg Hb/g faeces to stratify for colorectal cancer (CRC) risk in symptomatic populations. This f-Hb cut-off is advised across all analysers, despite the fact that a direct comparison of analyser performance, in a clinical setting, has not been performed.MethodsTwo specimen collection devices (OC-Sensor, OC-S; HM-JACKarc, HM-J) were sent to 914 consecutive individuals referred for follow up due to their increased risk of CRC. Agreement of f-Hb around cut-offs of 4, 10 and 150 µg Hb/g faeces and CRC detection rates were assessed. Two OC-S devices were sent to a further 114 individuals, for within test comparisons.ResultsA total of 732 (80.1%) individuals correctly completed and returned two different FIT devices, with 38 (5.2%) CRCs detected. Median f-Hb for individuals diagnosed with and without CRC were 258.5 and 1.8 µg Hb/g faeces for OC-S and 318.1 and 1.0 µg Hb/g faeces for HM-J respectively. Correlation of f-Hb results between OC-S/HM-J over the full range was rho=0.74, p<0.001. Using a f-Hb of 4 µg Hb/g faeces for both tests found an agreement of 88.1%, at 10 µg Hb/g faeces 91.7% and at 150 µg Hb/g faeces 96.3%. A total of 114 individuals completed and returned two OC-S devices; correlation across the full range was rho=0.98, p<0.001.ConclusionsWe found large variations in f-Hb when different FIT devices were used, but a smaller variation when the same FIT device was used. Our data suggest that analyser-specific f-Hb cut-offs are applied with regard to clinical decision making, especially at lower f-Hb.


2019 ◽  
Vol 145 (1) ◽  
pp. 110-121 ◽  
Author(s):  
Massimo Vicentini ◽  
Manuel Zorzi ◽  
Emanuela Bovo ◽  
Pamela Mancuso ◽  
Marco Zappa ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document