scholarly journals Analysis on the Performance of Ground Heat Exchangers in Ground Source Heat Pump Systems based on Heat Transfer Enhancements

2015 ◽  
Vol 121 ◽  
pp. 19-26 ◽  
Author(s):  
Yong Liu ◽  
Yuqiao Zhang ◽  
Shengqiang Gong ◽  
Zhenfei Wang ◽  
Huiting Zhang
2013 ◽  
Vol 700 ◽  
pp. 231-234
Author(s):  
Lian Yang ◽  
Yong Hong Huang ◽  
Liu Zhang

There are many ground source heat pumps in engineering construction application. However, Research on heat exchanger models of single-hole buried vertical ground source heat pump mostly focuses on single U-tube ground heat exchangers other than double U-tube ones in China currently. Compared with single U-tubes, double U-tubes have the heat transfer particularity of asymmetry. Therefore, the use of the traditional single tube models would have large error in the simulation of the actual double U-tube heat exchangers. This paper frames a three-dimensional heat transfer model for the vertical single-hole buried double u-tube heat exchanger in a ground source heat pump system. The model considers the performance of U-bube material and uses a dual coordinate system and makes the control elemental volumes superimposed.


2014 ◽  
Vol 548-549 ◽  
pp. 595-600
Author(s):  
Can Can Zhang ◽  
Yue Jin Yu

In order to analyze the influence of groundwater flow on ground heat exchangers with different arrangements, with a project in Nanjing the access temperature field in the multi-borehole field was simulated after the ground source heat pump system had been performed for a year. Simulation results show that the access temperature is higher in the ground surrounding the borehole than the center of the corresponding borehole, thus forming a thermal barrier surrounding the borehole. Groundwater flow helps relieve temperature imbalance owing to the imbalance of heating and cooling load. The performance of the ground heat exchangers is better in staggered arrangement than in aligned arrangement. In the borehole field, the boreholes upstream have thermal interference on those downstream. And the extent of thermal interference depends on the direction of the groundwater flow when the locations of the boreholes are fixed in the borehole field.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3919
Author(s):  
Yu Zhou ◽  
Asal Bidarmaghz ◽  
Nikolas Makasis ◽  
Guillermo Narsilio

Ground-source heat pump systems are renewable and highly efficient HVAC systems that utilise the ground to exchange heat via ground heat exchangers (GHEs). This study developed a detailed 3D finite element model for horizontal GHEs by using COMSOL Multiphysics and validated it against a fully instrumented system under the loading conditions of rural industries in NSW, Australia. First, the yearly performance evaluation of the horizontal straight GHEs showed an adequate initial design under the unique loads. This study then evaluated the effects of variable trench separations, GHE configurations, and effective thermal conductivity. Different trench separations that varied between 1.2 and 3.5 m were selected and analysed while considering three different horizontal loop configurations, i.e., the horizontal straight, slinky, and dense slinky loop configurations. These configurations had the same length of pipe in one trench, and the first two had the same trench length as well. The results revealed that when the trench separation became smaller, there was a minor increasing trend (0.5 °C) in the carrier fluid temperature. As for the configuration, the dense slinky loop showed an average that was 1.5 °C lower than those of the horizontal straight and slinky loop (which were about the same). This indicates that, when land is limited, compromises on the trench separation should be made first in lieu of changes in the loop configuration. Lastly, the results showed that although the effective thermal conductivity had an impact on the carrier fluid temperature, this impact was much lower compared to that for the GHE configurations and trench separations.


Sign in / Sign up

Export Citation Format

Share Document