Effect of distance between the abutment and the adjacent teeth on intraoral scanning: An in vitro study

Author(s):  
Mei-Yang Huang ◽  
KeunBaDa Son ◽  
Kyu-Bok Lee
2016 ◽  
Vol 27 (1) ◽  
pp. 88-93 ◽  
Author(s):  
Mahmoud Serag ◽  
Talal al Nassar ◽  
Dane Avondoglio ◽  
Saul Weiner

2021 ◽  
Vol 11 (21) ◽  
pp. 9859
Author(s):  
Hani Tohme ◽  
Ghida Lawand ◽  
Rita Eid ◽  
Khaled E. Ahmed ◽  
Ziad Salameh ◽  
...  

(1) Background: Stereophotogrammetry has recently been investigated showing high accuracy in complete implant supported cases but has scarcely been investigated in cases of tilted implants. The aim of this in vitro study was to compare the accuracy of digital impression techniques (intraoral scanning and photogrammetry) at the level of intraoral scan bodies in terms of angular deviations and 3D discrepancies. (2) Methods: A stone master cast representing an edentulous maxilla using four implant analogs was fabricated. The two anterior implants were parallel to each other, and the two posterior implants were at an angulation of 17 degrees. Digital intraoral scanning (DIOS) impressions were taken after connecting implant level scan bodies to the master cast and STL files were exported (n = 15). Digital photogrammetry (DPG) impressions were captured using a PiC Camera after tightening implant level PiC optical markers and STL files were exported (n = 15). Superimposition was carried out by a software for determining the accuracy of both. (3) Results: Significant angular discrepancies (ΔA) and 3D deviations of scan bodies were found among the groups in trueness with lower deviations for the DPG (p value < 0.001). However, trueness within ISBs varied between angular and 3D deviations and outcomes were not specific to determine the effect of implant angulation. In precision, no significant differences were detected within ISBs and among both groups in terms of angular deviation. However, DPG had less deviations than DIOS group in terms of 3D deviations (p value < 0.001). (4) Conclusion: Digital photogrammetry technique conveyed the utmost accuracy in both trueness and precision for the intraoral scan bodies among both impression methods assessed. In addition, implant angulation did not influence the precision of the impression techniques but affected their trueness without explicit conclusions.


Planta Medica ◽  
2016 ◽  
Vol 81 (S 01) ◽  
pp. S1-S381
Author(s):  
EM Pferschy-Wenzig ◽  
K Koskinen ◽  
C Moissl-Eichinger ◽  
R Bauer

2003 ◽  
Vol 48 (1) ◽  
pp. 7 ◽  
Author(s):  
Dong Hyun Kim ◽  
Sung Gwon Kang ◽  
Sang Soo Park ◽  
Don Haeng Lee ◽  
Gyu Baek Lee ◽  
...  