Investigation on effect of indoor air distribution strategy on solar air-conditioning systems

2019 ◽  
Vol 131 ◽  
pp. 413-421 ◽  
Author(s):  
K.F. Fong ◽  
C.K. Lee ◽  
Z. Lin
2019 ◽  
Vol 11 (4) ◽  
pp. 1036 ◽  
Author(s):  
Beom-Jun Kim ◽  
Junseok Park ◽  
Jae-Weon Jeong

The main objective of this study is to investigate the indoor air quality enhancement performance of two different liquid desiccant and evaporative cooling-assisted air conditioning systems, such as the variable air volume (VAV) system with the desiccant-enhanced evaporative (DEVap) cooler, and the liquid desiccant system with an indirect and direct evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS), compared with the conventional VAV system. The transient simulations of concentration variations of carbon dioxide (CO2), coarse particles, and fine particles (PM10 and PM2.5) in a model office space served by each system were performed using validated system models that were found in the literature. Based on the hourly thermal loads of the model space predicted by the TRNSYS 18 program, each air conditioning system was operated virtually using a commercial equation solver program (EES). The results indicated that the LD-IDECOAS provided the lowest annual indoor CO2 concentration among all the systems considered in this research, while the VAV system with DEVap cooler exceeded the threshold concentration (i.e., 1000 ppm) during the cooling season (i.e., July, August, and September). For the indoor particulate contaminant concentrations, both liquid desiccant and evaporative cooling-assisted air conditioning systems indicated lower indoor PM2.5 and PM10 concentrations compared with the reference system. The LD-IDECOAS and the VAV with a DEVap cooler demonstrated 33.3% and 23.5% lower annual accumulated indoor PM10 concentrations than the reference system, respectively. Similarly, the annual accumulated indoor PM2.5 concentration was reduced by 16% using the LD-IDECOAS and 17.1% using the VAV with DEVap cooler.


2019 ◽  
Vol 7 (12) ◽  
pp. 674
Author(s):  
Xavier Libert ◽  
Camille Chasseur ◽  
Ann Packeu ◽  
Fabrice Bureau ◽  
Nancy H. Roosens ◽  
...  

Today, indoor air pollution is considered a public health issue. Among the impacting pollutants, indoor airborne fungi are increasingly highlighted. Most of the monitoring protocols are culture-based, but these are unable to detect the uncultivable and/or dead fraction or species suppressed by fast-growing fungi, even though this fraction could impact health. Among the contaminants suspected to be part of this fraction, Exophiala jeanselmei is an interesting case study. Known to be pathogenic, this black yeast grows in humid environments such as air-conditioning systems, where it has been previously detected using classical culture-based methods. However, until now, this fungus was never detected in indoor air in contact with these air-conditioning systems. This study shows the first detection of E. jeanselmei in indoor air collected from offices in contact with contaminated air-conditioning reservoirs. While its presence in indoor air could not be demonstrated with culture-based methods, it was found by real-time PCR and massive parallel sequencing. The latter also allowed obtaining a broader view on the fungal diversity in the tested samples. Similar approaches were applied on water samples collected from the conditioning reservoirs to trace the source of contamination. The comparison of results obtained with both methods confirmed that the molecular tools could improve indoor air monitoring, especially of dead and/or uncultivable contaminants or when competition between species could occur.


2014 ◽  
Vol 716-717 ◽  
pp. 1002-1005
Author(s):  
Heng Luo ◽  
Lu Gao ◽  
Xiao Yan Ye ◽  
Tong Jing ◽  
Ning Wang ◽  
...  

Indoor air quality has become a major concern in the past three decades due to the air-tight structure design and usage of synthetic building materials. A number of measures have been presented in order to improve the indoor air conditions via ventilation and air conditioning systems. We distinguished ourselves by adopting a self-managed plant based method in which a mini-car is used to carry vegetation to places where air conditions are poor.


Sign in / Sign up

Export Citation Format

Share Document