Simultaneous determination of cobalt and palladium in micellar media using H-point standard addition method and partial least square regression

Author(s):  
G. Bagherian ◽  
M. Arab Chamjangali ◽  
H. Eskandari
2012 ◽  
Vol 9 (1) ◽  
pp. 224-232
Author(s):  
Amandeep Kaur ◽  
Usha Gupta

H-point standard addition method (HPSAM) is developed for simultaneous determination of eosin-Yand ponceau-s in micellar media. Nickel chloride (NiCl2) is used as chromogenic reagent for complexes formation of eosin-Yand ponceau-Sfood colorants. The measurements were carried out using sodium lauryl sulphate as a surfactant, in buffered solution at pH 6.0. The concentration range of 0.115-2.53 μg/mL of eosin-Yand 0.159-3.80 μg/mL of ponceau-S. The proposed procedures have been applied successfully for the simultaneous determination of eosin-Yand ponceau-Sin synthetic binary mixtures and real samples.


2011 ◽  
Vol 8 (4) ◽  
pp. 1979-1985 ◽  
Author(s):  
Amandeep Kaur ◽  
Usha Gupta

A new, simple, sensitive and selectiveH-point standard addition method (HPSAM) has been developed for resolving binary mixture of food colorants eosin and erythrosine, which show overlapped spectra. The method is based on the complexation of food dyes eosin and erythrosine with Fe(III) complexing reagent at pH 5.5 and solubilizing complexes in triton x-100 micellar media. Absorbances at the two pairs of wavelengths, 540 and 550 nm (when eosin acts as analyte) or 518 and 542 nm (when erythrosine act as analyte) were monitored. This method has satisfactorily been applied for the determination of eosin and erythrosine dyes in synthetic mixtures and commercial products.


2009 ◽  
Vol 63 (3) ◽  
Author(s):  
Maryam Bordbar ◽  
Ali Yeganeh-Faal ◽  
Jahanbakhsh Ghasemi ◽  
Mohammad Ahari-Mostafavi ◽  
Nahid Sarlak ◽  
...  

AbstractA simple, sensitive and selective spectrophotometric method for simultaneous determination of tretinoin and minoxidil using partial least square (PLS) calibration and H-point standard addition method (HPSAM) is described. The results of the H-point standard addition method show that minoxidil and tretinoin can be determined simultaneously with the concentration ratio of tretinoin to minoxidil varying from 2: 1 to 1: 33 in mixed samples. A partial least squares multivariate calibration method for the analysis of binary mixtures of tretinoin and minoxidil was also developed. The total relative standard error for applying the PLS method to eleven synthetic samples in the concentration range of 0–10 μg mL−1 tretinoin and 0–32 μg mL−1 minoxidil was 2.59 %. Both proposed methods (PLS and HPSAM) were also successfully applied in the determination of tretinoin and minoxidil in several synthetic pharmaceutical solutions.


Sign in / Sign up

Export Citation Format

Share Document