Ultraviolet spectrophotometry (dual wavelength and chemometric) and high performance liquid chromatography for simultaneous estimation of meropenem and sulbactam sodium in pharmaceutical dosage form

Author(s):  
Kuldip R. Marwada ◽  
Jigar B. Patel ◽  
Nisarg S. Patel ◽  
Bhargav D. Patel ◽  
Dharnant V. Borkhatariya ◽  
...  
INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (01) ◽  
pp. 35-40
Author(s):  
A. S. Bagde ◽  
V. V. Khanvilkar ◽  

The present work describes a validated reverse phase high performance liquid chromatography (RPHPLC) method for simultaneous estimation of dextromethorphan hydrobromide and quinidine sulphate in pharmaceutical dosage from. The drugs were resolved using Hemochrom Intsil C18-5U column (250×4.6) mm in isocratic mode with mobile phase methanol: water (0.08% diethylamine, 0.02% of glacial acetic acid and pH 4.4 adjusted with orthophosphoric acid) in the ratio of 70:30 V/V at a flow rate of 1.0 mL/min. Retention time of dextromethorphan hydrobromide and quinidine sulphate were 4.9±0.2 and 3.6±0.2, respectively, at 292nm. The above mentioned method was validated as per International Conference on Harmonization (ICH) guidelines. Linear responses were obtained in concentration ranges of 5-35 μg/mL for dextromethorphan hydrobromide and 4-16 μg/mL for quinidine sulphate, with correlation coefficient (r2) of 0.999 for both the drugs. A simple, selective, accurate, precise, robust and reliable RP-HPLC method thus developed and validated for simultaneous estimation of dextromethorphan hydrobromide and quinidine sulphate.


2019 ◽  
Vol 6 (2) ◽  
pp. 95
Author(s):  
Fikri Alatas ◽  
Hernandi Sujono ◽  
Woro Artati Sucipto

<p align="center"><strong>Abstrak</strong><strong></strong></p><p align="center"><strong> </strong></p><p>Metode kromatografi cair kinerja tinggi (KCKT) dengan detektor ultra lembayung telah dikembangkan dan divalidasi untuk estimasi kadar secara simultan campuran piridoksin hidroklorida (PH) dan piratiazin teoklat (PT)dalam sediaan tablet antiemetik. Proses pemisahan terjadi dalam kolom Inertsil® ODS-3 pada panjang gelombang 280 nm dengan laju alir 1,0 mL/menit. Fase gerak yang optimal untuk pemisahan adalah campuran methanol-asam asetat 1% (20:80) dengan waktu retensi PH dan PT berturut-turut adalah 1,2 dan 9,8 menit. Perolehan kembali PH dan PT berturut-turut adalah 100,13 dan 99,78 %. Batas deteksi untuk PH dan PT berturut-turut adalah 0,21 dan 0,22 µg/mL, sedangkan batas kuantisasinya berturut-turut adalah 0,70 dan  0,72 µg/mL. Metode ini dapat diterapkan sebagai metode untuk estimasi kadar campuran piridoksin hidroklorida dan piratiazin teoklat dalam bentuk sediaan tablet secara simultan.</p><p> </p><p><strong>Kata kunci:</strong> Piridoksin hidroklorida, piratiazin teoklat, KCKT, tablet</p><p> </p><p align="center"><strong><em>Development and validation of high performance liquid chromatography (HPLC) method for simultaneous estimation of antiemetic pyridoxyne hydrochloride and pyrathiazine theoclate in tablet dosage form</em></strong></p><p> </p><p align="center"><strong><em>Abstract</em></strong><strong><em></em></strong></p><p><em> </em></p><p><em>The high performance liquid chromatography (HPLC) method with an ultra violet detector has been developed and validated for simultaneous estimation of pyridoxine hydrochloride (PH) and pyrathiazine theoclate (PT) in antiemetic tablet preparations. The separation process occurs in the Inertsil® ODS-3 column at a wavelength of 280 nm with a flow rate of 1.0 mL /min. The optimal mobile phase for separation is a mixture of methanol-acetic acid 1% (20:80) with the retention times of PH and PT 1.2 and 9.8 minutes respectively. The recoveries of PH and PT were 100.13 and 99.78%, respectively. The detection limits for PH and PT were 0.21 and 0.22 µg / mL respectively, while the quantisation limits were 0.70 and 0.72 µg / mL, respectively. This method can be applied as a method for simultaneous estimating the levels of pyridoxine hydrochloride and pyrathiazine theoclate in tablet dosage form.</em><em></em></p><p><em> </em></p><p><strong><em>Keywords:</em></strong><em> Pyridoxine hydrochloride, pyrathiazine theoclate, HPLC, tablet</em></p>


Author(s):  
SRUTHI A ◽  
UTTAM PRASAD PANIGRAHY

Objective: A rapid, sensitive and specific reverse phase High performance liquid Chromatography (RP-HPLC) method was developed for the estimation of Fimasartan in bulk and pharmaceutical dosage form. Method: The RP-HPLC analysis was performed isocratically on a Primacel C18 column (150 mm × 4.6 mm internal diameter, 5 μm particle size) using mobile phase of composition Acetonitrile and 0.1% orthophosphoric Acid in 80:20, v/v proportions with a flow rate of 0.8 ml/min. Results: The analyte was monitered with UV-detector at 265 nm. In the developed method Fimasartan elutes at a typical retention time of 2.4 min. The proposed method is having linearity in the concentration ranging from 5-30 μg/ml of Fimasartan. Conclusion: : The method was statistically validated and had been applied to analysis of the drug in bulk and pharmaceutical dosage form.


Author(s):  
Geetha Susmita A ◽  
Rajitha G ◽  
Ramya Yadav Y ◽  
Uma P

Objective: The objective of this study was to develop and validate a stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of the metformin and empagliflozin in tablet dosage forms.Methods: The chromatographic conditions were optimized and it was run through Std. BDS (250 mm × 4.6 mm, 5 m) column with mobile phase consisting of 0.1% orthophosphoric acid buffer: acetonitrile in the ratio of 50:50. The flow rate was 1 ml/min and optimized wavelength was 210 nm. Temperature was maintained at 30°C.Results: The retention times of metformin and empagliflozin were found to be 2.588 min and 3.679 min and percentage relative standard deviation (RSD) of the metformin and empagliflozin was found to be 0.59 and 1.2, respectively. Percentage recovery was in the range of 100.01–100.65% for metformin and empagliflozin, respectively.Conclusion: A sensitive, rapid, and specific method has been developed for the simultaneous estimation of metformin and empagliflozin using RP-HPLC in tablet dosage form.


Author(s):  
Geetha Susmita A ◽  
Rajitha G ◽  
Ramya Yadav Y ◽  
Uma P

Objective: The objective of this study was to develop and validate a stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of the metformin and empagliflozin in tablet dosage forms.Methods: The chromatographic conditions were optimized and it was run through Std. BDS (250 mm × 4.6 mm, 5 m) column with mobile phase consisting of 0.1% orthophosphoric acid buffer: acetonitrile in the ratio of 50:50. The flow rate was 1 ml/min and optimized wavelength was 210 nm. Temperature was maintained at 30°C.Results: The retention times of metformin and empagliflozin were found to be 2.588 min and 3.679 min and percentage relative standard deviation (RSD) of the metformin and empagliflozin was found to be 0.59 and 1.2, respectively. Percentage recovery was in the range of 100.01–100.65% for metformin and empagliflozin, respectively.Conclusion: A sensitive, rapid, and specific method has been developed for the simultaneous estimation of metformin and empagliflozin using RP-HPLC in tablet dosage form.


Author(s):  
Venkateswara Rao P ◽  
Lakshmana Rao A ◽  
Prasad Svum

Objective: The present study deals with the development, validation, and application of simple, precise, and accurate high-performance liquid chromatography (HPLC) method for the simultaneous estimation of metformin hydrochloride and ertugliflozin in pharmaceutical formulation and to validate.Methods: The analytical conditions were optimized on BDS C8 column (150 mm × 4.6 mm, 5 μm) at room temperature. The mobile phase consists of buffer: acetonitrile in 55:45 v/v ratio. Injection volume was 10 μl. The flow rate was maintained at 1.0 ml/min, and the analysis was carried out at 224 nm.Results: The method was found to be linear in the concentration range of 125–750 μg/ml and 1.875–11.25 μg/ml for metformin hydrochloride and ertugliflozin with regression coefficient r2 = 0.999. The method was found to be precise with percentage relative standard deviation below 2%. The limit of detection and limit of quantification were found to be within the limits. The percentage recovery of the developed method was 100.15%. All the validation parameters such as robustness, recovery, and precision were found to be within the limits. Degradation parameters such as acid, base, thermal and peroxide, light, temperature, and humidity were performed and found that the drugs are stable in all the extreme conditions.Conclusions: A simple, accurate, precise, and less time-consuming reversed-phase HPLC method for the simultaneous estimation of metformin hydrochloride and ertugliflozin has been developed and validated in accordance with the ICH guidelines.


Sign in / Sign up

Export Citation Format

Share Document