scholarly journals Zebrafish larva’s response and habituation to electric signal: Effects of voltage, current and pulsation studied in a microfluidic device

2021 ◽  
Vol 332 ◽  
pp. 113070
Author(s):  
Arezoo Khalili ◽  
Ellen van Wijngaarden ◽  
Georg R. Zoidl ◽  
Pouya Rezai
Micromachines ◽  
2021 ◽  
Vol 12 (6) ◽  
pp. 662
Author(s):  
Nikita A. Filatov ◽  
Anatoly A. Evstrapov ◽  
Anton S. Bukatin

Droplet microfluidics is an extremely useful and powerful tool for industrial, environmental, and biotechnological applications, due to advantages such as the small volume of reagents required, ultrahigh-throughput, precise control, and independent manipulations of each droplet. For the generation of monodisperse water-in-oil droplets, usually T-junction and flow-focusing microfluidic devices connected to syringe pumps or pressure controllers are used. Here, we investigated droplet-generation regimes in a flow-focusing microfluidic device induced by the negative pressure in the outlet reservoir, generated by a low-cost mini diaphragm vacuum pump. During the study, we compared two ways of adjusting the negative pressure using a compact electro-pneumatic regulator and a manual airflow control valve. The results showed that both types of regulators are suitable for the stable generation of monodisperse droplets for at least 4 h, with variations in diameter less than 1 µm. Droplet diameters at high levels of negative pressure were mainly determined by the hydrodynamic resistances of the inlet microchannels, although the absolute pressure value defined the generation frequency; however, the electro-pneumatic regulator is preferable and convenient for the accurate control of the pressure by an external electric signal, providing more stable pressure, and a wide range of droplet diameters and generation frequencies. The method of droplet generation suggested here is a simple, stable, reliable, and portable way of high-throughput production of relatively large volumes of monodisperse emulsions for biomedical applications.


Author(s):  
Arezoo Khalili ◽  
Ellen van Wijngaarden ◽  
khaled Youssef ◽  
Georg Zoidl ◽  
Pouya Rezai

Microfluidic devices have been introduced for phenotypic screening of zebrafish larvae in both fundamental and pre-clinical research. One of the remaining challenges for the broad use of microfluidic devices is their limited throughput, especially in behavioural assays. Previously, we introduced the tail locomotion of a semi-mobile zebrafish larva evoked on-demand with electric signal in a microfluidic device. Here, we report the lessons learned for increasing the number of specimens from one to four larvae in this device. Multiple parameters including loading and testing time per fish and loading and orientation efficiencies were refined to optimize the performance of modified designs. Simulations of the flow and electric field within the final device provided insight into the flow behavior and functionality of traps when compared to previous single-larva devices. Outcomes led to a new design which decreased the testing time per larva by approximately 60%. Further, loading and orientation efficiencies increased by more than 80%. Critical behavioural parameters such as response duration and tail beat frequency were similar in both single and quadruple-fish devices. The optimized microfluidic device has significant advantages for greater throughput and efficiency when behavioral phenotyping is required in various applications, including chemical testing in toxicology and gene screening.


Author(s):  
Arezoo Khalili ◽  
Ellen van Wijngaarden ◽  
Georg Zoidl ◽  
Pouya Rezai

We previously showed that electric current can cause zebrafish larvae to move towards the anode pole along a microchannel. For a semi-mobile larva, we observed that zebrafish response to electricity depended on the current magnitude. The effects of electric signal direction, voltage magnitude and habituation to repeated exposures to electric pulses were not characterized. Here, this knowledge gap was addressed by exploiting these parameters in a microfluidic device with a head-trap to immobilize a zebrafish larva and a downstream chamber for tail movement and phenotypic characterization of response duration (RD) and tail beat frequency (TBF). We first assessed larvae’s response to electric current direction (at 3µA) and voltage magnitude. Changing the current direction significantly altered the RD and TBF with long and low-frequency responses seen when the anode was positioned at larvae’s tail. The electric voltage drop across the fish body had a significant effect on larvae’s locomotion with long RD and low TBF observed at 5.6V in the range of 1.3-9V. We also demonstrated that the zebrafish locomotor response to repeated 3µA current pulses diminished with dependency on the interstimulus interval. However, the diminished response was fully recovered after a 5-min resting period or introduction of a novel light stimulus (i.e. habituation-dishabituation strategy). Therefore, electric response suppression in zebrafish was attributed to the habituation as a form of non-associative learning. Our microfluidic platform has broad application potential in behavioral neuroscience to study cognitive phenotypes, fundamental studies on the biological roots of electric response, and pharmacological screening.


2019 ◽  
Vol 139 (7) ◽  
pp. 209-216
Author(s):  
Jiaxu Wu ◽  
Yoshikazu Hirai ◽  
Ken-ichiro Kamei ◽  
Toshiyuki Tsuchiya ◽  
Osamu Tabata

2016 ◽  
Vol 136 (9) ◽  
pp. 384-389
Author(s):  
Kazuya Fujimoto ◽  
Hirofumi Shintaku ◽  
Hidetoshi Kotera ◽  
Ryuji Yokokawa

2003 ◽  
Vol 773 ◽  
Author(s):  
Myung-Il Park ◽  
Jonging Hong ◽  
Dae Sung Yoon ◽  
Chong-Ook Park ◽  
Geunbae Im

AbstractThe large optical detection systems that are typically utilized at present may not be able to reach their full potential as portable analysis tools. Accurate, early, and fast diagnosis for many diseases requires the direct detection of biomolecules such as DNA, proteins, and cells. In this research, a glass microchip with integrated microelectrodes has been fabricated, and the performance of electrochemical impedance detection was investigated for the biomolecules. We have used label-free λ-DNA as a sample biomolecule. By changing the distance between microelectrodes, the significant difference between DW and the TE buffer solution is obtained from the impedance-frequency measurements. In addition, the comparison for the impedance magnitude of DW, the TE buffer, and λ-DNA at the same distance was analyzed.


2002 ◽  
Author(s):  
Min Yue ◽  
Katherine Dunphy ◽  
Jerry Jenkins ◽  
Christopher Dames ◽  
Guanghua Wu ◽  
...  

Diabetes ◽  
2019 ◽  
Vol 68 (Supplement 1) ◽  
pp. 101-LB
Author(s):  
ABHINAV BHUSHAN ◽  
SONALI J. KARNIK

Sign in / Sign up

Export Citation Format

Share Document