Performance assessment of a desiccant air-conditioning system combined with dew-point indirect evaporative cooler and PV/T

Solar Energy ◽  
2022 ◽  
Vol 231 ◽  
pp. 566-577
Author(s):  
Umutcan Olmuş ◽  
Yunus Emre Güzelel ◽  
Engin Pınar ◽  
Arif Özbek ◽  
Orhan Büyükalaca
2019 ◽  
Vol 111 ◽  
pp. 02021
Author(s):  
Djallel Abada ◽  
Chadi Maalouf ◽  
Tala MOUSSA ◽  
Amel Ferial Boudjabi ◽  
Guillaume Polidori ◽  
...  

Refreshing air remains a crucial problem in warm climates where electricity consumption for air conditioning has become excessive and irrational for several years, notably in Algeria. Research in this field is increasingly oriented towards new techniques that can reduce costs and environmental impacts. Among these techniques, the evaporative dew point cooling technology is the most promising as it can cool outdoor air to temperatures below its wet bulb temperature. The aim of this work is to model and design a dew point cooler for french and algerian climates. This model is used to study the effect of the cooler parameters such as its length, water temperature and working air ratio on its cooling effectiveness and supply temperature.


2014 ◽  
Vol 628 ◽  
pp. 332-337
Author(s):  
Xiao Xia Xia ◽  
Nai Jun Zhou ◽  
Zhi Qi Wang

The energy consumption of several central air conditioning systems in summer was researched by the method of exergy analysis. Combined with actual example,the exergy loss of all the equipments and the exergy efficiency of three systems were calculated. The results show that the exergy efficiency of three systems is very low. Relatively speaking, the exergy efficiency of primary return air conditioning system with supplying air in dew point is highest. The equipment of highest exergy loss is air-conditioned room, while the exergy loss of surface air cooler is smallest. Based on this, several improvement measures were proposed to reduce exergy loss and improve exergy efficiency.


Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 522
Author(s):  
Su Liu ◽  
Jae-Weon Jeong

This study investigated the annual energy saving potential and system performance of two different evaporative cooling-based liquid desiccant and evaporative cooling-assisted air conditioning systems. One system used an indirect and direct evaporative cooler with a two-stage package to match the target supply air point. The other was equipped with a single-stage, packaged dew-point evaporative cooler that used a portion of the process air, which had been dehumidified in advance. Systems installed with the two evaporative coolers were compared to determine which one was more energy efficient and which one could provide better thermal comfort for building occupants in a given climate zone, using detailed simulation data. The detailed energy consumption data of these two systems were estimated using an engineering equation solver with each component model. The results showed that the liquid desiccant and dew-point evaporative-cooler-assisted 100% outdoor air system (LDEOAS) resulted in approximately 34% more annual primary energy consumption than that of the liquid desiccant and the indirect and direct evaporative-cooler-assisted 100% outdoor air system (LDIDECOAS). However, the LDEOAS could provide drier and cooler supply air, compared with the LDIDECOAS. In conclusion, LDIDECOAS has a higher energy saving potential than LDEOAS, with an acceptable level of thermal comfort.


Author(s):  
Stefano Bergero ◽  
Anna Chiari ◽  
Enrico Nannei

The present study examines the performance of a hybrid air-conditioning system in which a vapour compression inverse cycle is integrated with an air dehumidification system working with hygroscopic solution and hydrophobic membrane. This approach may prove to be a valid alternative to the traditional summertime air-conditioning system, which involves cooling the air to below its dew point and subsequently reheating it. The system examined simultaneously cools and dehumidifies the air in an air-LiCl solution membrane vapour exchanger before it enters the conditioned environment. The LiCl solution is cooled by means of a vapour compression inverse cycle that uses the refrigerant KLEA 407C. The heat rejected by the condenser is used to regenerate the solution. A SIMULINK calculation programme was used to simulate the system in steady-state conditions. The performance of the system was analysed on varying significant operating parameters and was compared with that of a traditional direct-expansion air-conditioning plant. The results of the simulations revealed significant power saving which, in certain operating conditions, was as much as 50%.


Sign in / Sign up

Export Citation Format

Share Document