scholarly journals Meta-Analysis: Contrast-Enhanced Ultrasound Versus Conventional Ultrasound for Differentiation of Benign and Malignant Breast Lesions

2018 ◽  
Vol 44 (5) ◽  
pp. 919-929 ◽  
Author(s):  
Qian Li ◽  
Min Hu ◽  
Zhikui Chen ◽  
Changtian Li ◽  
Xi Zhang ◽  
...  
2015 ◽  
Vol 56 (1) ◽  
pp. 25-33 ◽  
Author(s):  
Qiao Hu ◽  
Xiao Yan Wang ◽  
Shang Yong Zhu ◽  
Li Ke Kang ◽  
Yan Ju Xiao ◽  
...  

2021 ◽  
Vol 49 (5) ◽  
pp. 030006052110106
Author(s):  
Shanhong Lin ◽  
Yong Cao ◽  
Libin Chen ◽  
Mei Chen ◽  
Shengmin Zhang ◽  
...  

We herein present a rare case of breast fibromatosis, the contrast-enhanced ultrasonography (CEUS) findings of which we believe have never been described. The high similarity between the clinical and imaging manifestations of breast cancer makes its differential diagnosis difficult. In this report, we describe the CEUS findings of a less common type of fibromatosis, discuss the potential value of CEUS to differentiate it from malignant breast lesions, and briefly review the literature.


2020 ◽  
Vol 19 ◽  
pp. 153303382097158
Author(s):  
Jianghao Lu ◽  
Peng Zhou ◽  
Chunchun Jin ◽  
Lifeng Xu ◽  
Xiaomin Zhu ◽  
...  

Purpose: A meta-analysis was conducted to evaluate the diagnostic performance of contrast-enhanced ultrasonography using the contrast agent SonoVue to differentiate benign from malignant breast lesions. Method: A comprehensive search of the literature was performed using the Embase, PubMed, and Web of Science databases to retrieve studies published before February 2020. Data were extracted, and pooled sensitivity, specificity, and diagnostic odds ratios were calculated with meta-analysis software. Heterogeneity was evaluated via the Q test and I2 statistic. Meta-regression and subgroup analyses were applied to evaluate potential sources of heterogeneity. Publication bias was assessed using the Deeks’ funnel plot asymmetry test. A summary receiver operating characteristic curve (SROC) was constructed. Results: A total of 27 studies including 5378 breast lesions subjected to CEUS examination with SonoVue were included in the meta-analysis. The pooled sensitivity and specificity values were 0.90 (95% confidence interval [CI], 0.88–0.91; inconsistency index [ I2] = 75.7%) and 0.83 (95% CI, 0.82–0.85; I2 = 91.0%), respectively. The pooled diagnostic odds ratio was 48.35% (95% CI, 31.22–74.89; I2 = 77.6%). The area under the summary receiver operating characteristic curve (AUC) was 0.9354. Meta-regression analysis revealed the region of patient residence and dose of contrast agent as potential sources of heterogeneity (P < .01). Subgroup analysis showed a higher area under the summary receiver operating characteristic curve for European and higher contrast agent dose subgroups (P < .05). Conclusion: Contrast-enhanced ultrasonography with SonoVue displays high sensitivity, specificity, and accuracy when differentiating benign from malignant breast lesions. Despite its current limitations, this technique presents a promising tool for diagnosing breast lesions in clinical practice.


Sign in / Sign up

Export Citation Format

Share Document