contrast enhanced ultrasonography
Recently Published Documents


TOTAL DOCUMENTS

1148
(FIVE YEARS 220)

H-INDEX

42
(FIVE YEARS 6)

2022 ◽  
Author(s):  
Yue Zhang ◽  
Qin Wang ◽  
Chun-yan Gao ◽  
Hong-ju Tian ◽  
jiao He ◽  
...  

Abstract Background To investigate the safety and effectiveness of tubal inflammatory drugs in patients with incomplete tubal obstruction of at least 1 side after four-dimensional hysterosalpingo-contrast-sonography (4D-HyCoSy) examination. Methods 215 cases of tubal insufficiency were diagnosed by ultrasonography from February 2019 to November 2020.According to retrospective analysis,the patients in this study were divided into experimental and control groups; the experimental group was treated with a push of salpingitis drugs, and the control group received blank control. Basic information, degree of pain, postoperative complications, and pregnancy rate were then compared between the 2 groups. Result(s) : Compared with the control group, there was no significant difference in the basic information; preoperative, intraoperative, or postoperative pain; or in postoperative complications (P > 0.05). The cumulative pregnancy rate of the experimental group (28.0%) was statistically different from that of the control group (15.3%) (P < 0.05). Conclusion(s): We observed that for infertile patients with incomplete obstruction of at least one fallopian tube as diagnosed by contrast-enhanced ultrasonography, salpingitis-treatment drugs effectively improved the pregnancy rate postoperatively, with high effectiveness and safety. This regimen is thus worthy of further investigation and promotion in the future.


2022 ◽  
Vol 39 (1) ◽  
pp. 155-161
Author(s):  
Zu-Bang Zhou ◽  
Ya-E Xue ◽  
Yan-Wu Yao ◽  
Xue-Ting Zhang ◽  
Ming-Hua Zhang ◽  
...  

Author(s):  
Gang Zhang ◽  
Dandan Liu

BACKGROUND: To investigate the accuracy of contrast-enhanced ultrasonography, CT-enhancement and MRI in the diagnosis of liver-occupying lesions. METHODS: 176 patients with suspected liver lesions in our hospital were retrospectively studied from July 2014 to July 2016. All of the 176 patients were diagnosed by contrast-enhanced ultrasonography, enhanced CT and MRI, and the pathological examination was performed. The results of pathological examination were regarded as the results of the diagnosis. The diagnostic accuracywas then compared among contrast-enhanced ultrasound, enhanced CT and MRI of these patients. RESULTS: The results of contrast-enhanced ultrasonography showed that 164 of the 176 patients had liver-occupying lesions, and the accuracy of the diagnosis was 95.35%, which was significantly higher than that of CT enhancement and MRI (80.23% 84.30%). The accuracy of contrast-enhanced ultrasonography, in the diagnosis of primary liver cancer was significantly higher than that of CT enhancement and MRI (P <  0.05), and the difference was significant difference (P <  0.05). CONCLUSIONS: The examination of contrast-enhanced ultrasonography is relatively simple, and the patients can get duplicateexamination, so we should choose the contrast-enhanced ultrasonography as the preferred method of diagnosis in liver mass, especially primary liver cancer.


2021 ◽  
Vol 2021 ◽  
pp. 1-12
Author(s):  
Ling Guo

This paper aims to explore the application value of SonoVue contrast-enhanced ultrasonography based on deep unsupervised learning (DNS) in the diagnosis of nipple discharge. In this paper, a new model (ODNS) is proposed based on the unsupervised learning model and stack self-coding network. The ultrasonic images of 1,725 patients with breast lesions in the shared database are used as the test data of the model. The differences in accuracy (Acc), recall (RE), sensitivity (Sen), and running time between the two models before and after optimization and other algorithms are compared. A total of 48 female patients with nipple discharge are enrolled. The differences in SE, specificity (SP), positive predictive value (PPV), and negative predictive value (NPV) of conventional ultrasound and contrast-enhanced ultrasonography are analyzed based on pathological examination results. The results showed that when the number of network layers is 5, the classification accuracies of DNS and ODNS model data reached the highest values, which were 91.45% and 98.64%, respectively.


BMJ Open ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. e052830
Author(s):  
Lizhang Xun ◽  
Lamei Zhai ◽  
Hui Xu

ObjectivesTo assess the value of conventional, Doppler and contrast-enhanced ultrasonography (CEUS) (conventional ultrasonography (US), Doppler US and CEUS) for diagnosing ovarian cancer.DesignSystematic review and meta-analysis.Data sourcesPubMed, Embase and the Cochrane Library were conducted for studies published until October 2021.Eligibility criteriaStudies assessed the diagnostic value of conventional US, Doppler US or CEUS for detecting ovarian cancer, with no restrictions placed on published language and status.Data extraction and synthesisThe study selection and data extraction were performed by two independent authors. The sensitivity, specificity, positive and negative likelihood ratio (PLR and NLR), diagnostic OR (DOR) and area under the receiver operating characteristic curve (AUC) were pooled using the bivariate generalised linear mixed model and random effects model.ResultsThe meta-analysis included 72 studies and involved 9296 women who presented with ovarian masses. The pooled sensitivity, specificity, PLR, NLR, DOR and AUC for conventional US were 0.91 (95% CI: 0.87 to 0.94) and 0.87 (95% CI: 0.82 to 0.91), 6.87 (95% CI: 4.98 to 9.49) and 0.10 (95% CI: 0.07 to 0.15), 57.52 (95% CI: 36.64 to 90.28) and 0.95 (95% CI: 0.93 to 0.97), respectively. The sensitivity, specificity, PLR, NLR, DOR and AUC for Doppler US were 0.93 (95% CI: 0.91 to 0.95) and 0.85 (95% CI: 0.80 to 0.89), 6.10 (95% CI: 4.59 to 8.11) and 0.08 (95% CI: 0.06 to 0.11), 61.76 (95% CI: 39.99 to 95.37) and 0.96 (95% CI: 0.94 to 0.97), respectively. The pooled sensitivity, specificity, PLR, NLR, DOR and AUC for CEUS were 0.97 (95% CI: 0.92 to 0.99) and 0.92 (95% CI: 0.85 to 0.95), 11.47 (95% CI: 6.52 to 20.17) and 0.03 (95% CI: 0.01 to 0.09), 152.11 (95% CI: 77.77 to 297.51) and 0.99 (95% CI: 0.97 to 0.99), respectively. Moreover, the AUC values for conventional US (p=0.002) and Doppler US (p=0.005) were inferior to those of CEUS.ConclusionsConventional US, Doppler US and CEUS have a relatively high differential diagnostic value for differentiating between benign and malignant ovarian masses. The diagnostic performance of CEUS was superior to that of conventional US and Doppler US.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Zhe Huang ◽  
Jun-yi Xin ◽  
Kai-yan Li

Abstract Background An angiomyolipoma usually occurs in the kidneys and rarely in the liver. Hepatic epithelioid angiomyolipoma (HEAML), a rare variant of angiomyolipoma, possesses malignant potential and mimics the imaging features of hepatocellular carcinoma. Sonazoid® (perfluorobutane microbubbles), a new contrast agent that facilitates hepatic parenchyma-specific Kupffer phase imaging on contrast-enhanced ultrasonography (CEUS), is useful for the detection and characterization of focal liver lesions. Case presentation A 30-year-old man with HEAML underwent CEUS using Sonazoid®, in which new concepts for ultrasonography-based differentiation between HEAML and hepatocellular carcinoma were applied. Conclusions This case report provides clinicians and radiologists with a reference for distinguishing HEAML from hepatocellular carcinoma based on CEUS using Sonazoid®.


Diagnostics ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 2232
Author(s):  
Adriana Ciocalteu ◽  
Sevastita Iordache ◽  
Sergiu Marian Cazacu ◽  
Cristiana Marinela Urhut ◽  
Sarmis Marian Sandulescu ◽  
...  

Clinical utility of ancillary features (AFs) in contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS®) is yet to be established. In this study, we assessed the diagnostic yield of CEUS LI-RADS and AFs in hepatocellular carcinoma (HCC). We retrospectively included patients with risk factors for HCC and newly diagnosed focal liver lesions (FLL). All lesions have been categorized according to the CEUS LI-RADS v2017 by an experienced sonographer blinded to clinical data and to the final diagnosis. From a total of 143 patients with 191 FLL, AFs favoring HCC were observed in 19.8% cases as hypoechoic rim and in 16.7% cases as nodule-in nodule architecture. From the total of 141 HCC cases, 83.6% were correctly classified: 57.4%- LR-5 and 26.2%- LR-4. In 9.21% cases, CEUS indicated LR-M; 2.12% cases- LR-3. The LR-5 category was 96.2% predictive (PPV) of HCC. LR-5 had 60.4% sensitivity and 93.6% specificity. PPV for primitive malignancy (LR-4 + LR-5) was 95.7%, with 88% sensitivity, 89.3% specificity and 88.4% accuracy for HCC. LR-4 category had 94.8% PPV and 26.2% sensitivity. CEUS LR4 + LR5 had 81,8% sensitivity for HCCs over 2 cm and 78.57% sensitivity for smaller HCCs. CEUS LR-5 remains an excellent diagnostic tool for HCC, despite the size of the lesion. The use of AFs might improve the overarching goal of LR-5 + LR-4 diagnosis of high specificity for HCC and exclusion of non-HCC malignancy.


2021 ◽  
Vol 8 ◽  
Author(s):  
Jiahui Liu ◽  
Zhi Wang ◽  
Ying Yang ◽  
Yan Xiong ◽  
Wei Wang ◽  
...  

Background: Primary pericardial mesothelioma is an extremely rare tumor, and early identification and accurate diagnosis may improve its clinical outcome.Case presentation: In this study, we reported a case of a 70-year-old woman who presented with dyspnea. Conventional transthoracic echocardiography showed massive pericardial effusion. Contrast-enhanced ultrasonography revealed a hyper-enhancing mass in the pericardium. Further imaging methods, including cardiac MRI and positron emission tomography/computed tomography, showed invasion of the pericardial mass into the adjacent tissues and distant metastases. Pathologic examination of a puncture biopsy specimen finally confirmed the diagnosis of PPM.Conclusion: Pericardial masses are difficult to detect when a large amount of pericardial effusion is present and the mass is small. The combination of multiple modalities plays a meaningful role in identifying PPM.