scholarly journals Effects of hydraulically disconnecting consumer pumps in an intermittent water supply

2021 ◽  
pp. 100107
Author(s):  
DavidD.J. Meyer ◽  
J. Khari ◽  
Andrew J. Whittle ◽  
Alexander H. Slocum
Author(s):  
Husnain Haider ◽  
Mohammed Hammed Alkhowaiter ◽  
M. D. Shafiquzzaman ◽  
Mohammad Alresheedi ◽  
Saleem S. AlSaleem ◽  
...  

2016 ◽  
Vol 76 (4) ◽  
pp. 1492-1514 ◽  
Author(s):  
Anna M. Lieb ◽  
Chris H. Rycroft ◽  
Jon Wilkening

Water ◽  
2020 ◽  
Vol 12 (3) ◽  
pp. 806
Author(s):  
Takuya Sakomoto ◽  
Mahmood Lutaaya ◽  
Edo Abraham

Intermittent water supply networks risk microbial and chemical contamination through multiple mechanisms. In particular, in the cities of developing countries, where intrusion through leaky pipes are more prevalent and the sanitation systems coverage is low, contaminated water can be a public health hazard. Although countries using intermittent water supply systems aim to change to continuous water supply systems—for example, Kampala city is targeting to change to continuous water supply by 2025 through an expansion and rehabilitation of the pipe infrastructure—it is unlikely that this transition will happen soon because of rapid urbanisation and economic feasibility challenges. Therefore, water utilities need to find ways to supply safe drinking water using existing systems until gradually changing to a continuous supply system. This study describes solutions for improving water quality in Mukono town in Uganda through a combination of water quality monitoring (e.g., identifying potential intrusion hotspots into the pipeline using field measurements) and interventions (e.g., booster chlorination). In addition to measuring and analyses of multiple chemical and microbial water quality parameters, we used EPANET 2.0 to simulate the water quality dynamics in the transport pipeline to assess the impact of interventions.


2019 ◽  
Vol 55 (7) ◽  
pp. 5217-5237 ◽  
Author(s):  
David D. J. Taylor ◽  
Alexander H. Slocum ◽  
Andrew J. Whittle

2014 ◽  
Vol 960-961 ◽  
pp. 394-398
Author(s):  
Guang Hua Li ◽  
Qun Feng Yang

A new non-pressure waste heat recycling system was designed and arranged on KHSS0.5-0.7-AⅡ industrial coal-fired boiler to decrease the exhausted gas temperature about 35°C, improve the boiler efficiency about 3.2%. Results showed that this system can avoid low-temperature sulfur corrosion and operate in normal and intermittent water supply condition safely and economically.