Non-Pressure Heater Utilization on Low-Capacity Industrial Boiler

2014 ◽  
Vol 960-961 ◽  
pp. 394-398
Author(s):  
Guang Hua Li ◽  
Qun Feng Yang

A new non-pressure waste heat recycling system was designed and arranged on KHSS0.5-0.7-AⅡ industrial coal-fired boiler to decrease the exhausted gas temperature about 35°C, improve the boiler efficiency about 3.2%. Results showed that this system can avoid low-temperature sulfur corrosion and operate in normal and intermittent water supply condition safely and economically.

2013 ◽  
Vol 448-453 ◽  
pp. 2777-2780 ◽  
Author(s):  
Yan Feng Liu ◽  
Shi Ping Li ◽  
Xiang Hong Li

A 215MW cogeneration B&W670/13.7-M type high-pressure natural circulation boilers, the exhaust gas temperature is set as 143 °C, while in the actual operation, the average exhaust gas temperature is 155 °C, and when the unit is running at full capacity in summer the highest exhaust gas temperature is 169.6 °C. In order to satisfy the normal operating temperature of bag filter in summer peak load, and recover low temperature waste heat of fule gas, low temperature economizer is added to the thermal system. Therefore, low-temperature economizers are respectively added in four flues which are between the outlet of the air preheater and the entrance of the bag filter, this will achieve the purpose of reducing flue gas temperature by transferring heat between condensate and flue gas, ensuring the units safe operating and improving the overall operating performance of the boiler.


2021 ◽  
Vol 271 ◽  
pp. 01022
Author(s):  
Qiudong Hu

At present, the exhaust gas temperature of coal-fired power plants is 125-150℃, and the emission of high-temperature flue gas causes the loss of excess heat and wastes. For this kind of phenomenon, the waste heat recovery system is researched and designed, combined with the combination of a low-temperature economizer in a coal-fired power plant in Dezhou. The heater, through the low-temperature economizer combined with the heater system, reduces coal consumption for power generation, reduces flue gas emissions, while reducing dust specific resistance, improving dust removal efficiency of electric dust removal, and reducing dust emissions. This project responds to national policy guidelines.


Author(s):  
Koichi Nakaso ◽  
Erfina Oktariani ◽  
Atsushi Noda ◽  
Kazuya Nakashima ◽  
Keisuke Tahara ◽  
...  

More reduction in energy consumption is requested to the industrial processes. In particular, large quantity of waste water at low temperature is released from chemical and steel processes. In this study, adsorption/desorption process of zeolite and water pair were selected to generate steam from water at low temperature. Contacting water liquid and zeolite directly, adsorption heat released from zeolite makes excess water evaporate. Basic experiments for adsorption/desorption process were carried out. First of all, adsorbents with different type were tested to find the candidate of the proposed system, and then suitable adsorbent was selected. From the basic adsorption experiment, generation of steam from the water liquid was confirmed by the proposed system. In the desorption process, hot dry gas was introduced to the adsorbent. The effect of gas temperature and its flow rate was investigated. The performance of the system was theoretically investigated based on overall heat and mass balances. As a result, the ratio of enthalpy of recovered steam of 140°C to input waste water of 80°C was around 6 when adsorption process was only considered. On the other hand, the ratio was 0.57 when waste heat was utilized for the desorption process. However if waste heat such as exhaust gas can be utilized for the desorption process, the ratio, that is, the efficiency would increase.


Energies ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 954 ◽  
Author(s):  
Hanne Kauko ◽  
Daniel Rohde ◽  
Armin Hafner

District heating enables an economical use of energy sources that would otherwise be wasted to cover the heating demands of buildings in urban areas. For efficient utilization of local waste heat and renewable heat sources, low distribution temperatures are of crucial importance. This study evaluates a local heating network being planned for a new building area in Trondheim, Norway, with waste heat available from a nearby ice skating rink. Two alternative supply temperature levels have been evaluated with dynamic simulations: low temperature (40 °C), with direct utilization of waste heat and decentralized domestic hot water (DHW) production using heat pumps; and medium temperature (70 °C), applying a centralized heat pump to lift the temperature of the waste heat. The local network will be connected to the primary district heating network to cover the remaining heat demand. The simulation results show that with a medium temperature supply, the peak power demand is up to three times higher than with a low temperature supply. This results from the fact that the centralized heat pump lifts the temperature for the entire network, including space and DHW heating demands. With a low temperature supply, heat pumps are applied only for DHW production, which enables a low and even electricity demand. On the other hand, with a low temperature supply, the district heating demand is high in the wintertime, in particular if the waste heat temperature is low. The choice of a suitable supply temperature level for a local heating network is hence strongly dependent on the temperature of the available waste heat, but also on the costs and emissions related to the production of district heating and electricity in the different seasons.


Proceedings ◽  
2020 ◽  
Vol 65 (1) ◽  
pp. 25
Author(s):  
Antonio Garrido Marijuan ◽  
Roberto Garay ◽  
Mikel Lumbreras ◽  
Víctor Sánchez ◽  
Olga Macias ◽  
...  

District heating networks deliver around 13% of the heating energy in the EU, being considered as a key element of the progressive decarbonization of Europe. The H2020 REnewable Low TEmperature District project (RELaTED) seeks to contribute to the energy decarbonization of these infrastructures through the development and demonstration of the following concepts: reduction in network temperature down to 50 °C, integration of renewable energies and waste heat sources with a novel substation concept, and improvement on building-integrated solar thermal systems. The coupling of renewable thermal sources with ultra-low temperature district heating (DH) allows for a bidirectional energy flow, using the DH as both thermal storage in periods of production surplus and a back-up heating source during consumption peaks. The ultra-low temperature enables the integration of a wide range of energy sources such as waste heat from industry. Furthermore, RELaTED also develops concepts concerning district heating-connected reversible heat pump systems that allow to reach adequate thermal levels for domestic hot water as well as the use of the network for district cooling with high performance. These developments will be demonstrated in four locations: Estonia, Serbia, Denmark, and Spain.


Author(s):  
Husnain Haider ◽  
Mohammed Hammed Alkhowaiter ◽  
M. D. Shafiquzzaman ◽  
Mohammad Alresheedi ◽  
Saleem S. AlSaleem ◽  
...  

2021 ◽  
Vol 13 (9) ◽  
pp. 5223
Author(s):  
Miriam Benedetti ◽  
Daniele Dadi ◽  
Lorena Giordano ◽  
Vito Introna ◽  
Pasquale Eduardo Lapenna ◽  
...  

The recovery of waste heat is a fundamental means of achieving the ambitious medium- and long-term targets set by European and international directives. Despite the large availability of waste heat, especially at low temperatures (<250 °C), the implementation rate of heat recovery interventions is still low, mainly due to non-technical barriers. To overcome this limitation, this work aims to develop two distinct databases containing waste heat recovery case studies and technologies as a novel tool to enhance knowledge transfer in the industrial sector. Through an in-depth analysis of the scientific literature, the two databases’ structures were developed, defining fields and information to collect, and then a preliminary population was performed. Both databases were validated by interacting with companies which operate in the heat recovery technology market and which are possible users of the tools. Those proposed are the first example in the literature of databases completely focused on low-temperature waste heat recovery in the industrial sector and able to provide detailed information on heat exchange and the technologies used. The tools proposed are two key elements in supporting companies in all the phases of a heat recovery intervention: from identifying waste heat to choosing the best technology to be adopted.


MRS Advances ◽  
2020 ◽  
Vol 5 (10) ◽  
pp. 481-487 ◽  
Author(s):  
Norifusa Satoh ◽  
Masaji Otsuka ◽  
Yasuaki Sakurai ◽  
Takeshi Asami ◽  
Yoshitsugu Goto ◽  
...  

ABSTRACTWe examined a working hypothesis of sticky thermoelectric (TE) materials, which is inversely designed to mass-produce flexible TE sheets with lamination or roll-to-roll processes without electric conductive adhesives. Herein, we prepared p-type and n-type sticky TE materials via mixing antimony and bismuth powders with low-volatilizable organic solvents to achieve a low thermal conductivity. Since the sticky TE materials are additionally injected into punched polymer sheets to contact with the upper and bottom electrodes in the fabrication process, the sticky TE modules of ca. 2.4 mm in thickness maintained temperature differences of ca. 10°C and 40°C on a hot plate of 40 °C and 120°C under a natural-air cooling condition with a fin. In the single-cell resistance analysis, we found that 75∼150-µm bismuth powder shows lower resistance than the smaller-sized one due to the fewer number of particle-particle interfaces in the electric pass between the upper and bottom electrodes. After adjusting the printed wiring pattern for the upper and bottom electrodes, we achieved 42 mV on a hot plate (120°C) with the 6 x 6 module having 212 Ω in the total resistance. In addition to the possibility of mass production at a reasonable cost, the sticky TE materials provide a low thermal conductivity for flexible TE modules to capture low-temperature waste heat under natural-air cooling conditions with fins for the purpose of energy harvesting.