Prevalence and prognostic value of perfusion defects detected by stress technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography in asymptomatic patients with diabetes mellitus and no known coronary artery disease

2002 ◽  
Vol 90 (8) ◽  
pp. 827-832 ◽  
Author(s):  
Andrea De Lorenzo ◽  
Ronaldo S.L Lima ◽  
Aristarco G Siqueira-Filho ◽  
Mauricio R Pantoja
2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Yukinori Shinoda ◽  
Koichi Tachibana ◽  
Tomoko Minamisaka ◽  
Hidetada Fukuoka ◽  
Hirooki Inui ◽  
...  

Abstract Background Myocardial perfusion single-photon emission computed tomography (SPECT) imaging with stress is a useful examination for detecting coronary artery disease. Since the presence of artifacts is remaining challenges, we aimed to define the minimum intensity of low-grade exercise stress levels combined with drug stress to reduce undesired artifacts and their related factors. Methods We divided patients with suspicious coronary artery disease into 4 groups as follows: group A, adenosine triphosphate (ATP) for 6 min; group A + 25 W, ATP + 25 W exercise for 6 min; group A + 35 W, ATP + 35 W exercise for 6 min; group A + 45 W, ATP + 45 W exercise for 6 min) and enrolled only those whose summed stress scores were < 3. Undesired artifacts were evaluated on the basis of heart-to-liver activity (H/L) ratio and heart-to-10 pixels below the heart (H/below the H) ratio. Results The logarithmic values of H/L and H/below the H ratios were significantly higher in groups A + 35 W and A + 45 W than in group A (p < 0.05, each). In all the patients, the logarithmic values of H/L and H/below the H ratios positively correlated with the increment of rate pressure product (RPP, p = 0.002 and p = 0.005, respectively) after stress in the univariate analysis. The left ventricular end-diastolic volume (LVEDV) after stress (p = 0.002) negatively correlated with the logarithmic value of H/below the H ratio, but not H/L ratio. Although the increment of RPP was independently associated with the logarithmic values of both H/L (p = 0.001) and H/below the H ratios (p = 0.005), LVEDV was also independently associated with the logarithmic value of H/below the H ratio (p < 0.001) in multivariate regression analysis under adjusting with age and sex. Conclusion ATP plus ≥35 W exercise stress for 6 min was useful for reducing undesired artifacts after stress in myocardial perfusion SPECT. LVEDV after stress in addition to the increment of RPP was independently associated with the H/below the H ratio, but not the H/L ratio.


Author(s):  
E. Gordon DePuey

Artifacts and normal variants are a significant source of false-positive interpretations of myocardial perfusion single-photon emission computed tomography (SPECT). This chapter discusses how, by anticipating and recognizing such findings, the astute technologist and interpreting physician can increase test specificity in the diagnosis of coronary artery disease and avoid unnecessary catheterization of normal patients.


Sign in / Sign up

Export Citation Format

Share Document