Heat loss reduction

1988 ◽  
Vol 156 (3) ◽  
pp. 28B
Keyword(s):  
2011 ◽  
Vol 197-198 ◽  
pp. 1708-1711
Author(s):  
Cheng Qian

Nowadays in the market, there are many kinds of warm retention materials. Although each material has its own heat loss reduction, there should be methods for evaluating the warmth properties and giving out reliable results. In this paper, the warmth retention properties of three typical non-woven wadding were studied. On the basis of four warming related tests and analyses, the conclusions were got that after filming, because of existence of motionless air, their warmth retention properties increase obviously. In the same time, the air permeability of the three non-woven wadding decrease clearly because of the film on the wadding surface which obstructs air from flowing easily.


1987 ◽  
Vol 27 (2) ◽  
pp. 127-131 ◽  
Author(s):  
G.N. Tiwari ◽  
Y.P. Yadav ◽  
A. Srivastava

2009 ◽  
Vol 32 (2) ◽  
pp. 3067-3073 ◽  
Author(s):  
Takashi Sakurai ◽  
Saburo Yuasa ◽  
Taku Honda ◽  
Shoko Shimotori

Energies ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6666
Author(s):  
Beata Sadowska ◽  
Piotr Bieranowski

Many buildings have considerable thermal bridges at the junction of balcony slabs with walls. To achieve the new EU directive targets related to energy efficiency, greater attention should be paid to such design details. This study analyzes the efficiency of traditional balcony slab modernization methods, the use of modern insulation materials and a new alternative system: an added self-supporting light balcony system (LKBD) in retrofitted large-panel buildings. The main objective was to capture cost-effective renovation methods from both the heat loss reduction perspectives and risk of surface condensation. The analyses, carried out in four buildings, have shown that at current costs, the thermal modernization of balconies is not economically efficient (SPBT>98.4 years). However, it is necessary because leaving the balcony slabs without insulation or only insulating them from the bottom carries the risk of surface condensation. The most cost-effective renovation method is to insulate the balcony slabs from below and above with the thickest possible XPS layer (SPBT = 98.4 years; 107.4 years). Replacing XPS with modern material increases SPBT by almost 50%, for the LKBD system, SPBT = 269.2–281.5 years. More favorable energy and economic effects related to the reduction of balcony thermal bridges were achieved in the wall with lower insulation.


2016 ◽  
Vol 5 (3) ◽  
pp. P172-P178 ◽  
Author(s):  
A. Ramos ◽  
J. Valdehita ◽  
J. C. Zamorano ◽  
C. del Cañizo

2012 ◽  
Vol 27 (1) ◽  
pp. 53-58 ◽  
Author(s):  
Otto Henriksson ◽  
Peter Lundgren ◽  
Kalev Kuklane ◽  
Ingvar Holmér ◽  
Peter Naredi ◽  
...  

AbstractIntroduction: In the prehospital care of a cold and wet person, early application of adequate insulation is of utmost importance to reduce cold stress, limit body core cooling, and prevent deterioration of the patient’s condition. Most prehospital guidelines on protection against cold recommend the removal of wet clothing prior to insulation, and some also recommend the use of a waterproof vapor barrier to reduce evaporative heat loss. However, there is little scientific evidence of the effectiveness of these measures.Objective: Using a thermal manikin with wet clothing, this study was conducted to determine the effect of wet clothing removal or the addition of a vapor barrier on thermal insulation and evaporative heat loss using different amounts of insulation in both warm and cold ambient conditions.Methods: A thermal manikin dressed in wet clothing was set up in accordance with the European Standard for assessing requirements of sleeping bags, modified for wet heat loss determination, and the climatic chamber was set to -15 degrees Celsius (°C) for cold conditions and +10°C for warm conditions. Three different insulation ensembles, one, two or seven woollen blankets, were chosen to provide different levels of insulation. Five different test conditions were evaluated for all three levels of insulation ensembles: (1) dry underwear; (2) dry underwear with a vapor barrier; (3) wet underwear; (4) wet underwear with a vapor barrier; and (5) no underwear. Dry and wet heat loss and thermal resistance were determined from continuous monitoring of ambient air temperature, manikin surface temperature, heat flux and evaporative mass loss rate.Results: Independent of insulation thickness or ambient temperature, the removal of wet clothing or the addition of a vapor barrier resulted in a reduction in total heat loss of 19-42%. The absolute heat loss reduction was greater, however, and thus clinically more important in cold environments when little insulation is available. A similar reduction in total heat loss was also achieved by increasing the insulation from one to two blankets or from two to seven blankets.Conclusion: Wet clothing removal or the addition of a vapor barrier effectively reduced evaporative heat loss and might thus be of great importance in prehospital rescue scenarios in cold environments with limited insulation available, such as in mass-casualty situations or during protracted evacuations in harsh conditions.


Author(s):  
Mohd Azfar Nazim ◽  
Sharmin Abdullah ◽  
Mirza Mohammad Maqbule Elahi
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document