scholarly journals Efficiency of Different Balcony Slab Modernization Method in Retrofitted Multi-Family Buildings

Energies ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6666
Author(s):  
Beata Sadowska ◽  
Piotr Bieranowski

Many buildings have considerable thermal bridges at the junction of balcony slabs with walls. To achieve the new EU directive targets related to energy efficiency, greater attention should be paid to such design details. This study analyzes the efficiency of traditional balcony slab modernization methods, the use of modern insulation materials and a new alternative system: an added self-supporting light balcony system (LKBD) in retrofitted large-panel buildings. The main objective was to capture cost-effective renovation methods from both the heat loss reduction perspectives and risk of surface condensation. The analyses, carried out in four buildings, have shown that at current costs, the thermal modernization of balconies is not economically efficient (SPBT>98.4 years). However, it is necessary because leaving the balcony slabs without insulation or only insulating them from the bottom carries the risk of surface condensation. The most cost-effective renovation method is to insulate the balcony slabs from below and above with the thickest possible XPS layer (SPBT = 98.4 years; 107.4 years). Replacing XPS with modern material increases SPBT by almost 50%, for the LKBD system, SPBT = 269.2–281.5 years. More favorable energy and economic effects related to the reduction of balcony thermal bridges were achieved in the wall with lower insulation.

2013 ◽  
Vol 787 ◽  
pp. 731-735 ◽  
Author(s):  
Jose Vercher ◽  
Carlos Lerma ◽  
Marisol Vidal ◽  
Enrique Gil

Façade-slab connection is the main thermal bridge of buildings. In this work, different options are analyzed according to the location of the thermal insulation. Heat loss is measured for each option. According to thermal analysis performed we conclude that cover the buildings façade completely without interruption at the slabs front is essential to avoid thermal bridges. The new option that interrupts the cantilever to put insulation on the entire façade is just effective to isolate the entire cantilever and is an easier constructive solution. This insulation continuity is needed to prevent ceiling condensation, since the energy saving is not important compared to windows thermal loss.


2018 ◽  
pp. 113-119
Author(s):  
Gennady Ya. Vagin ◽  
Eugene B. Solntsev ◽  
Oleg Yu. Malafeev

The article analyses critera applying to the choice of energy efficient high quality light sources and luminaires, which are used in Russian domestic and international practice. It is found that national standards GOST P 54993–2012 and GOST P 54992– 2012 contain outdated criteria for determining indices and classes of energy efficiency of light sources and luminaires. They are taken from the 1998 EU Directive #98/11/EU “Electric lamps”, in which LED light sources and discharge lamps of high intensity were not included. A new Regulation of the European Union #874/2012/EU on energy labelling of electric lamps and luminaires, in which these light sources are taken into consideration, contains a new technique of determining classes of energy efficiency and new, higher classes are added. The article has carried out a comparison of calculations of the energy efficiency classes in accordance with GOST P 54993 and with Regulation #874/2012/EU, and it is found out that a calculation using GOST P 54993 gives underrated energy efficiency classes. This can lead to interdiction of export for certain light sources and luminaires, can discredit Russian domestic manufacturer light sources and does not correspond to the rules of the World Trade Organization (WTO).


2011 ◽  
Vol 197-198 ◽  
pp. 1708-1711
Author(s):  
Cheng Qian

Nowadays in the market, there are many kinds of warm retention materials. Although each material has its own heat loss reduction, there should be methods for evaluating the warmth properties and giving out reliable results. In this paper, the warmth retention properties of three typical non-woven wadding were studied. On the basis of four warming related tests and analyses, the conclusions were got that after filming, because of existence of motionless air, their warmth retention properties increase obviously. In the same time, the air permeability of the three non-woven wadding decrease clearly because of the film on the wadding surface which obstructs air from flowing easily.


1987 ◽  
Vol 27 (2) ◽  
pp. 127-131 ◽  
Author(s):  
G.N. Tiwari ◽  
Y.P. Yadav ◽  
A. Srivastava

Forests ◽  
2018 ◽  
Vol 9 (8) ◽  
pp. 481 ◽  
Author(s):  
Kevin Nyongesa ◽  
Harald Vacik

This paper proposes an Integrated Fire Management (IFM) framework that can be used to support communities and resource managers in finding effective and efficient approaches to prevent damaging fires, as well as to maintain desirable fire regimes in Kenya. Designing and implementing an IFM approach in Kenya calls for a systematic understanding of the various uses of fire and the underlying perceptions and traditional ecological knowledge of the local people. The proposed IFM framework allows different stakeholders to evaluate the risks posed by fires and balance them with their beneficial ecological and economic effects making it easier for them to develop effective fire management approaches. A case study of the proposed IFM framework was conducted in Gathiuru Forest, which that is part of the larger Mt. Kenya Forest Ecosystem. Focus group discussions were held with key resource persons, primary and secondary data on socio-economic activities was studied, fire and weather records were analysed and the current fire management plans were consulted. Questionnaires were used to assess how the IFM is implemented in the Gathiuru Forest Station. The results show that the proposed IFM framework is scalable and can be applied in places with fire-dependent ecosystems as well as in places with fire-sensitive ecosystems in Kenya. The effectiveness of the proposed IFM framework depends on the active participation, formulation and implementation of the IFM activities by the main stakeholder groups (Kenya Forest Service (KFS), Kenya Wildlife Service (KWS), and the Community Forest Associations (CFA). The proposed IFM framework helps in implementing cost-effective approaches to prevent damaging fires and maintain desirable fire regimes in Kenya.


2020 ◽  
Vol 02 (12) ◽  
pp. 86-89
Author(s):  
Axmedov Tolkin ◽  

This article provides basic information on engineering selection and beautification of urban areas where 5-storey residential buildings should be built in response to emergencies in ways to increase the energy efficiency of buildings using atmospheric water for technical purposes.


2019 ◽  
Vol 10 (2) ◽  
pp. 59-66
Author(s):  
E. A Biryuzova ◽  
A. S Glukhanov

Through pipelines of heat networks, due to their large length, a large amount of thermal energy is lost. Identification of technical solutions related to improving the energy efficiency of heating networks is an urgent task at present. The article is devoted to the consideration of options for laying pipelines of heat networks during design work. In the conducted studies, two main methods of underground laying of pipelines of heat networks with the choice of the most energy-efficient, with minimal losses of thermal energy are considered. Channel and channelless laying methods are investigated with the same design features and technological conditions of operation of pipelines of heat networks using the same thermal insulation material. For each option, the required thickness of the thermal insulation is determined by the normalized density of the heat flow, thermal calculations are performed to determine the heat loss and the value of the temperature fields generated around the operating pipelines of the heat networks. The obtained values of the thermal insulation thickness in the channel method of laying pipelines are 30-50 % lower than those in channelless laying. The heat loss values, according to the results of the heat calculation for the options under consideration, in the channel method of laying are reduced by 47-65 %. The temperature fields formed around the pipelines of thermal networks with channelless laying significantly exceed the natural value of the soil temperature at the depth of the pipeline. What has a great influence on the determination of the distance to adjacent pipelines and other utilities, laid underground, in the zone of the thermal network. A comparative analysis of the results obtained makes it possible to single out the choice of the method of laying the pipeline into a group of measures aimed at energy saving and increasing energy efficiency in heating systems.


Author(s):  
Hemavathi P ◽  
Nandakumar A. N.

Clustering is one of the operations in the wireless sensor network that offers both streamlined data routing services as well as energy efficiency. In this viewpoint, Particle Swarm Optimization (PSO) has already proved its effectiveness in enhancing clustering operation, energy efficiency, etc. However, PSO also suffers from a higher degree of iteration and computational complexity when it comes to solving complex problems, e.g., allocating transmittance energy to the cluster head in a dynamic network. Therefore, we present a novel, simple, and yet a cost-effective method that performs enhancement of the conventional PSO approach for minimizing the iterative steps and maximizing the probability of selecting a better clustered. A significant research contribution of the proposed system is its assurance towards minimizing the transmittance energy as well as receiving energy of a cluster head. The study outcome proved proposed a system to be better than conventional system in the form of energy efficiency.


Sign in / Sign up

Export Citation Format

Share Document