Medical and Dental Guidance Notes. A Good Practice Guide on All Aspects of Ionising Radiation Protection in the Clinical Environment

2003 ◽  
Vol 58 (4) ◽  
pp. 338
Author(s):  
L Harris ◽  
C Evans
2021 ◽  
Author(s):  
Brenda Barrios Becerra ◽  
Sodel Vazquez Reyes ◽  
Alejandra Garcia Hernandez ◽  
Perla Velasco Elizondo ◽  
Alejandro Mauricio Gonzalez

Metrology ◽  
2022 ◽  
Vol 2 (1) ◽  
pp. 19-32
Author(s):  
Janik Schaude ◽  
Andreas Christian Gröschl ◽  
Tino Hausotte

The article presents the determination of the topographic spatial resolution of an optical point sensor. It is quantified by the lateral period limit DLIM measured on a type ASG material measure, also called (topographic) Siemens star, with a confocal sensor following both a radial measurement and evaluation, as proposed by ISO 25178-70, and the measurement and subsequent evaluation of two line scans, proposed by the NPL Good Practice Guide. As will be shown, for the latter, an only slightly misidentified target centre of the Siemens star leads to quite significant errors of the determined DLIM. Remarkably, a misidentified target centre does not necessarily result in an overestimation of DLIM, but lower values might also be obtained. Therefore, a modified Good Practice Guide is proposed to determine DLIM more accurately, as it includes a thorough determination of the centre of the Siemens star as well. While the measurement and evaluation effort is increased slightly compared to the NPL Good Practice Guide, it is still much faster than a complete radial measurement and evaluation.


2021 ◽  
Vol 2 (1) ◽  
pp. 13-22
Author(s):  
JE Ikubor ◽  
SN Awunor ◽  
EE Atare

It is important that doctors of the various specialties in a health facility requesting for radiological examinations are knowledgeable about the effect of ionizing radiation. When referring doctors know the amount of radiation their patients receive there will be justification for such investigations in line with the guiding principle of radiation protection – As Low As Reasonably Achievable (ALARA) - to minimize risk to the patient. The objective of this study is to assess the knowledge and practice of radiation protection and safety amongst doctors in a Teaching Hospital in the Niger Delta, Nigeria. This is a cross-sectional descriptive study using a self-administered structured questionnaire among 131 doctors in Delta State University Teaching Hospital (DELSUTH), Oghara. Data was analyzed using the IBM SPSS v.21. Eighty-eight (67.2%) respondents had a good knowledge of radiation safety while 49 (37.4%) of respondents had a good practice of radiation protection and safety. There was an association between the department of respondents (p=0.009), awareness of body parts sensitive to radiation (p=0.005) and their knowledge of radiation safety. Also, there was an association between the department of respondents (p=0.016), their years of experience (p=0.016) and the practice of radiation safety. Knowledge of radiation safety was high while the practice of radiation protection and safety was low amongst respondents. Gender, department of doctor and awareness of body parts that are sensitive to radiation were associated with good knowledge; while department and years of experience was associated with good practice. It is recommended that doctors receive regular updates on radiation hazards, risks and protection in order to reduce the risk of exposure of patients and health workers to unnecessary ionizing radiation.


2021 ◽  
Author(s):  
Peter Farrall ◽  
Stephen Brookhouse
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document