Diagnostic accuracy of magnetic resonance cholangiopancreatography for biliary disease

2000 ◽  
Vol 118 (4) ◽  
pp. A452
Author(s):  
Yoshinori Kitazumi ◽  
Satoshi Kanozawa ◽  
Toshiki Anzai ◽  
Mamoru Iimuro ◽  
Morio Takahashi ◽  
...  
Author(s):  
M. Vignesh Kumar

This is a prospective study done to compare the diagnostic accuracy of Magnetic Resonance Cholangiopancreatography (MRCP) in patients undergoing Endoscopic Retrograde Cholangiopancreatography (ERCP) for pancreaticobiliary disorders.Majority of the study participants were males (63.3%), while the rest 36.78% of them were females and periampullary carcinoma (11.7%) and common bile duct calculus (11.7%) are the common cause of obstruction found on MRCP followed by malignant stricture (10%). The extent of obstruction was determined in most of the study participants (91.7%) by MRCP while the rest 8.3% were not determined by MRCP. The Common bile duct calculus (11.7%) is the common cause of obstruction on ERCP followed by malignant stricture (10%) and Periampullary carcinoma (10%) and 20% of the patients were found to be normal in ERCP. Among them, 71.4 % did not show MRCP and the association was found to be significant. (p- Value < 0.00).


2021 ◽  
Vol 15 (12) ◽  
pp. 3421-3423
Author(s):  
Kamran Naseem ◽  
Malik Mudasir Hassan ◽  
Sarah Nisar

Objectives: To find out the diagnostic accuracy of magnetic resonance cholangiopancreatography in benign and malignant lesions in patients of obstructive jaundice, taking histopathology as gold standard. Material and methods: This cross sectional study was conducted at Department of Radiology, Bahawal Victoria Hospital, Bahawalpur October 2019 to April 2020. A total of 164 patients with suspected cases of obstructive jaundice and age 25-65 years of either gender were included. Then magnetic resonance cholangiopancreatography (MRCP) was performed in every patient by 1.5 Tesla MR System using a torso phased-array coil. After this, each patient was undergone operation in the concerned ward. Findings of MRCP were compared with the findings of histopathology. Results: In MRCP positive patients, 78 were true positive (TP) and 13 were false positive (FP). Among 73, MRCP negative patients, 08 were false negative (FN) whereas 65 were True Negative (TN). Overall specificity, sensitivity, NPV, PPV and diagnostic accuracy of magnetic resonance cholangiopancreatography in benign and malignant lesions in patients of obstructive jaundice, taking histopathology as gold standard was 90.70%, 83.33%, 85.71%, 89.04% and 87.20% respectively. Conclusion: This study concluded that magnetic resonance cholangiopancreatography (MRCP) is the non-invasive modality of choice with diagnostic accuracy in diagnosing in benign and malignant lesions in obstructive jaundice patients. Keywords: obstructive jaundice, sensitivity, magnetic resonance imaging.


Sign in / Sign up

Export Citation Format

Share Document