Su1855 The Frequency-Velocity Correlation of Porcine Gastric Slow Waves Defined Through High-Resolution Entrainment Mapping

2015 ◽  
Vol 148 (4) ◽  
pp. S-534-S-535
Author(s):  
Peng Du ◽  
Niranchan Paskaranandavadivel ◽  
Timothy R. Angeli ◽  
Leo K. Cheng ◽  
Gregory O'Grady
2021 ◽  
Author(s):  
Stefan Calder ◽  
Leo K Cheng ◽  
Christopher Andrews ◽  
Niranchan Paskaranandavadivel ◽  
Stephen Waite ◽  
...  

Gastric disorders are increasingly prevalent, but reliable clinical tools to objectively assess gastric function are lacking. Body-surface gastric mapping (BSGM) is a non-invasive method for the detection of gastric electrophysiological biomarkers including slow wave direction, which have correlated with symptoms in patients with gastroparesis and functional dyspepsia. However, no studies have validated the relationship between gastric slow waves and body surface activation profiles. This study aimed to comprehensively evaluate the relationship between gastric slow waves and body-surface recordings. High-resolution electrode arrays were placed to simultaneously capture slow waves from the gastric serosa (32 x 6 electrodes at 4 mm resolution) and abdominal surface (8x8 at 20 mm inter-electrode spacing) in a porcine model. BSGM signals were extracted based on a combination of wavelet and phase information analyses. A total of 1185 individual cycles of slow waves assessed, out of which 897 (76%) were normal antegrade waves, occurring in 10/14 (71%) subjects studied. BSGM accurately detected the underlying slow wave in terms of frequency (r = 0.99, p = 0.43) as well as the direction of propagation (p = 0.41, F-measure: 0.92). In addition, the cycle-by-cycle match between BSGM and transitions of gastric slow waves in terms either or both temporal and spatial abnormalities was demonstrated. These results validate BSGM as a suitable method for non-invasively and accurately detecting gastric slow wave activation profiles from the body surface.


2001 ◽  
Vol 280 (6) ◽  
pp. G1370-G1375 ◽  
Author(s):  
Xuemei Lin ◽  
Jiande Z. Chen

The aim of this study was to utilize multichannel electrogastrography to investigate whether patients with functional dyspepsia had impaired propagation or coordination of gastric slow waves in the fasting state compared with healthy controls. The study was performed in 10 patients with functional dyspepsia and 11 healthy subjects. Gastric myoelectrical activity was measured by using surface electrogastrography with a specially designed four-channel device. The study was performed for 30 min or more in the fasting state. Special computer programs were developed for the computation of the propagation and coupling of the gastric slow wave. It was found that, compared with the healthy controls, the patients showed a significantly lower percentage of slow wave propagation (58.0 ± 8.9 vs. 89.9 ± 2.6%, P < 0.002) and a significantly lower percentage of slow wave coupling (46.9 ± 4.4 vs. 61.5 ± 6.9%, P < 0.04). In addition, the patients showed inconsistencies in the frequency and regularity of the gastric slow wave among the four-channel electrogastrograms (EGGs). It was concluded that patients with functional dyspepsia have impaired slow wave propagation and coupling. Multichannel EGG has more information than single-channel EGG for the detection of gastric myoelectrical abnormalities.


Sign in / Sign up

Export Citation Format

Share Document