SINGLE CENTRE LONG TERM RESULTS OF INTERNAL URETHROTOMY IN 924 MALE PATIENTS

2008 ◽  
Vol 179 (4S) ◽  
pp. 179-179
Author(s):  
Florian Imkamp ◽  
Thomas R Herrmann ◽  
Udo Jonas ◽  
Martin Buchardt
2021 ◽  
Vol 11 (5) ◽  
pp. 344
Author(s):  
Ching-Feng Wu ◽  
Jui-Ying Fu ◽  
Chi-Tsung Wen ◽  
Chien-Hung Chiu ◽  
Ming-Ju Hsieh ◽  
...  

Intravenous ports serve as vascular access and are indispensable in cancer treatment. Most studies are not based on a systematic and standardized approach. Hence, the aim of this study was to demonstrate long-term results of port implantation following a standard algorithm. A total of 2950 patients who underwent intravenous port implantation between March 2012 and December 2018 were included. Data of patients managed following a standard algorithm were analyzed for safety and long-term outcomes. The cephalic vein was the predominant choice of entry vessel. In female patients, wire assistance without use of puncture sheath was less likely and echo-guided puncture via internal jugular vein (IJV) with use of puncture sheath was more likely to be performed, compared to male patients (p < 0.0001). The procedure-related complication rate was 0.07%, and no pneumothorax, hematoma, catheter kinking, catheter fracture, or pocket erosion was reported. Catheter implantations by echo-guided puncture via IJV notably declined from 4.67% to 0.99% (p = 0.027). Mean operative time gradually declined from 37.88 min in 2012 to 23.20 min in 2018. The proposed standard algorithm for port implantation reduced the need for IJV echo-guided approach and eliminated procedure-related catastrophic complications. In addition, it shortened operative time and demonstrated good functional results.


2017 ◽  
Vol 120 (2) ◽  
pp. 273-279 ◽  
Author(s):  
Arkadius Kocot ◽  
Charis Kalogirou ◽  
Daniel Vergho ◽  
Hubertus Riedmiller

2016 ◽  
Vol 22 (6) ◽  
pp. 654-658 ◽  
Author(s):  
Christopher J Stapleton ◽  
Collin M Torok ◽  
Aman B Patel

Background Penumbra SMART coils differ from traditional microcoils used for endovascular coil embolization of intracranial aneurysms (IAs) in that they (1) become progressively softer from their distal to proximal end, rather than being of uniform stiffness, (2) have a tight conformational structure, and (3) have a more robust stretch-resistance platform. These properties aid in preventing microcatheter prolapse and coil herniation during coil deployment and in filling small pockets of the aneurysm sac. Objective/Methods To determine the safety and efficacy of this device, the records of 17 consecutive patients with IAs treated with SMART coils were retrospectively analyzed. Results Thirteen female and four male patients were identified. Eleven patients presented with subarachnoid hemorrhage, four had recurrent aneurysms, and two had incidentally discovered aneurysms. Twelve aneurysms (two of which were recurrent) were treated with stand-alone coiling, three were treated with stent-assisted coiling, and two with flow diversion with adjuvant coiling. Microcatheter prolapse occurred in one case of a recurrent aneurysm, due to mechanical limitations imposed by a stent placed during prior coiling. Raymond-Roy Occlusion Classification (RROC) I or II occlusion was achieved in 12 aneurysms, including all 10 undergoing primary stand-alone coiling. Of the five RROC III occlusions, two were expected given treatment with flow diversion, while the other three occurred in complex, recurrent aneurysms. One patient suffered a thromboembolic complication of unclear clinical significance. Conclusions The Penumbra SMART coil is a safe and effective device for the endovascular treatment of IAs. Follow-up studies are required to establish long-term results.


2017 ◽  
Vol 27 (7) ◽  
pp. 1314-1322
Author(s):  
Petra Loureiro ◽  
Barbara Cardoso ◽  
Inês B. Gomes ◽  
José F. Martins ◽  
Fátima F. Pinto

AbstractIntroductionPercutaneous balloon valvuloplasty is the primary treatment for critical pulmonary valve stenosis in neonates. Thus far, a few studies have reported long-term results of this technique in neonatal critical pulmonary valve stenosis.MethodsWe carried out a retrospective study of all consecutive newborns with critical pulmonary valve stenosis subjected to percutaneous balloon valvuloplasty at a single centre, between 1994 and 2014, to assess its immediate and long-term safety and efficacy.ResultsA total of 24 neonates presented with critical pulmonary valve stenosis. The mean diameter of the pulmonary annulus was 7 mm (±1.19); 33.3% had a dysplastic pulmonary valve, and 92% were started on prostaglandin E1 treatment. Percutaneous balloon valvuloplasty was performed at a mean age of 4.0±4.3 days using, on average, a balloon-to-pulmonary annulus ratio of 1.18 mm (with a range from 0.9 to 1.43). Immediate success was achieved in 22/24 patients (92%) with a reduction in the pulmonary transvalvular peak gradient (p<0.05) and in the right ventricle/systemic pressure ratio (p<0.05). There was one death (4%) 6 days after the procedure, and 29.2% of them had transient rhythm complications. For a mean follow-up time of 8.4 years, the re-intervention rate was 42.9%. In total, 14 re-interventions were performed in nine neonates, including surgery in six. Freedom from re-intervention was 50% at 8 years and 43% at 10 and 15 years.ConclusionThis series, to the best of our knowledge, has had the longest follow-up of neonates with critical pulmonary valve stenosis. Percutaneous balloon valvuloplasty is a safe and effective treatment, and in our study 75% of the patients were exclusively treated using this technique.


2014 ◽  
Vol 19 (6) ◽  
pp. 978-984 ◽  
Author(s):  
Antonio Lio ◽  
Michele Murzi ◽  
Gioia Di Stefano ◽  
Antonio Miceli ◽  
Enkel Kallushi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document