Solid phase extraction and determination of ultra trace amounts of copper(II) using octadecyl silica membrane disks modified by 11-hydroxynaphthacene-5,12-quinone and flame atomic absorption spectrometry

Talanta ◽  
2001 ◽  
Vol 54 (5) ◽  
pp. 863-869 ◽  
Author(s):  
M Shamsipur
2011 ◽  
Vol 2011 ◽  
pp. 1-6 ◽  
Author(s):  
Vanessa N. Alves ◽  
Simone S. O. Borges ◽  
Waldomiro B. Neto ◽  
Nívia M. M. Coelho

In this study, a method for the determination of low concentrations of lead in beer samples using solid-phase extraction with a flow injection analysis system and detection by flame atomic absorption spectrometry (FAAS) was developed.Moringa oleiferaseeds were used as a biosorbent material. Chemical and flow variables of the online preconcentration system, such as sample pH, preconcentration flow rate, eluent flow rate, eluent concentration, particle size, and sorbent mass, were studied. The optimum extraction conditions were obtained using a sample pH of 6.0, sample flow rate of 6.0 mL min−1, 63.0 mg of sorbent mass, and 2.0 mol L−1HNO3at a flow rate of 2.0 mL min−1as the eluent. With the optimized conditions, the preconcentration factor, precision, detection limit, consumption index, and sample throughput were estimated as 93, 0.3% (10.0 μg L−1,n=7), 7.5 μg L−1, 0.11 mL, and 23 samples per hour, respectively. The method developed was successfully applied to beer samples and recovery tests, with recovery ranging from 80% to 100%.