The optimum performance of a solar-assisted combined absorption-vapor compression system for air conditioning and space heating

2002 ◽  
Vol 43 (4) ◽  
pp. 285
Author(s):  
S. Güktun ◽  
E.R. Deha
2021 ◽  
Vol 2042 (1) ◽  
pp. 012182
Author(s):  
B Marshall ◽  
J Felkner ◽  
Z Nagy

Abstract This research project compared a standard vapor compression system and a standard desiccant dehumidification system with heat wheel to determine if there was some potential energy savings for “shoulder season” hours in Austin Texas. “Shoulder season” hours as defined in the paper are hours during which the dry bulb temperature falls within the American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE) comfort bound but the humidity is above the comfortable humidity point. These hours are normally addressed with vapor compression systems which dehumidify by cooling the air under the comfort setpoint to dehumidify, which is wasteful of energy. The study found that for these shoulder season hours a desiccant dehumidification system was around 4.5 times more energy efficient at reaching comfort setpoints if free heating was used for drying the desiccant.


Author(s):  
Vikas Kumar ◽  
Gulshan Sachdeva ◽  
Sandeep Tiwari ◽  
Parinam Anuradha ◽  
Vaibhav Jain

A conventional vapor compression refrigeration system (VCRS) cascaded with a heat-assisted ejector refrigeration system (ERS) has been experimentally analyzed. Cascading allows the VCRS to operate at lower condenser temperatures and thus achieve a higher coefficient of performance. In this cascaded system, the condenser of the vapor compression system does not dissipate its heat directly to the evaporator of the ERS; instead, water circulates between the condenser of VCRS and the evaporator of ERS to exchange the heat. Seven ejectors of different geometries have been used in the ERS; however, all the ejectors could not maintain thermal equilibrium at the desired operating conditions. The compressor of the cascaded VCRS consumed 1.3 times less power than the noncascaded VCRS. Furthermore, the cascaded system provided a maximum 87.74% improvement in COP over the noncascaded system for the same operating conditions. The performance of the system remained constant until the critical condenser pressure of the ERS.


2021 ◽  
Vol 122 ◽  
pp. 97-109
Author(s):  
Yudong Xia ◽  
Qiang Ding ◽  
Nijie Jing ◽  
Aipeng Jiang ◽  
Xuejun Zhang ◽  
...  

2019 ◽  
Vol 27 (03) ◽  
pp. 1950029
Author(s):  
Vikas Kumar ◽  
Gulshan Sachdeva

The performance of an ejector as an expansion device rather than the conventional expansion valve or capillary tube in a vapor compression system is experimentally analyzed. Experiments have been conducted using 28 ejectors of different dimensions at the same condenser and evaporator temperatures, and it has been observed that for utmost performance, an optimum area ratio of the ejector is required. One of the ejector geometry has been experimented further for a wide range of condenser and evaporator temperatures. The coefficient of performance is found to be enhanced by at least 10% in comparison to the conventional vapor compression system for the considered range of condenser and evaporator temperatures and the maximum improvement in COP obtained is 12.83% at 14.3∘C evaporator temperature and 32.4∘C condenser temperature with 17.9211 ejector area ratio. The refrigerant R134a has been used as the working substance.


2011 ◽  
Vol 110-116 ◽  
pp. 2163-2169
Author(s):  
S. Khosravi ◽  
Yat Huang Yau ◽  
T.M.I. Mahlia ◽  
M.H. Saidi

In the recent researches HVAC with a based desiccant dehumidifier with a low ambient impact is more efficient in comparison to the traditional systems. Hybrid desiccant cooling systems can be used to control indoor air quality in buildings. This paper presents an integrated energy, entropy and exergy analysis of a hybrid desiccant cooling system compare to a compression system based on first and second laws of thermodynamic. The main objective is the use of a method called exergy costing applied to a conventional compression system that has been chosen to provide the proper conditioned air for a building in hot and humid condition. By applying the same method for the equivalent hybrid cooling system and finding the same exergy costing parameters, two systems can be in comparison to find the more economical system. The result illustrated hybrid desiccant cooling system can be providing 19.78% energy saving and 14.5% cheaper than the compression system the same capacity and lifetime. Nomenclature: