06/02274 Performance analysis of an irreversible Brayton heat engine based on ecological coefficient of performance criterion

2006 ◽  
Vol 47 (5) ◽  
pp. 347
2006 ◽  
Vol 83 (6) ◽  
pp. 558-572 ◽  
Author(s):  
Yasin Ust ◽  
Bahri Sahin ◽  
Ali Kodal ◽  
Ismail Hakki Akcay

Author(s):  
Srinivas Vanapalli ◽  
M. E. H. Tijani ◽  
Simon Spoelstra

Domestic heating contributes to a significant amount of energy usage in the Netherlands. Due to scare energy resources, attention to develop new and efficient technologies is increasing. At ECN, a burner driven heat pump employing thermoacoustic technology is being developed for possible applications in households and offices. The desired temperature lift is from 10 °C to 80 °C. As a first step the heat pump is driven by a linear motor. Measurements and performance analysis of the heat pump are presented in this paper. The heat pump has a coefficient of performance which is the ratio of heat produced to the work input of 1.38 when operating between 10 °C to 80 °C. The performance relative to maximum possible Carnot value is 26.5%.


2018 ◽  
Vol 140 (9) ◽  
Author(s):  
Baris Yilmaz ◽  
Ebru Mancuhan ◽  
Nasuh Erdonmez

Adverse effects of synthetic refrigerants on the environment have led to replacing them with natural refrigerants. The common candidates are ammonia, carbon dioxide, and several hydrocarbon compounds and their mixtures. Ammonia has been used mainly in large-scale cooling purposes such as large-scale supermarkets and climatic rooms. However, in such systems, leakage of ammonia may arise severe results on human health and may damage products in the cooled space. Recently, in last decade, a well-known refrigerant, CO2, has gained more attention to be applied in refrigeration systems due to having prominent thermo-physical properties. The performance analysis of a CO2/NH3 cascade (CAS) system has been theoretically examined in the current study. The detailed performance analysis of the system and optimization of the operating parameters have been studied extensively. In addition, the second-law analysis of the system with both cycles has been performed. Optimum operating conditions of the system are also determined and correlations are developed. Finally, the coefficient of performance (COP) correlations developed by several researchers in literature and those of current study are compared against available experimental COP results. The comparisons showed that the proposed correlations can be utilized for the accurate prediction of the COP of a cascade CO2/NH3 system within the studied range of operating conditions.


Sign in / Sign up

Export Citation Format

Share Document