F014 The use of fundamental frequency information for speech recognition via binaural-bimodal stimulation: cochlear implant on one ear and hearing aid on the other

Author(s):  
T. Shpak ◽  
T. Most ◽  
M. Luntz
2019 ◽  
Vol 40 (3) ◽  
pp. 621-635 ◽  
Author(s):  
Arlene C. Neuman ◽  
Annette Zeman ◽  
Jonathan Neukam ◽  
Binhuan Wang ◽  
Mario A. Svirsky

2018 ◽  
Vol 49 (6) ◽  
pp. 388-397
Author(s):  
François Prévost ◽  
Alexandre Lehmann

Cochlear implants restore hearing in deaf individuals, but speech perception remains challenging. Poor discrimination of spectral components is thought to account for limitations of speech recognition in cochlear implant users. We investigated how combined variations of spectral components along two orthogonal dimensions can maximize neural discrimination between two vowels, as measured by mismatch negativity. Adult cochlear implant users and matched normal-hearing listeners underwent electroencephalographic event-related potentials recordings in an optimum-1 oddball paradigm. A standard /a/ vowel was delivered in an acoustic free field along with stimuli having a deviant fundamental frequency (+3 and +6 semitones), a deviant first formant making it a /i/ vowel or combined deviant fundamental frequency and first formant (+3 and +6 semitones /i/ vowels). Speech recognition was assessed with a word repetition task. An analysis of variance between both amplitude and latency of mismatch negativity elicited by each deviant vowel was performed. The strength of correlations between these parameters of mismatch negativity and speech recognition as well as participants’ age was assessed. Amplitude of mismatch negativity was weaker in cochlear implant users but was maximized by variations of vowels’ first formant. Latency of mismatch negativity was later in cochlear implant users and was particularly extended by variations of the fundamental frequency. Speech recognition correlated with parameters of mismatch negativity elicited by the specific variation of the first formant. This nonlinear effect of acoustic parameters on neural discrimination of vowels has implications for implant processor programming and aural rehabilitation.


Author(s):  
Snandan Sharma ◽  
Waldo Nogueira ◽  
A. John van Opstal ◽  
Josef Chalupper ◽  
Lucas H. M. Mens ◽  
...  

Purpose Speech understanding in noise and horizontal sound localization is poor in most cochlear implant (CI) users with a hearing aid (bimodal stimulation). This study investigated the effect of static and less-extreme adaptive frequency compression in hearing aids on spatial hearing. By means of frequency compression, we aimed to restore high-frequency audibility, and thus improve sound localization and spatial speech recognition. Method Sound-detection thresholds, sound localization, and spatial speech recognition were measured in eight bimodal CI users, with and without frequency compression. We tested two compression algorithms: a static algorithm, which compressed frequencies beyond the compression knee point (160 or 480 Hz), and an adaptive algorithm, which aimed to compress only consonants leaving vowels unaffected (adaptive knee-point frequencies from 736 to 2946 Hz). Results Compression yielded a strong audibility benefit (high-frequency thresholds improved by 40 and 24 dB for static and adaptive compression, respectively), no meaningful improvement in localization performance (errors remained > 30 deg), and spatial speech recognition across all participants. Localization biases without compression (toward the hearing-aid and implant side for low- and high-frequency sounds, respectively) disappeared or reversed with compression. The audibility benefits provided to each bimodal user partially explained any individual improvements in localization performance; shifts in bias; and, for six out of eight participants, benefits in spatial speech recognition. Conclusions We speculate that limiting factors such as a persistent hearing asymmetry and mismatch in spectral overlap prevent compression in bimodal users from improving sound localization. Therefore, the benefit in spatial release from masking by compression is likely due to a shift of attention to the ear with the better signal-to-noise ratio facilitated by compression, rather than an improved spatial selectivity. Supplemental Material https://doi.org/10.23641/asha.16869485


2009 ◽  
Vol 20 (06) ◽  
pp. 353-373 ◽  
Author(s):  
Lisa G. Potts ◽  
Margaret W. Skinner ◽  
Ruth A. Litovsky ◽  
Michael J. Strube ◽  
Francis Kuk

Background: The use of bilateral amplification is now common clinical practice for hearing aid users but not for cochlear implant recipients. In the past, most cochlear implant recipients were implanted in one ear and wore only a monaural cochlear implant processor. There has been recent interest in benefits arising from bilateral stimulation that may be present for cochlear implant recipients. One option for bilateral stimulation is the use of a cochlear implant in one ear and a hearing aid in the opposite nonimplanted ear (bimodal hearing). Purpose: This study evaluated the effect of wearing a cochlear implant in one ear and a digital hearing aid in the opposite ear on speech recognition and localization. Research Design: A repeated-measures correlational study was completed. Study Sample: Nineteen adult Cochlear Nucleus 24 implant recipients participated in the study. Intervention: The participants were fit with a Widex Senso Vita 38 hearing aid to achieve maximum audibility and comfort within their dynamic range. Data Collection and Analysis: Soundfield thresholds, loudness growth, speech recognition, localization, and subjective questionnaires were obtained six–eight weeks after the hearing aid fitting. Testing was completed in three conditions: hearing aid only, cochlear implant only, and cochlear implant and hearing aid (bimodal). All tests were repeated four weeks after the first test session. Repeated-measures analysis of variance was used to analyze the data. Significant effects were further examined using pairwise comparison of means or in the case of continuous moderators, regression analyses. The speech-recognition and localization tasks were unique, in that a speech stimulus presented from a variety of roaming azimuths (140 degree loudspeaker array) was used. Results: Performance in the bimodal condition was significantly better for speech recognition and localization compared to the cochlear implant–only and hearing aid–only conditions. Performance was also different between these conditions when the location (i.e., side of the loudspeaker array that presented the word) was analyzed. In the bimodal condition, the speech-recognition and localization tasks were equal regardless of which side of the loudspeaker array presented the word, while performance was significantly poorer for the monaural conditions (hearing aid only and cochlear implant only) when the words were presented on the side with no stimulation. Binaural loudness summation of 1–3 dB was seen in soundfield thresholds and loudness growth in the bimodal condition. Measures of the audibility of sound with the hearing aid, including unaided thresholds, soundfield thresholds, and the Speech Intelligibility Index, were significant moderators of speech recognition and localization. Based on the questionnaire responses, participants showed a strong preference for bimodal stimulation. Conclusions: These findings suggest that a well-fit digital hearing aid worn in conjunction with a cochlear implant is beneficial to speech recognition and localization. The dynamic test procedures used in this study illustrate the importance of bilateral hearing for locating, identifying, and switching attention between multiple speakers. It is recommended that unilateral cochlear implant recipients, with measurable unaided hearing thresholds, be fit with a hearing aid.


2014 ◽  
Vol 23 (1) ◽  
pp. 79-92 ◽  
Author(s):  
Lisa G. Potts ◽  
Ruth Y. Litovsky

Purpose The use of bilateral stimulation is becoming common for cochlear implant (CI) recipients with either (a) a CI in one ear and a hearing aid (HA) in the nonimplanted ear (CI&HA—bimodal) or (b) CIs in both ears (CI&CI—bilateral). The objective of this study was to evaluate 4 individuals who transitioned from bimodal to bilateral stimulation. Method Participants had completed a larger study of bimodal hearing and subsequently received a second CI. Test procedures from the bimodal study, including roaming speech recognition, localization, and a questionnaire (the Speech, Spatial, and Qualities of Hearing Scale; Gatehouse & Noble, 2004) were repeated after 6–7 months of bilateral CI experience. Results Speech recognition and localization were not significantly different between bimodal and unilateral CI. In contrast, performance was significantly better with CI&CI compared with unilateral CI. Speech recognition with CI&CI was significantly better than with CI&HA for 2 of 4 participants. Localization was significantly better for all participants with CI&CI compared with CI&HA. CI&CI performance was rated as significantly better on the Speech, Spatial, and Qualities of Hearing Scale compared with CI&HA. Conclusions There was a strong preference for CI&CI for all participants. The variability in speech recognition and localization, however, suggests that performance under these stimulus conditions is individualized. Differences in hearing and/or HA history may explain performance differences.


2016 ◽  
Vol 12 (1) ◽  
pp. 16-22 ◽  
Author(s):  
Ignacio Sanhueza ◽  
Raquel Manrique ◽  
Alicia Huarte ◽  
Iñigo de Erenchun ◽  
Manuel Manrique

Sign in / Sign up

Export Citation Format

Share Document