scholarly journals TRANSCATHETER LEAK OCCLUSION WITH ENDOVASCULAR COILS FOLLOWING LEFT ATRIAL APPENDAGE CLOSURE

2020 ◽  
Vol 75 (11) ◽  
pp. 1134
Author(s):  
Domenico Giovanni Della Rocca ◽  
Rodney Horton ◽  
Sanghamitra Mohanty ◽  
Luigi Di Biase ◽  
Nicola Tarantino ◽  
...  
Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Domenico G Della Rocca ◽  
Rodney Horton ◽  
Luigi Di Biase ◽  
Nicola Tarantino ◽  
Jorge Romero ◽  
...  

Introduction: The Transcatheter Leak Closure With Detachable Coils Following Incomplete Left Atrial Appendage Closure Procedures (TREASURE) is a prospective, nonrandomized, single-center study. This study was undertaken to investigate the efficacy of transcatheter leak closure with endovascular coils in patient with incomplete percutaneous/epicardial left atrial appendage (LAA) closure procedures and high thromboembolic (TE)- and bleeding-risk. Hypothesis: We report the efficacy of transcatheter leak closure with endovascular coils in patients with incomplete LAA closure. Methods: Sixty-five consecutive patients with a clinically relevant residual leak (mean age: 72±8 years; 73.8% males; CHA 2 DS 2 -VASc: 4.7±1.1; HAS-BLED: 3.7±0.7) underwent percutaneous closure of the LAA patency via embolization coils. Trans-esophageal echocardiography (TEE) was performed at 60±15 days post-procedure. Results: LAA closure had been previously attempted with a Watchman device in 62 patients, and a LARIAT in 3. Baseline TEE documented a moderate or severe leak in 14 (21.5%) and 51 (78.5%) patients, respectively. Procedure and fluoroscopy times were 69±37min and 22±15min, respectively; the mean volume of iodinated contrast medium used was 82±43mL. Coil deployment was successful in all cases [median n. of coils attempted: 3 (IQR:2-5); median n. of coils deployed: 3 (IQR: 2-4)]. The overall complication rate was 3.1% (1 pericardial tamponade, 1 pericardial effusion). Peri-procedural angiographic and TEE outcomes demonstrated complete obliteration or a negligible residual opacification with a trivial residual jet in 62 cases (95.4%), and a partial occlusion with moderate residual jet in 3 (6.4%). Follow-up TEE after 67±12 days revealed complete LAA sealing or a negligible residual leak in 63 cases (96.9%). Coil deployment led to an average reduction of 90.1% in leak size (p<0.001). After an overall follow-up of 17±4 months, no TE events were documented; 3 patients died from non-cardiovascular and one from cardiovascular causes (heart failure). Conclusions: Transcatheter LAA leak occlusion via endovascular coils appears to be a safe, effective, and promising approach in high TE-risk patients with incomplete LAA closure.


2021 ◽  
Vol 77 (18) ◽  
pp. 2486
Author(s):  
Ravi A. Thakker ◽  
Abraham Lee ◽  
Benjamin Greiner ◽  
Lin Gao ◽  
Masood Ahmad ◽  
...  

Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S193-S194
Author(s):  
Kristin Babb ◽  
Emrie D. Tomaiko ◽  
Carla Lockhart ◽  
J. Peter Weiss ◽  
H. Kenith Fang ◽  
...  

Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S126
Author(s):  
Ciro Ascione ◽  
Marco Bergonti ◽  
Valentina Catto, Stefania I. Riva ◽  
Massimo Moltrasio ◽  
Fabrizio Tundo ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document