scholarly journals TOTAL OCCLUSION OF RIGHT MAIN PULMONARY ARTERY IN A PATIENT WITH SEVERE PULMONARY HYPERTENSION

2021 ◽  
Vol 77 (18) ◽  
pp. 2789
Author(s):  
Cynthia Jackson-Pedroza ◽  
Oscar Garcia-Padron ◽  
Leticia Gallardo Grajeda ◽  
Carlos Dattoli-Garcia ◽  
Fabio Solis-Jimenez ◽  
...  
2020 ◽  
Vol 2 (2) ◽  
Author(s):  
Eapen Thomas ◽  
Sunny Zacharias ◽  
Madan Mohan Maddali ◽  
Pranav Subbaraya Kandachar ◽  
Nishant Ram Arora ◽  
...  

2021 ◽  
Vol 70 (Suppl-4) ◽  
pp. S762-67
Author(s):  
Ahsan Beg ◽  
Abdul Malik ◽  
Amjad Mahmood ◽  
M Younas ◽  
Fakher -e- Fayaz

Objective: To find the mean pulmonary artery pressures (PAP) in adults (>12 years) Patent Ductus Arteriosus (PDA) with ‘reversible pulmonary hypertension’ after the device closure. Residual PDA and immediate complications (embolization, pulse loss, obstruction in the aorta or pulmonary artery) are to be reported. Study Design: Retrospective study. Place and Duration of Study: Tertiary Care Referral Hospital, from Aug 2007 to Jun 2020. Methodology: This retrospective study is descriptive. Data collected by convenience sampling from 3 tertiary care referral hospital. 981 patients were undergone PDA device closure during the period from Aug 2007 to June 2020. After informed consent, an initial assessment was done by history, clinical examination, x-ray chest PA view, electrocardiography (ECG), and transthoracic echocardiography (TTE). Reversible pulmonary hypertension was labeled based on non-invasive criteria including room air saturation >93% and cardiomegaly on x-ray chest. Patients who had <93% and normal heart size on x-ray chest were excluded. The lower limit for age was 12 years. Results: Nine Hundred Eighty One patients had undergone PDA device closure. 32 (n=32/981 3.3%) had fulfilled our inclusion criteria. The mean age was 22 ± 9 (13–45) years. Mean weight was 41 ± 11 (25-66) kg. Successful device closure was done in 30 patients (93.7%). Mean diameter of PDA was 7 ± 0.1 (4.5-13 mm. Mean PAP decreased from 59 ± 13 mmHg to 38 ± 19 mmHg (p<0.05). Commonest device used was Shasma duct occluder (n=16/32 50%) followed by Occlutech Duct Occluder (n=7/32 21.9%), while 2 had muscular VSD device (n=5/32 15.6%). In 2 patients, there was an underestimation of the size of PDA so the device was retrieved and replaced with another larger one successfully. Two patients had the device fully dropped into the main pulmonary artery before it was released. Larger size device was not available at that time so the patients were referred for surgery. None of our patients had device embolization or residual shunt on echo performed next day to the procedure. Neither any patient had residual pulmonary hypertension on echocardiography. There was no significant obstruction in the aorta in any patients. Two patients had mild left pulmonary artery obstruction. There was no significant obstruction in the aorta in any of our patients. There was pulse loss in 3 patients which were treated successfully with heparin infusion with no residual damage. Conclusion: Device closure is a feasible option in adults with hypertensive PDA while the decision of reversibility is based on non-invasive criteria.


Surgery Today ◽  
2019 ◽  
Vol 50 (3) ◽  
pp. 275-283
Author(s):  
Hidenao Kayawake ◽  
Akihiro Aoyama ◽  
Hideyuki Kinoshita ◽  
Tomoya Yoneda ◽  
Shiro Baba ◽  
...  

2019 ◽  
Vol 29 (5) ◽  
pp. 704-707 ◽  
Author(s):  
Roopesh Singhal

AbstractUnilateral interruption of pulmonary artery is a rare congenital anomaly which is usually associated with other congenital heart disease. Even more rarely it may occur in isolation. Most of the cases are incidentally detected in adulthood. Some cases develop pulmonary hypertension for yet unknown reasons; such cases usually present in infancy with right heart failure. Surgical correction in such cases is associated with adverse outcomes. Heart lung transplantation should be considered in such patients. We report a 3-year-old boy with interruption of right pulmonary artery with severe pulmonary hypertension and right heart failure who was considered for heart lung transplantation.


Author(s):  
Megan J Chambers ◽  
Mitchel J Colebank ◽  
M Umar Qureshi ◽  
Rachel Clipp ◽  
Mette S Olufsen

Detection and monitoring of patients with pulmonary hypertension, defined as a mean blood pressure in the main pulmonary artery above 25 mmHg, requires a combination of imaging and hemodynamic measurements. This study demonstrates how to combine imaging data from microcomputed tomography images with hemodynamic pressure and flow waveforms from control and hypertensive mice. Specific attention is devoted to developing a tool that processes computed tomography images, generating subject-specific arterial networks in which one-dimensional fluid dynamics modeling is used to predict blood pressure and flow. Each arterial network is modeled as a directed graph representing vessels along the principal pathway to ensure perfusion of all lobes. The one-dimensional model couples these networks with structured tree boundary conditions representing the small arteries and arterioles. Fluid dynamics equations are solved in this network and compared to measurements of pressure in the main pulmonary artery. Analysis of microcomputed tomography images reveals that the branching ratio is the same in the control and hypertensive animals, but that the vessel length-to-radius ratio is significantly lower in the hypertensive animals. Fluid dynamics predictions show that in addition to changed network geometry, vessel stiffness is higher in the hypertensive animal models than in the control models.


Sign in / Sign up

Export Citation Format

Share Document