Experimental results of functional performance of a vacuum vessel pressure suppression system in ITER

2002 ◽  
Vol 63-64 ◽  
pp. 217-222 ◽  
Author(s):  
Mitsuhiko Shibata ◽  
Kazuyuki Takase ◽  
Hironori Watanabe ◽  
Hajime Akimoto
2021 ◽  
Vol 171 ◽  
pp. 112523
Author(s):  
A. Pesetti ◽  
A. Marini ◽  
M. Raucci ◽  
G. Giambartolomei ◽  
M. Olcese ◽  
...  

2020 ◽  
Vol 153 ◽  
pp. 111485
Author(s):  
Keelan Keogh ◽  
Chang-Hwan Choi ◽  
David Cooper ◽  
Steven Craig ◽  
David Hamilton ◽  
...  

Author(s):  
Dahmane Mazed ◽  
Rosa Lo Frano ◽  
Donato Aquaro ◽  
Daniele Del Serra ◽  
Igor Sekachev ◽  
...  

The Vacuum Vessel Pressure Suppression System (VVPSS), a key safety system of the ITER plant, is designed to protect the Vacuum Vessel (VV) from over pressure occurring in the case of LOCA (Loss Of Coolant Accident) or other pressurizing accidents such as LOVA (Loss Of Vacuum Accident). The steam condensation in the Suppression Tanks (main elements of the VVPSS system), occurs at sub-atmospheric pressure. The steam condensation, at pressures equal or greater than the atmospheric, has been numerically analyzed and experimentally investigated in the past in order to optimize the design of the pressure suppression system of boiling water nuclear reactors. However, very limited experimental data is available concerning the steam condensation in a water tank at sub-atmospheric pressure. In order to analyze the steam condensation in these operating conditions, an experimental study, funded by ITER Organization, is conducted at the Department of Civil and Industrial Engineering (DICI) of University of Pisa. The tests analyze the condensation of saturated or superheated steam at sub-atmospheric pressures (4.2 kPa and slightly above the water vapour saturation pressure), and pool temperature up to 50°C at several heights of water head. The experimental facility, to perform this study, has been set up with a significant scaling factor regarding the full size installation at ITER. In this paper the experimental rig, the conditions of the experiments, and the test matrix are presented. The temperature and pressure measurements with details of the data acquisition system are described. The tests were performed at different patterns of the sparger exit holes (1, 3 and 9) and for three steam mass flow rates per one hole. The results show very high efficiency of condensation for all examined conditions. Finally, a comparison between the condensation regimen at sub-atmospheric and at atmospheric pressure is discussed.


2021 ◽  
Vol 173 ◽  
pp. 112875
Author(s):  
Chang-Hwan Choi ◽  
Shanshuang Shi ◽  
Taku Yokoyama ◽  
Christopher Hall ◽  
Keelan Keogh ◽  
...  

Author(s):  
Lorenzo Basili ◽  
Rosa Lo Frano ◽  
Marco Olcese ◽  
Igor Sekachev ◽  
Donato Aquaro

The aim of the paper is to investigate the thermal conditions (temperature distribution, heat losses) in the support system of the Vapour Suppression Tank (VST) of the Vacuum Vessel Pressure Suppression System (VVPSS), a safety important system of ITER fusion reactor, protecting the Vacuum Vessel (VV) against overpressures. The VVPSS includes four VSTs of identical volume and mounted as two stacked assemblies. The study focuses on the optimization of the design of the thermal insulation of the bottom part of the VST, connecting each two-tank stack to the basement, and also on the identification of the thermal loads at the interface between the tank support and the tank pressure boundary. A Computational Fluid Dynamics (CFD) analysis of the VST has been performed for four different insulation configurations and considering both steady state and transient loads following accidental conditions. The results of the analysis are used to provide recommendation on the optimum configuration of the thermal insulation. Measures for minimization of the thermal gradient in the critical area of the joint between the tank hemispherical head and support skirt to limit the thermal fatigue on the welds are also suggested.


1998 ◽  
Vol 42 (1-4) ◽  
pp. 61-66 ◽  
Author(s):  
Ryoichi Kurihara ◽  
Toshio Ajima ◽  
Tomoaki Kunugi ◽  
Kazuyuki Takase ◽  
Mitsuhiko Shibata ◽  
...  

2020 ◽  
Vol 7 (1) ◽  
Author(s):  
Lorenzo Basili ◽  
Rosa Lo Frano ◽  
Marco Olcese ◽  
Igor Sekachev ◽  
Donato Aquaro

Abstract The aim of the paper is to present the results of the investigation of the thermal conditions (temperature distribution, heat losses) in the support system of the vapor suppression tank (VST) of the vacuum vessel pressure suppression system (VVPSS), a safety important system of ITER fusion reactor, protecting the vacuum vessel (VV) against overpressures. The VVPSS includes four VSTs of identical volume and installed as two stacked assemblies. The study focuses on the optimization of the design of the thermal insulation at the bottom of the VSTs, interfacing with the basement and also on the identification of the thermal loads at the interface between the tank support and the tank pressure boundary. A computational fluid dynamics (CFD) analysis of the VST has been performed for four different insulation configurations and considering both steady-state and transient loads following accidental conditions. The results of the analysis are used to provide recommendation on the optimum configuration of the thermal insulation. Measures for minimization of the thermal gradient in the critical area of the joint between the tank hemispherical head and support skirt to limit the thermal fatigue on the welds are also suggested.