scholarly journals P-163 Cardiac resynchronization by dual-site left ventricular pacing

EP Europace ◽  
2003 ◽  
Vol 4 ◽  
pp. B105
Author(s):  
G NERI
EP Europace ◽  
2003 ◽  
Vol 4 (Supplement_2) ◽  
pp. B105-B105
Author(s):  
G. Neri ◽  
R. Zamprogno ◽  
G. Masaro ◽  
F. Di Gregorio

Author(s):  
Thijs Stoker ◽  
Theo J. Klinkenberg ◽  
Alexander H. Maass ◽  
Massimo A. Mariani

We describe two cases in which a biventricular implantable cardioverter defibrillator for cardiac resynchronization therapy had to be placed on the right side due to unsuitability of the left subclavian vein. Endocardial implantation of a left ventricular lead through the coronary sinus was previously attempted but was unsuccessful. Implantation of the epicardial left ventricular pacing lead was performed through video-assisted thoracic surgery on the left side. The connector end of the left ventricular pacing lead was tunnelized through the anterior mediastinum into the right pleural space. The right-sided pocket was then opened. A tunnel was created from the pocket to the thoracic wall, and the pleural space was entered over the second rib. The lead was retrieved from the right pleural space and connected with the Cardiac resynchronization therapy-device (CRT-D). Both procedures and postoperative periods were uneventful. Intrathoracic left-to-right tunneling of an epicardial left ventricular lead by video-assisted thoracic surgery is feasible and safe. It provides an alternative to subcutaneous tunneling.


2017 ◽  
Vol 2 (43) ◽  
pp. 9-13
Author(s):  
Przemysław Mitkowski

Cardiac resynchronization therapy in patients with heart failure, reduced ejection fraction and prolonged QRS duration has become standard of care. Unfortunately, despite improvements in delivery of this treatment still approximately 30% of patients are non-responders. Among causes of this phenomenon one can find an inability to deliver hemodynamically effective left ventricular pacing. There were proposed several solutions to solve the problem, including: multisite RV pacing, multisite LV pacing, multipoint LV pacing. Multisite RV pacing (two RV leads positioned in RV: apex and RVOT), although causes some hemodynamic improvement in LVEF or distance in 6MWT and reduction of LVESD or number of hospitalizations in comparison to no paced patients, but its efficacy is significantly worse than normal CRT. So it should not be considered as an alternative to CRT even to surgically placed LV lead. Multisite LV pacing (two leads iv cardiac veins) gives significant benefits over standard CRT, especially in patients with poor heart vein system, which preclude optimal LV lead placement. Clinical benefits of this mode of therapy were observed in non-responders to classical CRT, and were proved in: higher responder rates, improved EF, VO2, distance in 6MWT, reduction of NYHA class, LVESV, LVEDD and increase of dP/dt. Multipoint LV pacing (different pacing point located on the same LV lead) is encouraging way of CRT delivery and does not require any additional lead. Benefits of MP pacing over classical CRT were proved in numerous trails in acute tests by improvement in dP/dt, increase in maximal strain rate, shortening of total activation time, reduction in QRS duration and after mid- and long term follow-up in reduction of LVESV, increase in EF, reduction of asynchrony and higher percentage of responders. Multipoint left ventricular pacing should be a standard of CRT delivery in first implantations.


Sign in / Sign up

Export Citation Format

Share Document