Jump Processes Filtering Approach for the Real-time Modelling of Electric Power System Network

1990 ◽  
Vol 23 (8) ◽  
pp. 25-30
Author(s):  
E. Kliokys
2013 ◽  
Vol 385-386 ◽  
pp. 668-674
Author(s):  
Jia Yang ◽  
Hai Bao ◽  
Ling Wang ◽  
Gang Liu

Steady-state power flow calculation belongs to power system steady-state analysis, and the data used in calculation should be steady-state data. However, the existing SCADA system hasnt distinguished the transient data from the steady-state data. The real-time measured data reflect the dynamic electric power system. It is the right reason for not all of the real-time measured power can be used for power flow calculation. In another word, it causes the matching problem between measured data and power flow calculations. Based on the current situation of information collection system, the characteristics of the measured data had been analyzed in this paper. And an effective acquisition method for steady-state measured data is proposed on the theoretical basis of the law of large numbers. It uses the average value of the measured data that in the same load state to approximate the steady-state true value in one period. And the steady-state data can be used in power flow calculation. The simulation results show that the method proposed in this paper ensures the accuracy and reliability of power flow calculation.


2018 ◽  
Vol 55 (2) ◽  
pp. 3-10
Author(s):  
A. Obushevs ◽  
A. Mutule

Abstract The paper focuses on the application of synchrophasor measurements that present unprecedented benefits compared to SCADA systems in order to facilitate the successful transformation of the Nordic-Baltic-and-European electric power system to operate with large amounts of renewable energy sources and improve situational awareness of the power system. The article describes new functionalities of visualisation tools to estimate a grid inertia level in real time with monitoring results between Nordic and Baltic power systems.


2018 ◽  
Vol 3 (4) ◽  
pp. 139
Author(s):  
A A Suvorov ◽  
A S Gusev ◽  
Y S Borovikov ◽  
A O Sulaymanov ◽  
M V Andreev ◽  
...  

.


2020 ◽  
Vol 188 ◽  
pp. 00022
Author(s):  
Rusilawati Rusilawati ◽  
Irrine Budi Sulistiawati ◽  
Naoto Yorino

The capability curve for each generator unit is usually provided by the generator manufacturer. But in practice, the generator can reach its maximum generation limit before reaching the maximum limit on the generator capability curve provided by the generator manufacturer. This might occur because of the load location is far from the generator or the varying of the loading value so that the maximum generation limit is smaller than the value given on the generator capability curve of the manufacturer. In this paper, the generator capability curve is determined using the Modified Single Machine to Infinite Bus (M-SMIB) system approach to determine the maximum generation limit every time there is a change in loading or change in the load location. After the maximum generation limit of each unit generator is known, the generator capability curve that is always in accordance with the real time situation can be formed. Thus, the operation limit of each generator can be recognized, determine the appropriate protection system setting and can prevent the electric power system disturbance. This method will be applied to generator units in the four bus IEEE system with two generators.