scholarly journals Risk factors for revision after artificial urinary sphincter implantation in male patients with stress urinary incontinence

2021 ◽  
Vol 32 ◽  
pp. S72
Author(s):  
C. Manfredi ◽  
P. Krishnappa ◽  
E. Fernandez Pascual ◽  
D. Arcaniolo ◽  
C. Quattrone ◽  
...  
2017 ◽  
Vol 84 (4) ◽  
pp. 263-266 ◽  
Author(s):  
Christophe Llorens ◽  
Tobias Pottek

Study Design This is a retrospective, non-randomised study. Objectives The aim of this study was to evaluate safety and efficacy of artificial urinary sphincter ZSI 375 inserted in male patients with stress urinary incontinence (SUI). Methods Between May 2009 and January 2017, 45 men with SUI underwent ZSI 375 device insertion. Operations were performed in two French centres by one surgeon. Complications and pad used to manage continence were recorded. Results From May 2009 to January 2012, 45 patients with a mean age of 70.42 years underwent placement of the ZSI 375 device in France. The most common cause for incontinence was radical prostatectomy (RP, 33/45 ­patients, 73.33%). The minimal period of incontinence was 6 months. Twenty-seven out of 45 patients (60.00%) had a severe incontinence (at least four pads per day), 13 patients (28.89%) had moderate incontinence (three pads per day) and five patients (11.11%) had two pads per day. With a long follow-up, the ZSI 375 device was considered to be successful in 73.33% patients after 5 years (60 months) and 72% of patients after 7 years (84 months). The infection rate was 2.2 % affecting one in 45 patients. Six out of 45 patients presented a urethral erosion (13.33%). Mechanical failure with a revision occurred in three patients (6.67%). Conclusions The ZSI 375 device is a safe and effective device to treat severe SUI in men.


2017 ◽  
Vol 84 (3) ◽  
pp. 148-152 ◽  
Author(s):  
Ireneusz Ostrowski ◽  
Mariusz Blewniewski ◽  
Frank Neugart ◽  
Burkhard von Heyden ◽  
Oscar Selvaggio ◽  
...  

Objectives The aim of this study was to evaluate the safety and efficacy of the artificial urinary sphincter ZSI 375 device in male patients with stress urinary incontinence (SUI) at 10 centres. Methods This was a retrospective, nonrandomised, multicentre study. From January 2012 to December 2014, and follow-up to February 2016, men with SUI were treated with the ZSI 375 device. The primary outcome was continence. The secondary outcome was complications rate. Results A total of 147 patients with moderate-to-severe stress incontinence and mean age of 70.67 (26-85) years underwent implantation of the ZSI 375 device at 10 centres. The most common indication for placement was incontinence after radical prostatectomy (121 patients: 82.31%). The ZSI 375 device was considered successful in 86.40% of cases after 12 months follow-up, 83.52% after 24 months follow-up and 78.26% after 36 months follow-up. The infection rate was 6.12%, urethral erosion was 12.92% and mechanical failure was limited to 3.40% leading to ZSI 375 improvement. Conclusions This study confirmed safety and efficacy of ZSI 375 device to treat moderate-to-severe SUI in men.


Sign in / Sign up

Export Citation Format

Share Document