Time-resolved fluorescence immunoassay with measurement of a europium chelate in solution: dissociation conditions and application for determination of cortisol

1994 ◽  
Vol 66 (15) ◽  
pp. 2590-2594 ◽  
Author(s):  
Xiao-Da. Yang ◽  
Weng-Bao. Chang ◽  
Yun-Xiang. Ci
1989 ◽  
Vol 35 (4) ◽  
pp. 555-559 ◽  
Author(s):  
G Barnard ◽  
F Kohen ◽  
H Mikola ◽  
T Lövgren

Abstract We describe a liquid-phase nonseparation time-resolved fluorescence immunoassay for measuring estrone-3-glucuronide in undiluted urine. The sensitivity, specificity, and accuracy are similar to those for a conventional separation fluoroimmunoassay or radioimmunoassay, but the speed, convenience, precision, reliability, and clinical utility of the new method are more advantageous. The labeled antigen, a fluorescent europium chelate covalently linked to estrone-3-glucuronide, is incubated for 10 min with a limited concentration of polyclonal or monoclonal antibodies to estrone-3-glucuronyl-6-bovine serum albumin and 10 microL of standard or sample (undiluted urine) in microtiter wells. The fluorescence emanating from the antibody-free label, which is proportional to the concentration of estrone-3-glucuronide in the standard or sample, is then measured in a time-resolved fluorometer. The method is useful for monitoring ovarian function in women.


2013 ◽  
Vol 40 (7) ◽  
pp. 1114-1117
Author(s):  
Yuan LIU ◽  
Rong-Rong LIU ◽  
Xian-Jin Liu ◽  
Dun-Huang Fang ◽  
Cun-Man Song ◽  
...  

2016 ◽  
Vol 22 (2) ◽  
pp. 130-135 ◽  
Author(s):  
Ling Wang ◽  
Mujuan Xu ◽  
Ruolan Huang ◽  
Xiao Chang ◽  
Cuicui Chen ◽  
...  

The aim of this study was to establish a dual-label time-resolved fluorescence immunoassay (TRFIA) for the simultaneous determination of cardiac troponin T (cTnT) and myoglobin (MYO) for the early diagnosis of acute myocardial infarction. The sandwich immunoassay was used to detect the concentration of cTnT and MYO in serum. cTnT and MYO in serum were captured by anti-cTnT and anti-MYO antibodies immobilized on microtiter wells and then banded together with another anti-cTnT and anti-MYO labeled with europium(III) Sm3+ and samarium(III) Eu3+ chelates, followed by fluorescence measurement using time-resolved fluorometry. The performance of this TRFIA was evaluated using the clinical serum and compared with the commercial assays. The linear correlation coefficients ( R2) of the cTnT and MYO standard curves were 0.9993 and 0.9995, respectively. The sensitivity for cTnT detection was 2.21 pg/mL (linear dynamic range was 3.24–963.71 pg/mL), and the average recovery was 100.57%. The sensitivity for MYO detection was 3.24 ng/mL (linear dynamic range was 4.95–976.85 ng/mL), and the average recovery was 99.79%. High correlation coefficients ( R2) were obtained between the commercial assays and dual-label TRFIA ( R2 = 0.999). The present dual-label TRFIA has high sensitivity, specificity, and accuracy in clinical sample analysis. It is a good alternative to the single-label diagnostic methods.


1991 ◽  
Vol 37 (9) ◽  
pp. 1486-1491 ◽  
Author(s):  
E P Diamandis

Abstract A new time-resolved fluorescence immunoassay system involving use of the europium chelate of 4,7-bis(chlorosulfophenyl)-1,10-phenanthroline-2,9-dicarboxylic acid as label is reviewed. This stable chelate by itself is not very fluorescent but, used in multiple labeling strategies, improves the achievable detection limits. By using multiple labeling, streptavidin tailing, and Eu3+ activation, one can create a very stable, easy-to-use reagent that is suitable for devising highly sensitive immunoassays and other biotechnological assays. This reagent, a streptavidin-based macromolecular complex, is able to detect approximately 300,000 molecules (approximately 0.5 amol) of alpha-fetoprotein in a model noncompetitive immunoassay.


1990 ◽  
Vol 36 (3) ◽  
pp. 503-508 ◽  
Author(s):  
I Kahan ◽  
A Papanastasiou-Diamandi ◽  
G Ellis ◽  
S K Makela ◽  
J McLaurin ◽  
...  

Abstract We describe a new "sandwich"-type non-isotopic immunoassay for human somatotropin (GH, growth hormone) in serum. In the assay, GH is captured by a monoclonal antibody immobilized in a white microtiter well and simultaneously reacted with a second biotinylated monoclonal antibody. The degree of binding of biotinylated antibody, which increases with increasing amount of GH in the sample, is quantified by adding streptavidin labeled with the europium chelate of 4.7 - bis(chlorosulfophenyl) - 1.10 - phenanthroline - 2.9 - dicarboxylic acid. The fluorescent complex on the solid phase is then measured by excitation at 337.1 nm (nitrogen laser) and monitoring the emission at 615 nm in a gated fluorometer/analyzer. The proposed procedure has short incubation times (less than 4 h protocol), uses only 25 microL of serum per microtiter well, and gives precise and accurate results. The method was clinically evaluated with samples obtained from pediatric patients undergoing investigation for growth abnormalities and from a patient with acromegaly.