scholarly journals all the speed and convenience of a single pan analytical balance with a complete digital readout system-at anew low cost.

1965 ◽  
Vol 43 (3) ◽  
pp. 8
2021 ◽  
Author(s):  
Samantha Richardson ◽  
Samira Al Hinai ◽  
Jesse Gitaka ◽  
Will Mayes ◽  
Mark Lorch ◽  
...  

<p>Routine monitoring of available soil nutrients is required to better manage agricultural land<sup>1</sup>, especially in many lower and middle income countries (LMICs). Analysis often still relies on laboratory-based equipment, meaning regular monitoring is challenging.<sup>2</sup> The limited number of in situ sensors that exist are expensive or have complex workflows, thus are not suitable in LMICs, where the need is greatest.<sup>3</sup> We aim to develop a simple-to-use, low-cost analysis system that enable farmers to directly monitor available nutrients and pH on-site, thus making informed decisions about when and where to apply fertilisers.</p><p>We combine nutrient extraction via a cafetiere-based filtration system with nutrient readout on a paper microfluidic analysis device (PAD) employing colour producing reactions that can be captured via a smartphone camera through an app. Image analysis of colour intensity permits quantitation of analytes. We initially focus on key nutrients (phosphate, nitrate) and pH analysis.</p><p>For extraction of phosphate, we mixed soil and water in the cafetiere and quantified the extracted phosphate via phosphomolybdenum blue chemistry. For example, for 5 g of soil, a water volume of about 160 mL led to optimum extraction. Active mixing, by pushing coffee filter plunger up and down, aided extraction. A mixing period of 3 min yielded maximum extraction; this time period was deemed suitable for an on-site workflow.</p><p>Following nutrient extraction, a simple-to-use readout system is required. For this, we developed colourimetric paper-based microfluidic devices; these are simply dipped into the decanted soil supernatant from the cafetiere and wick fluids based on capillary forces. Chemical reagents are pre-stored in reaction zones, created by patterning cellulose with wax barriers. Our devices contain multiple paper layers with different reagents; these are folded, laminated and holes cut for sample entry. Following the required incubation time, the developed colour is captured using a smartphone. This constitutes a portable detector, already available to envisaged end users, even in LMICs. We have previously developed an on-paper reaction for monitoring phosphates in fresh water in the mg L<sup>-1</sup> working range, with readout after an incubation period of 3 min. This method was adapted here to enable storage at ambient temperatures up to 1 week by incorporating additional acidic reagents. Further pad devices were developed in our group for colour-based readout of nitrate, involving a two-step reaction chemistry. Within a relatively short incubation period (≤8 min) a pink coloured was formed following reduction of nitrate to nitrite with zinc and subsequent reaction to form an azo-dye. This system achieved detection in the low mg L<sup>-1</sup> range. Moreover, a pad to monitor pH was developed, employing chlorophenol red indicator, with linear response achieved over the relevant pH 5-7 range.  </p><p>Our analysis workflow combines a simple-to-use cafetiere-based extraction method with paper microfluidic colour readout and smart-phone detector. This has the potential to enable farmers to monitor nutrients in soils on-site. Future work will aim at integrating multiple analytes into a single analysis card and to automate image analysis.</p><p>[1] <em>Europ. J. Agronomy</em>, 55, 42–52, <strong>2014.</strong></p><p>[2] <em>Nutr. Cycling Agroecosyst.,</em> 109, 77-102, <strong>2017.</strong></p><p>[3] Sens Actuators B, 30, 126855, <strong>2019.</strong></p>


2006 ◽  
Vol 1 (1) ◽  
pp. 106-110 ◽  
Author(s):  
Bin Zhou ◽  
Zhong-yu Gao ◽  
Huai Chen ◽  
Rong Zhang ◽  
Zhi-yong Chen

Author(s):  
Hung-Che Chen ◽  
Yung-Hua Kao ◽  
Paul C.-P. Chao ◽  
Chin-Long Wey

The design of the proposed readout circuit provides benefits of detection speed, portability, low-cost and less human operational errors compared with the measurement by traditional instruments. Thus the added value is brought for biosensors and applied in home care. A novel readout circuit for a gas sensor based on an organic diode with vertical nano-junctions (VNJ) is proposed in this study. There are seven parts included in the readout system. First part is a preamplifier, second part is a peak-detect-and-hold circuit, third part is a divider, fourth part is the saturation detector, fifth part is the auto-reset circuit, sixth part is a logic gate and a buffer, seventh part is a micro-processor control unit (MCU). STM32 is the CPU of proposed MCU by ALIENTEK. The ADC of MCU is used to transform the output data of readout circuit. The designed circuit is accomplished by Taiwan Semiconductor Manufacturing Company (TSMC) 0.35 μm 2P4M 3.3 V mixed signal CMOS process, the area of chip is 0.74×0.75 mm2. Finally, the differences between experimental results with post-simulation results in 10 ppb ∼ 3 ppm of ammonia, the differences are within 7.24%. The sensing system is able to detect minimum ammonia concentration of 10 ppb, while the maximum one reaches around 3 ppm.


1976 ◽  
Vol 16 (3) ◽  
pp. 371-373 ◽  
Author(s):  
Edgar A. Deyoe ◽  
Hilliard G. Foster

Sign in / Sign up

Export Citation Format

Share Document