Hydrophilic Pyrazine Dyes as Exogenous Fluorescent Tracer Agents for Real-Time Point-of-Care Measurement of Glomerular Filtration Rate

2011 ◽  
Vol 54 (14) ◽  
pp. 5048-5058 ◽  
Author(s):  
Raghavan Rajagopalan ◽  
William L. Neumann ◽  
Amruta R. Poreddy ◽  
Richard M. Fitch ◽  
John N. Freskos ◽  
...  
2012 ◽  
Vol 20 (8) ◽  
pp. 2490-2497 ◽  
Author(s):  
Amruta R. Poreddy ◽  
William L. Neumann ◽  
John N. Freskos ◽  
Raghavan Rajagopalan ◽  
Bethel Asmelash ◽  
...  

Author(s):  
Sean Currin ◽  
Mwawi Gondwe ◽  
Nokthula Mayindi ◽  
Shingirai Chipungu ◽  
Bongekile Khoza ◽  
...  

Abstract Objectives The prevalence of chronic kidney disease is rising rapidly in low- and middle-income countries. Serum creatinine and estimation of glomerular filtration rate (GFR) are critical diagnostic tools, yet access to centralised laboratory services remains limited in primary care resource-limited settings. The aim of this study was to evaluate point-of-care (POC) technologies for serum creatinine measurement and to compare their performance to a gold standard measurement using iohexol measured GFR (mGFR). Methods POC creatinine was measured using iSTAT® and StatSensor® devices in capillary and venous whole blood, and laboratory creatinine was measured using the compensated kinetic Jaffe method in 670 participants from a rural area in South Africa. GFR estimating equations Chronic Kidney Disease Epidemiology Collaboration and Modification of Diet in Renal Disease (CKD-EPI and MDRD) for POC and laboratory creatinine were compared to iohexol mGFR. Results Calculated GFR for laboratory and POC creatinine measurements overestimated GFR (positive bias of 1.9–34.1 mL/min/1.73 m2). However, all POC devices had less positive bias than the laboratory Jaffe method (1.9–14.7 vs. 34.1 for MDRD, and 8.4–19.9 vs. 28.6 for CKD-EPI). Accuracy within 30% of mGFR ranged from 0.56 to 0.72 for POC devices and from 0.36 to 0.43 for the laboratory Jaffe method. POC devices showed wider imprecision with coefficients of variation ranging from 4.6 to 10.2% compared to 3.5% for the laboratory Jaffe method. Conclusions POC estimated GFR (eGFR) showed improved performance over laboratory Jaffe eGFR, however POC devices suffered from imprecision and large bias. The laboratory Jaffe method performed poorly, highlighting the need for laboratories to move to enzymatic methods to measure creatinine.


2020 ◽  
Vol 24 (39) ◽  
pp. 1-248
Author(s):  
Mark Corbett ◽  
Ana Duarte ◽  
Alexis Llewellyn ◽  
James Altunkaya ◽  
Melissa Harden ◽  
...  

Background Patients with low estimated glomerular filtration rates may be at higher risk of post-contrast acute kidney injury following contrast-enhanced computed tomography imaging. Point-of-care devices allow rapid measurement of estimated glomerular filtration rates for patients referred without a recent estimated glomerular filtration rate result. Objectives To assess the clinical effectiveness and cost-effectiveness of point-of-care creatinine tests for outpatients without a recent estimated glomerular filtration rate measurement who need contrast-enhanced computed tomography imaging. Methods Three systematic reviews of test accuracy, implementation and clinical outcomes, and economic analyses were carried out. Bibliographic databases were searched from inception to November 2018. Studies comparing the accuracy of point-of-care creatinine tests with laboratory reference tests to assess kidney function in adults in a non-emergency setting and studies reporting implementation and clinical outcomes were included. Risk of bias of diagnostic accuracy studies was assessed using a modified version of the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Probabilities of individuals having their estimated glomerular filtration rates correctly classified were estimated within a Bayesian framework and pooled using a fixed-effects model. A de novo probabilistic decision tree cohort model was developed to characterise the decision problem from an NHS and a Personal Social Services perspective. A range of alternative point-of-care testing approaches were considered. Scenario analyses were conducted. Results Fifty-four studies were included in the clinical reviews. Twelve studies reported diagnostic accuracy for estimated glomerular filtration rates; half were rated as being at low risk of bias, but there were applicability concerns for most. i-STAT (Abbott Point of Care, Inc., Princeton, NJ, USA) and ABL (Radiometer Ltd, Crawley, UK) devices had higher probabilities of correctly classifying individuals in the same estimated glomerular filtration rate categories as the reference laboratory test than StatSensor® devices (Nova Biomedical, Runcorn, UK). There was limited evidence for epoc® (Siemens Healthineers AG, Erlangen, Germany) and Piccolo Xpress® (Abaxis, Inc., Union City, CA, USA) devices and no studies of DRI-CHEM NX 500 (Fujifilm Corporation, Tokyo, Japan). The review of implementation and clinical outcomes included six studies showing practice variation in the management decisions when a point-of-care device indicated an abnormal estimated glomerular filtration rate. The review of cost-effectiveness evidence identified no relevant studies. The de novo decision model that was developed included a total of 14 strategies. Owing to limited data, the model included only i-STAT, ABL800 FLEX and StatSensor. In the base-case analysis, the cost-effective strategy appeared to be a three-step testing sequence involving initially screening all individuals for risk factors, point-of-care testing for those individuals with at least one risk factor, and including a final confirmatory laboratory test for individuals with a point-of-care-positive test result. Within this testing approach, the specific point-of-care device with the highest net benefit was i-STAT, although differences in net benefit with StatSensor were very small. Limitations There was insufficient evidence for patients with estimated glomerular filtration rates < 30 ml/minute/1.73 m2, and on the full potential health impact of delayed or rescheduled computed tomography scans or the use of alternative imaging modalities. Conclusions A three-step testing sequence combining a risk factor questionnaire with a point-of-care test and confirmatory laboratory testing appears to be a cost-effective use of NHS resources compared with current practice. The risk of contrast causing acute kidney injury to patients with an estimated glomerular filtration rate of < 30 ml/minute/1.73 m2 is uncertain. Cost-effectiveness of point-of-care testing appears largely driven by the potential of point-of-care tests to minimise delays within the current computed tomography pathway. Future work Studies evaluating the impact of risk-stratifying questionnaires on workflow outcomes in computed tomography patients without recent estimated glomerular filtration rate results are needed. Study registration This study is registered as PROSPERO CRD42018115818. Funding This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 24, No. 39. See the NIHR Journals Library website for further project information.


2013 ◽  
Author(s):  
Richard B. Dorshow ◽  
Richard M. Fitch ◽  
Karen P. Galen ◽  
Jolette K. Wojdyla ◽  
Amruta R. Poreddy ◽  
...  

2019 ◽  
Vol 499 ◽  
pp. 123-127 ◽  
Author(s):  
Violeta Stojkovic ◽  
Pierre Delanaye ◽  
Gregory Collard ◽  
Nunzio Ferrante ◽  
Caroline Le Goff ◽  
...  