scholarly journals Predictive Value for Mortality of the Double Product at Rest Obtained by Home Blood Pressure Measurement: The Ohasama Study

2012 ◽  
Vol 25 (5) ◽  
pp. 568-575 ◽  
Author(s):  
R. Inoue ◽  
T. Ohkubo ◽  
M. Kikuya ◽  
H. Metoki ◽  
K. Asayama ◽  
...  
Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Deuk-Young Nah ◽  
Jin-Wook Chung ◽  
Jun-Ho Bae ◽  
Dong-Seok Lee ◽  
Moo-Yong Rhee

Introduction: The major hypertension guidelines suggest methods for diagnosing hypertension by measuring the 24-hour ambulatory blood pressure (ABP) or home blood pressure (HBP) if hypertension is suspected. Hypothesis: there is no consensus of cut off values for HBP as the criterion for hypertension and also optimal duration of home blood pressure measurement (HBPM). Methods: 319 suspected hypertension patients (systolic blood pressure ≥140 mmHg or diastolic blood pressure ≥90 mmHg, average value of three times measurements of blood pressure in the office) were included in four university hospital. The blood pressure (BP) measurement taken by patients in his/her home with HBPM device (Watch BP Home, Microlife, Swiss) and measured three times with one minute interval at morning and evening for 7 days. The 24-hour ambulatory blood pressure measurement (ABPM) was performed by Mobil-O-Graph (IEM. GmbH, Germany). The device was set to obtain BP readings at 30-minute intervals during the day and night. The definition of hypertension was as follows, SBP ≥135 mmHg or DBP ≥85 mmHg for HBPM and SBP ≥130 mmHg or DBP ≥85 mmHg for ABPM. For the analysis for diagnostic accuracy of HBPM, we used ABPM as a reference standard for the diagnosis of hypertension. Results: We decided to exclude 53 patients due to dropout or lack of valid BP measurement (valid leadings <70% of tried measurements of ABPM and less than 5-days HBPM). Finally we analyzed BP measurement data of 266 patients. Dropout or invalid BP measurement was more common in ABPM than HBPM. HBP was measured at least 6 days in more than 90% patients and white coat hypertension was diagnosed more frequently in the HBPM. HBPM had a more than 98.6% positive predictive value and 46.8% negative predictive value for the diagnosis of hypertension when put the criteria on ABPM. There are no difference of diagnostic accuracy for the diagnosis of hypertension according to the 5-day, 6-day and 7-day HBPM. Conclusions: A 5-day HBPM is enough for the diagnosis of hypertension considering ABPM as a reference. The cut off value of hypertension in HBPM is same to the current guideline values (135/85 mmHg) in this study. HBPM is an effective and available method for the diagnosis of hypertension in suspected hypertensive patients.


1997 ◽  
Vol 20 (3) ◽  
pp. 167-174 ◽  
Author(s):  
Mariko Sakuma ◽  
Yutaka Imai ◽  
Ichiro Tsuji ◽  
Kenichi Nagai ◽  
Takayoshi Ohkubo ◽  
...  

2005 ◽  
Vol 12 (3) ◽  
pp. 156
Author(s):  
C. Cuspidi ◽  
S. Meani ◽  
L. Lonati ◽  
V. Fusi ◽  
G. Magnaghi ◽  
...  

2016 ◽  
Vol 38 (8) ◽  
pp. 673-679 ◽  
Author(s):  
Silvia Di Monaco ◽  
Franco Rabbia ◽  
Michele Covella ◽  
Chiara Fulcheri ◽  
Elena Berra ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document