scholarly journals Risk factors for radiation pneumonitis after rotating gantry intensity-modulated radiation therapy for lung cancer

2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Saori Tatsuno ◽  
Hiroshi Doi ◽  
Wataru Okada ◽  
Eri Inoue ◽  
Kiyoshi Nakamatsu ◽  
...  

AbstractThe risk factors for severe radiation pneumonitis (RP) in patients with lung cancer who undergo rotating gantry intensity-modulated radiation therapy (IMRT) using volumetric modulated arc therapy (VMAT) or helical tomotherapy (HT) are poorly understood. Fifty-two patients who received rotating gantry IMRT for locally advanced lung cancer were included in this retrospective study. In total, 31 and 21 patients received VMAT and HT, respectively. The median follow-up duration was 14 months (range, 5.2–33.6). Twenty (38%) and eight (15%) patients developed grade ≥ 2 and ≥ 3 RP, respectively. In multivariate analysis, lung V5 ≥ 40% was associated with grade ≥ 2 RP (P = 0.02), and past medical history of pneumonectomy and total lung volume ≤ 3260 cc were independently associated with grade ≥ 3 RP (P = 0.02 and P = 0.03, respectively). Rotating gantry IMRT was feasible and safe in patients with lung cancer undergoing definitive radiotherapy. Reducing lung V5 may decrease the risk of symptomatic RP, and care should be taken to avoid severe RP after radiotherapy in patients with a past medical history of pneumonectomy and small total lung volume.

2017 ◽  
Vol 17 (1) ◽  
pp. 6-11 ◽  
Author(s):  
Sara Rosas ◽  
Bárbara Barbosa ◽  
José G. Couto

AbstractPurposeThis study aimed to compare intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) regarding plan quality and healthy lung sparing, in stage III non-small cell lung cancer (NSCLC) patients.Materials and methodsThe plans of 60 patients were allocated either to the IMRT (n=30) or the VMAT (n=30) group. The dose prescribed to the planning target volume (PTV) was evaluated at the 95% level and the mean lung dose (MLD) and the healthy lung receiving 5, 10 and 20 Gy (V5, V10 and V20, respectively) were analysed. The normal tissue complication probability (NTCP) for radiation pneumonitis was calculated with the Lyman–Kutcher–Burman model.ResultsBoth techniques achieved comparable results for target coverage (V95%=97·87 versus 97·18%, p>0·05) and homogeneity. The MLD (15·57 versus 16·98 Gy, p>0·05), V5 (60·35 versus 67·25%, p>0·05) and V10 (45·22 versus 53·14%, p=0·011) were lower for IMRT, whereas VMAT reduced V20 (26·44 versus 25·90%, p>0·05). The NTCP for radiation pneumonitis was higher for VMAT, but no statistical significance was observed (11·07 versus 12·75, p>0·05).ConclusionBoth techniques seemed suitable for NSCLC treatment, but IMRT presented better results regarding lung sparing thus being beneficial in reducing the risk of radiation-induced pneumonitis.


2017 ◽  
Vol 8 (3) ◽  
pp. 285 ◽  
Author(s):  
Virginia W Osborn ◽  
Andrea Leaf ◽  
Anna Lee ◽  
Elizabeth Garay ◽  
Joseph Safdieh ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document