scholarly journals Comparison of the efficacy of supraglottic airway devices in low-risk adult patients: a network meta-analysis and systematic review

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Chih-Jun Lai ◽  
Yi-Chun Yeh ◽  
Yu-Kang Tu ◽  
Ya-Jung Cheng ◽  
Chih-Min Liu ◽  
...  

AbstractNumerous supraglottic airway device (SADs) have been designed for adults; however, their relative efficacy, indicated by parameters such as adequacy of sealing, ease of application, and postinsertion complications, remains unclear. We conducted a systematic review and network meta-analysis to evaluate the efficacy of various SADs. We searched electronic databases for randomized controlled trials comparing at least two types of SADs published before December 2019. The primary outcomes were oropharyngeal leak pressure (OLP), risk of first-attempt insertion failure, and postoperative sore throat rate (POST). We included 108 studies (n = 10,645) comparing 17 types of SAD. The Proseal laryngeal mask airway (LMA), the I-gel supraglottic airway, the Supreme LMA, the Streamlined Liner of the Pharynx Airway, the SoftSeal, the Cobra Perilaryngeal Airway, the Air-Q, the Laryngeal Tube, the Laryngeal Tube Suction II, the Laryngeal Tube Suction Disposable, AuraGain, and Protector had significantly higher OLP (mean difference ranging from 3.98 to 9.18 cmH2O) compared with that of a classic LMA (C-LMA). The Protector exhibited the highest OLP and was ranked first. All SADs had a similar likelihood of first-attempt insertion failure and POST compared with the C-LMA. Our findings indicate that the Protector may be the best SAD because it has the highest OLP.Systematic review registration PROSPERO: CRD42017065273.

2016 ◽  
Vol 2016 ◽  
pp. 1-11 ◽  
Author(s):  
Eun Jin Ahn ◽  
Geun Joo Choi ◽  
Hyun Kang ◽  
Chong Wha Baek ◽  
Yong Hun Jung ◽  
...  

Air-Q® (air-Q) is a supraglottic airway device which can be used as a guidance of intubation in pediatric as well as in adult patients. We evaluated the efficacy and safety of air-Q compared to other airway devices during general anesthesia in pediatric patients by conducting a systematic review and meta-analysis. A total of 10 studies including 789 patients were included in the final analysis. Compared with other supraglottic airway devices, air-Q showed no evidence for a difference in leakage pressure and insertion time. The ease of insertion was significantly lower than other supraglottic airway devices. The success rate of intubation was significantly lower than other airway devices. However, fiberoptic view was better through the air-Q than other supraglottic airway devices. Therefore, air-Q could be a safe substitute for other airway devices and may provide better fiberoptic bronchoscopic view.


PLoS ONE ◽  
2019 ◽  
Vol 14 (5) ◽  
pp. e0216673
Author(s):  
Min-Soo Kim ◽  
Jin Ha Park ◽  
Ki-Young Lee ◽  
Seung Ho Choi ◽  
Hwan Ho Jung ◽  
...  

2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
Tomas Henlin ◽  
Michal Sotak ◽  
Petr Kovaricek ◽  
Tomas Tyll ◽  
Lukas Balcarek ◽  
...  

Objectives. Five different second-generation supraglottic airway devices, ProSeal LMA, Supreme LMA, i-gel, SLIPA, and Laryngeal Tube Suction-D, were studied. Operators were inexperienced users with a military background, combat lifesavers, nurses, and physicians.Methods. This was a prospective, randomized, single-blinded study. Devices were inserted in the operating room in low light conditions after induction of general anesthesia. Primary outcome was successful insertion on the first attempt while secondary aims were insertion time, number of attempts, oropharyngeal seal pressure, ease of insertion, fibre optic position of device, efficacy of ventilation, and intraoperative trauma or regurgitation of gastric contents.Results. In total, 505 patients were studied. First-attempt insertion success rate was higher in the Supreme LMA (96%), i-gel (87.9%), and ProSeal LMA (85.9%) groups than in the Laryngeal Tube Suction-D (80.6%) and SLIPA (69.4%) groups. Insertion time was shortest in the Supreme LMA (70.4 ± 32.5 s) and i-gel (74.4 ± 41.1 s) groups (p<0.001). Oropharyngeal seal pressures were higher in the Laryngeal Tube Suction-D and ProSeal LMA groups than in other three devices.Conclusions. Most study parameters for the Supreme LMA and i-gel were found to be superior to the other three tested supraglottic airway devices when inserted by novice military operators.


2018 ◽  
Vol 39 (2) ◽  
pp. 173-183 ◽  
Author(s):  
Maria Grazia Calevo ◽  
Nicola Veronese ◽  
Francesco Cavallin ◽  
Cavicchioli Paola ◽  
Massimo Micaglio ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document