Characterization of poloxamers by reversed-phase liquid chromatography

2016 ◽  
Vol 8 (13) ◽  
pp. 2812-2819 ◽  
Author(s):  
Bing Guan ◽  
Amr Ali ◽  
Haofan Peng ◽  
Weiwei Hu ◽  
Lam Raga Markely ◽  
...  

We developed a novel reversed-phase liquid chromatography method for monitoring multiple ingredients in poloxamers and evaluating their stability.

Molecules ◽  
2021 ◽  
Vol 26 (6) ◽  
pp. 1526
Author(s):  
Anthi Parla ◽  
Eirini Zormpa ◽  
Nikolaos Paloumpis ◽  
Abuzar Kabir ◽  
Kenneth G. Furton ◽  
...  

Parabens have been widely employed as preservatives since the 1920s for extending the shelf life of foodstuffs, medicines, and daily care products. Given the fact that there are some legitimate concerns related to their potential multiple endocrine-disrupting properties, the development of novel bioanalytical methods for their biomonitoring is crucial. In this study, a fabric phase sorptive extraction reversed-phase liquid chromatography method coupled with UV detection (FPSE-HPLC-UV) was developed and validated for the quantitation of seven parabens in human plasma samples. Chromatographic separation of the seven parabens and p-hydroxybenzoic acid was achieved on a semi-micro Spherisorb ODS1 analytical column under isocratic elution using a mobile phase containing 0.1% (v/v) formic acid and 66% 49 mM ammonium formate aqueous solution in acetonitrile at flow rate 0.25 mL min−1 with a 24-min run time for each sample. The method was linear at a concentration range of 20 to 500 ng mL−1 for the seven parabens under study in human plasma samples. The efficiency of the method was proven with the analysis of 20 human plasma samples collected from women subjected to breast cancer surgery and to reconstructive and aesthetic breast surgery. The highest quantitation rates in human plasma samples from cancerous cases were found for methylparaben and isobutylparaben with average plasma concentrations at 77 and 112.5 ng mL−1. The high concentration levels detected agree with previous findings for some of the parabens and emphasize the need for further epidemiological research on the possible health effects of the use of these compounds.


2021 ◽  
Vol 8 (6) ◽  
pp. 78
Author(s):  
Julian Ebner ◽  
Diana Humer ◽  
Robert Klausser ◽  
Viktor Rubus ◽  
Reinhard Pell ◽  
...  

Refolding is known as the bottleneck in inclusion body (IB) downstream processing in the pharmaceutical industry: high dilutions leading to large operating volumes, slow refolding kinetics and low refolding yields are only a few of the problems that impede industrial application. Solubilization prior to refolding is often carried out empirically and the effects of the solubilizate on the subsequent refolding step are rarely investigated. The results obtained in this study, however, indicate that the quality of the IB solubilizate has a severe effect on subsequent refolding. As the solubilizate contains chaotropic reagents in high molarities, it is commonly analyzed with sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). SDS-PAGE, however, suffers from a long analysis time, making at-line analytical implementation difficult. In this study, we established an at-line reversed phase liquid chromatography method to investigate the time-dependent quality of the solubilizate. To verify the necessity of at-line solubilization monitoring, we varied the essential solubilization conditions for horseradish peroxidase IBs. The solubilization time was found to have a major influence on subsequent refolding, underlining the high need for an at-line analysis of solubilization. Furthermore, we used the developed reversed phase liquid chromatography method for an in-process control (IPC). In conclusion, the presented reversed phase liquid chromatography method allows a proper control of IB solubilization applicable for tailored refolding.


Sign in / Sign up

Export Citation Format

Share Document