Development of a sensitive liquid–liquid extraction method for the determination of N-butyryl-l-homoserine lactone produced in a submerged membrane bioreactor by gas chromatography mass spectrometry and deuterated anthracene as the internal standard

2016 ◽  
Vol 8 (12) ◽  
pp. 2660-2665 ◽  
Author(s):  
Nouha Bakaraki ◽  
Dotse Selali Chormey ◽  
Sezgin Bakirdere ◽  
Guleda Onkal Engin

Quorum sensing is defined as the bacterial communication through sending and receiving chemical signals.

2014 ◽  
Vol 97 (4) ◽  
pp. 1061-1066 ◽  
Author(s):  
Bilal Yilmaz ◽  
Huseyin Sahin ◽  
Vedat Akba ◽  
Ali Fuat Erdem

Abstract This paper describes a GC/MS method for the determination of flurbiprofen in human plasma. Flurbiprofen and internal standard ibuprofen were extracted from plasma by using a liquid–liquid extraction method. Derivatization was carried out using N-Methyl-N-(trimethylsilyl)trifluoroacetamide. The calibration curve was linear between the concentration range of 0.10 and 5.0 μg/mL. Intraday and interday precision values for flurbiprofen in plasma were less than 5.49%, and accuracy (relative error) was better than 5.33%. The extraction recoveries of flurbiprofen from human plasma were between 93.6 and 98.6%. The LOD and LOQ of flurbiprofen were 0.03 and 0.10 μg/mL, respectively. This assay was applied to determine the pharmacokinetic parameters of flurbiprofen in healthy Turkish volunteers who had been given 100 mg of flurbiprofen.


2019 ◽  
Vol 55 (13) ◽  
pp. 2303-2312 ◽  
Author(s):  
Janiele Mayara Ferreira De Almeida ◽  
Elania Maria Fernandes Silva ◽  
Lourena Mafra Veríssimo ◽  
Nedja Suely Fernandes

2014 ◽  
Vol 97 (2) ◽  
pp. 415-420 ◽  
Author(s):  
Bilal Yilmaz ◽  
Ali Fuat Erdem

Abstract This paper describes a GC/MS method for the determination of ibuprofen in human plasma and urine. Ibuprofen and internal standard naproxen were extractedfrom plasma and urine by using a liquid–liquid extraction method. Derivatization was carried outusing N-methyl-N-(trimethylsilyl) trifluoroacetamide. Calibration curves were linear over the concentration range of 0.05–5.0 and 0.1–10.0 μg/mL for plasma and urine, respectively. Intraday and interday precision (RSD) values for ibuprofen in plasma and urine were less than 6.31%, and accuracy (relative error) was better than 12.00%. The mean recovery of ibuprofen was 89.53% for plasma and 93.73% for urine. TheLOD was 0.015 and 0.03 μg/mL and the LOQ was 0.05 and 0.1 μg/mL for plasma and urine, respectively. The method was successfully applied to blood samples from three healthy male volunteers who had been given an oral tablet of 600 mg ibuprofen.


1959 ◽  
Vol 37 (1) ◽  
pp. 20-28 ◽  
Author(s):  
G. L. Smithson ◽  
R. L. Eager ◽  
A. B. VanCleave

X-Ray fluorescence has been applied to the analysis of flotation concentrates obtained from pegmatitic uranium ores occurring in Northern Saskatchewan. Approximate uranium analyses can be obtained by direct measurement on flotation concentrates but more accurate results are obtained by using an internal standard such as strontium or yttrium. The time required for an analysis, as compared to that of conventional chemical or fluorimetric methods, is considerably reduced and flotation pilot plant operations can therefore be more effectively controlled. The method has been extended to include the analysis of sulphate leach liquors obtained from the leaching of pegmatitic ores and their flotation concentrates. Organic phases obtained in liquid – liquid extraction studies can also be rapidly analyzed for uranium by X-ray fluorescence.


Sign in / Sign up

Export Citation Format

Share Document