scholarly journals Real‐time control of shunt active power filter under distorted grid voltage and unbalanced load condition using self‐tuning filter

2014 ◽  
Vol 7 (7) ◽  
pp. 1895-1905 ◽  
Author(s):  
Samet Biricik ◽  
Soydan Redif ◽  
Özgür C. Özerdem ◽  
Shafiuzzaman K. Khadem ◽  
Malabika Basu
Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1951
Author(s):  
Mihaela Popescu ◽  
Alexandru Bitoleanu ◽  
Mihaita Linca ◽  
Constantin Vlad Suru

This paper presents the use of a three-phase four-wire shunt active power filter to improve the power quality in the Department of Industrial Electronics of a large enterprise from Romania. The specificity is given by the predominant existence of single-phase consumers (such as personal computers, printers, lighting and AC equipment). In order to identify the power quality indicators and ways to improve them, an A-class analyzer was used to record the electrical quantities and energy parameters in the point of common coupling (PCC) with the nonlinear loads for 27 h. The analysis shows that, in order to improve the power quality in PCC, three goals must be achieved: the compensation of the distortion power, the compensation of the reactive power and the compensation of the load unbalance. By using the conceived three-leg shunt active power filter, controlled through the indirect current control method in an original variant, the power quality at the supply side is very much improved. In the proposed control algorithm, the prescribed active current is obtained as a sum of the loss current provided by the DC voltage and the equivalent active current of the unbalanced load. The performance associated with each objective of the compensation is presented and analyzed. The results show that all the power quality indicators meet the specific standards and regulations and prove the validity of the proposed solution.


2017 ◽  
Vol 10 (2) ◽  
pp. 196-207 ◽  
Author(s):  
Venkata Subrahmanya Raghavendra Var Oruganti ◽  
Abdullah Saad Bubshait ◽  
Venkata Sesha Samba Siva Sarma Dhanikonda ◽  
Marcelo Godoy Simões

Author(s):  
Saifullah Khalid

A novel hybrid series active power filter to eliminate harmonics and compensate reactive power is presented and analyzed. The proposed active compensation technique is based on a hybrid series active filter using ATS algorithm in the conventional Sinusoidal Fryze voltage (SFV) control technique. This chapter discusses the comparative performances of conventional Sinusoidal Fryze voltage control strategy and ATS-optimized controllers. ATS algorithm has been used to obtain the optimum value of Kp and Ki. Analysis of the hybrid series active power filter system under non-linear load condition and its impact on the performance of the controllers is evaluated. MATLAB/Simulink results and Total harmonic distortion (THD) shows the practical viability of the controller for hybrid series active power filter to provide harmonic isolation of non-linear loads and to comply with IEEE 519 recommended harmonic standards. The ATS-optimized controller has been attempted for shunt active power filter too, and its performance has also been discussed in brief.


Sign in / Sign up

Export Citation Format

Share Document