Adaptive control of arterial oxygen pressure of newborn infants under incubator oxygen treatments

1985 ◽  
Vol 132 (5) ◽  
pp. 205 ◽  
Author(s):  
A. Sano ◽  
M. Kikucki
2012 ◽  
Vol 83 (4) ◽  
pp. 431-435 ◽  
Author(s):  
Tor Are S. Hansen ◽  
Jan Ivar Kåsin ◽  
Anne Edvardsen ◽  
Carl Christian Christensen ◽  
Anthony S. Wagstaff

PEDIATRICS ◽  
1987 ◽  
Vol 79 (4) ◽  
pp. 524-528
Author(s):  
Michael S. Jennis ◽  
Joyce L. Peabody

Continuous monitoring of oxygenation in sick newborns is vitally important. However, transcutaneous Po2 measurements have a number of limiations. Therefore, we report the use of the pulse oximeter for arterial oxygen saturation (Sao2) determination in 26 infants (birth weights 725 to 4,000 g, gestational ages 24 to 40 weeks, and postnatal ages one to 49 days). Fetal hemoglobin determinations were made on all infants and were repeated following transfusion. Sao2, readings from the pulse oximeter were compared with the Sao2 measured in vitro on simultaneously obtained arterial blood samples. The linear regression equation for 177 paired measurements was: y = 0.7x + 27.2; r = .9. However, the differences between measured Sao2 and the pulse oximeter Sao2 were significantly greater in samples with > 50% fetal hemoglobin when compared with samples with < 25% fetal hemoglobin (P < .001). The pulse oximeter was easy to use, recorded trends in oxygenation instantaneously, and was not associated with skin injury. We conclude that pulse oximetry is a reliable technique for the continuous, noninvasive monitoring of oxygenation in newborn infants.


PEDIATRICS ◽  
1978 ◽  
Vol 62 (3) ◽  
pp. 299-303
Author(s):  
Lawrence D. Lilien ◽  
Tsu F. Yeh ◽  
Gertrude M. Novak ◽  
Norman M. Jacobs

Nine infants with early-onset Haemophilus sepsis were seen between January 1973 and July 1977. Of the five isolated strains that were typed, only one was type B. All infants had respiratory distress, metabolic acidosis, and large alveolar-arterial oxygen tension difference gradients. Eight infants weighed less than 1,500 gm and died; one infant weighed 1,701 gm and survived. Roentgenograms in six of eight showed hyaline membrane disease. Pulmonary pathologic specimens in eight infants revealed hyaline membranes in six and polymorphonuclear leukocytes in the alveolar spaces in four. In two infants, small Gram-negative bacilli were noted within proteinaceous exudates in alveolar ducts. The route and time of infection in these infants with early-onset Haemophilus sepsis are unclear. However, the possibility that the infection occurs before birth and that these infants represent septically aborted prematures is suggested by the high incidence of prematurity in infants with early-onset Haemophilus sepsis and early detection of bacteremia in three infants.


PEDIATRICS ◽  
1975 ◽  
Vol 55 (2) ◽  
pp. 232-235
Author(s):  
Gosta Rooth

Attention is called in this brief review article to the development and clinical uses of a new technique for monitoring blood oxygen tensions in newborn infants. This technique uses an electrode recently developed by Huch et al. in Germany to measure arterial oxygen tensions directly through the skin. This device allows for continuous monitoring with a non-invasive technique. The method is now in use in European hospitals. Clinical experiences are cited to document its usefulness.


PEDIATRICS ◽  
1976 ◽  
Vol 57 (2) ◽  
pp. 244-250
Author(s):  
M. Conway ◽  
G. M. Durbin ◽  
D. Ingram ◽  
N. McIntosh ◽  
D. Parker ◽  
...  

An oxygen electrode mounted in the tip of an umbilical artery catheter was used in 36 newborn infants with severe respiratory illnesses, 28 of whom survived. Thirty-seven electrodes were used. The median age at insertion was 4 hours (range, 30 minutes to 122 hours). Three electrodes failed to work and they were removed or replaced, and two could not be properly evaluated. Thirty-two electrodes functioned satisfactorily for 10 to 190 hours (mean, 75 hours) after a one-point calibration against blood sampled through the catheter. Twenty-two did not need recalibrating before they were removed after 10 to 190 hours (mean, 88 hours). Four of the remaining ten electrodes were recalibrated once after 33 to 97 hours and then functioned until removed 15 to 55 hours later. The other six electrodes failed after 32 to 105 hours (mean, 49 hours). Complications were few. A total of 356 arterial blood samples, obtained after the initial calibration and before any recalibration was necessary, gave a correlation coefficient of 0.93 (P < .0001) against an independent system for measuring arterial oxygen tension (Pao2) (Radiometer Type E.5046 oxygen electrode). We conclude that the catheter-tip electrode is a safe and reliable instrument for continuously recording Pao2 in newborn infants which much simplifies the management of serious respiratory illnesses.


Sign in / Sign up

Export Citation Format

Share Document