Development and Validation of a Simple RP-HPLC Method for Simultaneous Estimation of Three Therapeutically Active Compounds in a Polyherbal Formulation: Habb-e-Irqun-Nisa

Planta Medica ◽  
2013 ◽  
Vol 79 (05) ◽  
Author(s):  
A Ali ◽  
MA Khan ◽  
H Kabir ◽  
S Ahmad ◽  
MZ Abdin
INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (09) ◽  
pp. 43-54
Author(s):  
K Vijaya Sri ◽  
M. Madhuri ◽  
V. Anusha ◽  
V.R.K. Siresha ◽  

The present research work illustrates the development and validation of RP HPLC method for simultaneous estimation of tenofovir disproxil fumarate, emtricitabine and rilpivirine hydrochloride in bulk and formulated in a pharmaceutical dosage form as a nanosupension. Antiretroviral drug treatment is the primary line of therapy for treating HIV. The multicomponent system formulated as a nanosuspension evidenced increased hydrophilicity, potency and decreased side effects. The separation was carried out by using efficient BDS hypersil C18 HPLC column with empower software. Combination method of Precipitation—ultrasonic homogenization was used for the preparation of the nanosuspension. The mobile phase used was methanol, water, acetonitrile (80:13.4:6.6) v/v and flow rate 1mL /min. The developed method was thus validated as per ICH guidelines for various parameters whose results advocated the reliability of the method. The results for parameters viz. retention times of tenofovir disproxil fumarate, emtricitabine and rilpivirine were 3.09 min, 2.78 min and 3.68 min, linearity range was between 7.5-90, 5-60, 0.625-7.5µg/mL, respectively. Thus the new RP-HPLC method is optimum, reliable and can be used for the simultaneous estimation of tenofovir disproxil fumarate, emtricitabine and rilpivirine hydrochloride.


2021 ◽  
Vol 23 (06) ◽  
pp. 992-1000
Author(s):  
Sneha S. Ghule ◽  
◽  
Ashpak M. Tamboli ◽  
Snehal D. Patil ◽  
◽  
...  

A reverse-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of Pyridoxamine dihydrochloride and Acetylcysteine in the marketed formulation is developed. Chromatography carried out at 30oc temperature on Agilent Zorbax Bonus-RP (250 x 4.6 mm, 5 µ) coloum. Coloum using a mobile phase 0.1% trifluroacetic acid in water: acetonitrile (80:20v/v) with flow rate 1ml/min (DAD scan at 210nm). Validation parameters such as system suitability, linearity, precision, accuracy are considered as reported International Conference on Harmonization guidelines. The retention times for Pyridoxamine dihydrochloride and Acetylcysteine are 2 min and 3.4 min. The linearity range for Pyridoxamine dihydrochloride and Acetylcysteine is 30-70 µg/ml and 180-420 µg/ml. The %RSD for accuracy was found to be less than 2%. Hence the proposed method was found to be accurate, precise, reproducible, and specific and can be used for simultaneous analysis of these drugs in tablet formulation.


2020 ◽  
Vol 12 (3) ◽  
pp. 155-165
Author(s):  
Pooja Eknathji Waware ◽  
Anuja Dattatriayji Jolhe ◽  
Swati Rajendra Lilhare ◽  
Prasad Prakash Jumade ◽  
Dharmendra Ramgopalji Mundhada