scholarly journals Volar Central Portal in Wrist Arthroscopy

2016 ◽  
Vol 05 (01) ◽  
pp. 080-090 ◽  
Author(s):  
M. Ocampos ◽  
M. Cerro ◽  
R. Larrainzar-Garijo ◽  
T. Vázquez ◽  
F. Corella
2020 ◽  
Vol 16 (3) ◽  
pp. 170-177
Author(s):  
Wesley N. Sivak ◽  
Joseph E. Imbriglia

Wrist pain is a common patient complaint with a myriad of clinical conditions that can explain the underlying cause. Short of wrist arthroscopy, no technique other than formal wrist arthrotomy exists for direct examination of the hyaline cartilage coating the articular surfaces of the carpal bones. Magnetic resonance imaging (MRI) has been proven accurate in evaluating joint surfaces of large joints such as the shoulder, hip, and knee with articular cartilage surface thickness is in excess of 1 mm. However, in the carpus the thickness of the cartilage and the contours present have precluded accurate imaging. Advances in MRI technology over the last several decades are now making imaging of small joint surfaces, such as the carpus, an area worth revisiting. Herein we provide a review of these efforts with a specific focus on the evaluation of the wrist.


Author(s):  
Francisco J. Lucas ◽  
Vicente Carratalá ◽  
Ignacio Miranda ◽  
Cristobal Martinez-Andrade

Abstract Background Advances in wrist arthroscopy and the emergence of novel surgical techniques have created a need for new portals to the wrist. The aim of this study was to define and verify the safety of the volar distal radioulnar (VDRU) portal. Description of the Technique The VDRU portal is located ∼5 to 10 mm proximal to the proximal wrist crease, just on the ulnar edge of flexor carpi ulnaris tendon and radial to the dorsal cutaneous branch of the ulnar nerve. The ulnar styloid marks the distal point of the portal. Methods An anatomical study was performed on 12 upper extremity specimens of 6 human cadavers. Iatrogenic injuries of neurovascular structures potentially at risk were assessed, and the distance from the portal to these structures was measured. Results No iatrogenic injuries of the structures at risk occurred. Mean distances from the VDRU portal to the ulnar neurovascular bundle, the radial branch of the dorsal sensory branches of the ulnar nerve (DSBUN), and the ulnar branch of the DSBUN were 9.29 ± 0.26 mm, 8.08 ± 0.25 mm, and 10.58 ± 0.23 mm, respectively. There were no differences between left and right wrists. The distances from the VDRU portal to the ulnar neurovascular bundle and the ulnar branch of the DSBUN were significantly shorter in women; this distance was not less than 7 mm in any case. Conclusions The VDRU portal is safe, reproducible, and facilitates the implementation of various techniques related to triangular fibrocartilage complex pathology.


1987 ◽  
Vol 6 (3) ◽  
pp. 551-556 ◽  
Author(s):  
Susan M. Craig
Keyword(s):  

Hand Clinics ◽  
1999 ◽  
Vol 15 (3) ◽  
pp. 495-499 ◽  
Author(s):  
Daniel J. Nagle
Keyword(s):  

2014 ◽  
Vol 33 (2) ◽  
pp. 100-105 ◽  
Author(s):  
M.C. Obdeijn ◽  
J.V. Alewijnse ◽  
C. Mathoulin ◽  
P. Liverneaux ◽  
G.J.M. Tuijthof ◽  
...  

1998 ◽  
Vol 6 (1) ◽  
pp. 42-51 ◽  
Author(s):  
Kenji C. Miyasaka ◽  
Melvin P. Rosenwasser
Keyword(s):  

2021 ◽  
pp. 175319342110308
Author(s):  
Toshiyasu Nakamura ◽  
Pak Cheong Ho ◽  
Andrea Atzei ◽  
Fernando Corella ◽  
Jan-Ragnar Haugstvedt

Recent technical and technological developments in wrist arthroscopic surgery allow for advanced treatments of difficult wrist disorders. In this review, world leaders of wrist arthroscopy describe bone graft for scaphoid nonunion, transosseous repair for triangular fibrocartilage fovea avulsion, palmaris longus reconstruction of the triangular fibrocartilage, and arthroscopic reconstruction of the scapholunate and lunotriquetral ligaments.


2016 ◽  
Vol 41 (5) ◽  
pp. 516-520 ◽  
Author(s):  
K. Kasapinova ◽  
V. Kamiloski

Our purpose was to determine the correlation of initial radiographic parameters of a distal radius fracture with an injury of the triangular fibrocartilage complex. In a prospective study, 85 patients with surgically treated distal radius fractures were included. Wrist arthroscopy was used to identify and classify triangular fibrocartilage complex lesions. The initial radial length and angulation, dorsal angulation, ulnar variance and distal radioulnar distance were measured. Wrist arthroscopy identified a triangular fibrocartilage complex lesion in 45 patients. Statistical analysis did not identify a correlation with any single radiographic parameter of the distal radius fractures with the associated triangular fibrocartilage complex injuries. The initial radiograph of a distal radius fracture does not predict a triangular fibrocartilage complex injury. Level of evidence: III


Sign in / Sign up

Export Citation Format

Share Document