Comparison of Acorn and Fluted Reamers on Tibial Tunnel Outer Aperture Dimensions in Anterior Cruciate Ligament Reconstruction

Author(s):  
Adam D. Gerrard ◽  
Chris M. Jump ◽  
Paul Sutton ◽  
Charalambos P. Charalambous

AbstractThe aim of this study was to determine if the type of reamer used in tibial tunnel creation during anterior cruciate ligament (ACL) reconstruction influences the dimensions of the tunnel's outer aperture. Tibial tunnels were created in tibial saw bones by reaming over a guidewire using an 8 mm acorn or fluted reamer in an antegrade manner. Reaming was aimed either in line with the guidewire, or with 10-degree inferior/superior deviation in relation to the wire. The shape and size of the outer aperture of the tibial tunnel were compared between the two reamers. When using the acorn reamer, a 10-degree deviation in relation to the guidewire resulted in minimal change in outer aperture length (mean 13.6 vs. 15.6 mm, p = 0.11) and width (11.6 vs. 11.1 mm, p = 0.51). However, when using the fluted reamer, although the aperture width showed no substantial change with reamer/guidewire deviation (11.4 vs. 11.2 mm, p = 0.71), the mean length almost doubled (14.7 vs. 28.1 mm, p = 0.002). The use of a fluted reamer when reaming the tibial tunnel creates a distal aperture which is inconsistently sized, larger, and of oblong shape compared with an acorn-shaped reamer. This should be taken in consideration when using a fluted reamer for creating the tibial tunnel in ACL reconstruction.

2016 ◽  
Vol 22 (5) ◽  
pp. 368-373 ◽  
Author(s):  
Luiz Gabriel Betoni Guglielmetti ◽  
Ricardo de Paula Leite Cury ◽  
Victor Marques de Oliveira ◽  
Osmar Pedro Arbix de Camargo ◽  
Fabrício Roberto Severino ◽  
...  

Abstract Introduction: Although the results of anterior cruciate ligament (ACL) reconstruction are well documented in many studies, with good to excellent outcomes in most cases, some issues like tunnel positioning are still discussed and studied. Objective: To compare the objective and subjective clinical outcomes of ACL reconstruction using the transtibial and anteromedial portal techniques. Methods: Prospective randomized study of 80 patients undergoing anterior cruciate ligament reconstruction by the same surgeon, with 40 patients operated by the transtibial technique and 40 by anteromedial portal technique. The patients, 34 in the transtibial group and 37 in the anteromedial portal group (nine dropouts), were reassessed during a 2-year follow-up period. The clinical assessment consisted of physical examination, KT-1000TM evaluation, Lysholm score, and objective and subjective International Knee Documentation Committee - IKDC scores. Results: Regarding the Lachman and pivot shift tests, we observed more cases of instability in the transtibial group, but with no statistical significance (p=0.300 and p=0.634, respectively). Regarding the anterior drawer test, the groups presented similar results (p=0.977). Regarding KT-1000TM evaluation, the mean results were 1.44 for the transtibial group and 1.23 for the anteromedial portal group, with no statistical significance (p=0.548). We separated the objective IKDC scores into two groups: Group 1, IKDC A, and Group 2, IKDC B, C, or D, with no statistical significance (p=0.208). Concerning the Lysholm score, the transtibial group had a mean score of 91.32, and the anteromedial portal group had a mean score of 92.81. The mean subjective IKDC scores were 90.65 for the transtibial group and 92.65 for the anteromedial portal group. Three re-ruptures were encountered in the transtibial group and three in the anteromedial portal group. Conclusions: There were no significant differences in the subjective and objective clinical assessments among patients submitted to anterior cruciate ligament reconstruction using the transtibial or anteromedial portal techniques.


2021 ◽  
Vol 33 (1) ◽  
Author(s):  
Ravi Gupta ◽  
Sandeep Singh ◽  
Anil Kapoor ◽  
Ashwani soni ◽  
Ravinder Kaur ◽  
...  

Abstract Background Preservation of hamstring tendon insertion at the time of anterior cruciate ligament (ACL) reconstruction is a well-known technique; however, its effect on graft integration is not well studied. The present study was conducted to study the graft integration inside the tibial and femoral tunnels, respectively, after ACL reconstruction using hamstring tendon graft with preserved insertion. Methods Twenty-five professional athletes who underwent ACL reconstruction using hamstring tendon graft with preserved tibia insertion were enrolled in the study. Functional outcomes were checked at final follow-up using Lysholm score and Tegner activity scale. Magnetic resonance imaging (MRI) was done at 8 months and 14 months follow-up to study the graft tunnel integration of the ACL graft at both tibial and femoral tunnels. Results The mean Fibrous interzone (FI) score (tibial tunnel) decreased from 2.61 (1–5) at 8 months to 2.04 (1–4) at 14 months follow-up (p = 0.02). The mean FI score (femoral side) decreased from 3.04 (2–5) at 8 months to 2.57 (2–4) at 14 months (p = 0.02). Conclusions Graft integration occurs early in the tibial tunnel as compared with the femur tunnel with preserved insertion hamstring tendon autograft. Trial registration CTRI/2019/07/020320 [registered on 22/07/2019]; http://www.ctri.nic.in/Clinicaltrials/pdf_generate.php?trialid=33884&EncHid=&modid=&compid=%27,%2733884det%27


2020 ◽  
Vol 8 (11) ◽  
pp. 232596712096009
Author(s):  
Etienne Cavaignac ◽  
Timothée Mesnier ◽  
Vincent Marot ◽  
Andrea Fernandez ◽  
Marie Faruch ◽  
...  

Background: It has been shown that adding lateral extra-articular tenodesis (LET) to standard anterior cruciate ligament (ACL) reconstruction significantly decreases the loads on the ACL composite graft. To date, the possible effect of LET on ACL graft incorporation is not known. Purpose: To compare the incorporation in tibial bone tunnels of a standard quadrupled semitendinosus (ST4) graft to an ST4 graft plus LET at 1 year postoperatively using magnetic resonance imaging (MRI). Study Design: Cohort study; Level of evidence, 3. Methods: A total of 62 patients who underwent ACL reconstruction were enrolled prospectively: 31 received an ST4 graft, and 31 received an ST4 graft plus LET. Graft incorporation was evaluated with MRI at the 1-year follow-up visit. The following parameters were evaluated: signal-to-noise quotient (SNQ), tibial tunnel widening, graft healing, and graft maturity according to the Howell scale. The primary endpoint was the SNQ of the ST4 graft at 1 year postoperatively; this parameter was adjusted because of unequal baseline characteristics between groups. Clinical and functional outcomes as well as incorporation of the graft were analyzed as secondary endpoints. Results: The mean adjusted SNQ was 0.5 ± 2.1 (95% CI, 0.4-4.6) in the ST4 + LET group and 5.9 ± 3.7 (95% CI, 4.7-7.0) in the ST4 group ( P = .0297). The mean tibial tunnel widening was 73.7% ± 42.2% in the ST4 + LET group versus 77.5% ± 46.7% in the ST4 group ( P = .5685). Howell grade I, indicative of better graft maturity, was statistically more frequent in the ST4 + LET group ( P = .0379). No statistically significant difference was seen between groups in terms of graft healing ( P = .1663). The Lysholm score was statistically higher in the ST4 + LET group ( P = .0058). No significant differences were found between groups in terms of the International Knee Documentation Committee subjective score ( P = .2683) or Tegner score ( P = .7428). The mean SNQ of the LET graft at the 1-year follow-up visit was 2.6 ± 4.9. Conclusion: At 1 year postoperatively, the MRI appearance of ACL grafts showed generally better incorporation and maturation when combined with LET.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Chao-Hua Fang ◽  
Ming Li ◽  
Yun-Feng Zhang ◽  
Hua Liu

Abstract Background The interference screw is the most popular device that fixes the graft for anterior cruciate ligament reconstruction, reducing the incidence of windshield effect and bungee effect. For the screw, either metallic, “bioresorbable,” or polyetheretherketone (PEEK) material is available. PEEK is popular and extensively used due to its stability, biocompatibility, radiolucency, and elastic modulus. Rare relevant complications were reported, but here, we report two cases of extra-articular migrations of PEEK interference screw from the tibial tunnel after anterior cruciate reconstruction. Case report An 18-year-old boy and a 56-year-old woman underwent anterior cruciate ligament reconstruction using a PEEK interference screw to fix the graft in the tibial tunnel. They suffered from screw extrusion from the tibial tunnel after 40 days and six months, respectively, with an incision rupture or palpable subcutaneous mass. They underwent a second operation and recovered well. Conclusions The exact incidence of extra-articular migrations of PEEK interference screws is unknown, but it seems to be quite low; despite this and its uncertain cause, the negative effects caused by the PEEK material need to be considered.


2012 ◽  
Vol 18 (3) ◽  
pp. 111-115
Author(s):  
O.M. Russu ◽  
I. Gergely ◽  
Ancuța Zazgyva ◽  
I. Moldovan ◽  
T.S. Pop

Abstract Evaluating the early clinical results of anterior cruciate ligament reconstruction using hamstrings autograft, with interference screw on the tibial side (biocomposite interference screw, ConMed-Linvatec) and continuous closed loop fixation on the femoral side (XO-Button, ConMed-Linvatec), with and without intra-articular injection of autologous conditioned plasma (ACP). Our study included 21 patients with chronic anterior cruciate ligament (ACL) ruptures for whom we performed ACL reconstruction with a hamstrings autograft. The mean age was 34 years (range, 25 to 42), 16 patients were men and 5 were women. In 10 cases we performed an intraarticular infiltration of ACP at the end of the surgical intervention. Final evaluation was performed at the end of the 6th postoperative month using the Lysholm scoring system, Tegner activity scale and objective assessment with the RolimeterTM 50A. The Lysholm score was excellent in all cases at 6 months postoperatively, with a mean Lysholm score of 90 for patients without ACP and 91.09 for patients that received ACP; the mean Tegner activity score was also similar pre- and postoperatively for the two groups (from 3.5 and 3.63 for the group without ACP and the group with ACP to 5.6 and 5.72 respectively). Joint laxity measurement was similar for both groups. We found no graft ruptures. We found similar results after ACL reconstruction with and without intra-articular injection of PRP, but further studies are necessary to determine the exact role of these substances in speeding up the recovery process in these cases.


2003 ◽  
Vol 31 (2) ◽  
pp. 282-288 ◽  
Author(s):  
Hironori Otsuka ◽  
Yasuyuki Ishibashi ◽  
Eiichi Tsuda ◽  
Kazuhiro Sasaki ◽  
Satoshi Toh

Background: Anatomic fixation of the graft in anterior cruciate ligament reconstruction has improved stability of the reconstructed knee joint in experimental studies. Hypothesis: Anatomic fixation of the bone-patellar tendon-bone autograft will reduce tunnel enlargement and improve clinical results. Study Design: Prospective cohort study. Methods: Sixty patients were randomly divided into three groups: a nonanatomic fixation group (traditional single-incision reconstruction), an anatomic fixation group (reconstruction in which a bone plug was grafted into the tibial tunnel), and an anatomic fixation group with all-inside reconstruction. Stability of the knee joint was examined with a KT-1000 arthrometer at 2, 4, 6, 12, and 24 months after surgery. At 12 months, anteroposterior and lateral radiographs were made to assess tunnel enlargement. Results: Although the magnitude of tibial displacement gradually increased after reconstruction in all three groups, the anatomic fixation group had significantly better stability than the groups undergoing nonanatomic fixation or all-inside anatomic fixation at 4 and 6 months after anterior cruciate ligament reconstruction. However, there was no significant difference between the three groups at 24 months. Regarding the tibial tunnel, residual rates and enlargement of tunnels were different between the reconstruction techniques. The nonanatomic reconstruction group had significantly greater tunnel enlargement. Conclusion: Anatomic fixation of the graft decreased the tunnel enlargement but had no effect on knee stability at 2-year follow-up.


2021 ◽  
pp. 036354652110273
Author(s):  
Joshua S. Everhart ◽  
Sercan Yalcin ◽  
Kurt P. Spindler

Background: Several long-term (≥20 years) follow-up studies after anterior cruciate ligament (ACL) reconstruction have been published in recent years, allowing for a systematic evaluation of outcomes. Purpose: To summarize outcomes at ≥20 years after ACL reconstruction and identify patient and surgical factors that affect these results. Study Design: Systematic review; Level of evidence, 4. Methods: Prospective studies of primary ACL reconstructions with hamstring or bone–patellar tendon—bone (BTB) autograft via an arthroscopic or a mini-open technique and with a mean follow-up of ≥20 years were identified. When possible, the mean scores for each outcome measure were calculated. Factors identified in individual studies as predictive of outcomes were described. Results: Five studies met the inclusion and exclusion criteria with a total of 2012 patients. The pooled mean follow-up for patient-reported outcome measures was 44.2% (range, 29.6%-92.7%) and in-person evaluation was 33.2% (range, 29.6%-48.9%). Four studies (n = 584) reported graft tears at a mean rate of 11.8% (range, 2%-18.5%) and 4 studies (n = 773) reported a contralateral ACL injury rate of 12.2% (range, 5.8%-30%). Repeat non-ACL arthroscopic surgery (4 studies; n = 177) to the ipsilateral knee occurred in 10.4% (range, 9.5%-18.3%) and knee arthroplasty (1 study; n = 217) in 5%. The pooled mean of the International Knee Documentation Committee subjective knee function (IKDC) score was 79.1 (SD, 21.8 [3 studies; n = 644]). In 2 studies (n?= 221), 57.5% of patients continued to participate in strenuous activities. The IKDC-objective score was normal or nearly normal in 82.3% (n = 496; 3 studies), with low rates of clinically significant residual laxity. Moderate-severe radiographic osteoarthritis (OA) (IKDC grade C or D) was present in 25.9% of patients (n = 605; 3 studies). Medial meniscectomy is associated with increased risk of radiographic OA. Radiographic OA severity is associated with worse patient-reported knee function, but the association with knee pain is unclear. Conclusion: Currently available prospective evidence for ACL reconstruction with hamstring or BTB autograft provides several insights into outcomes at 20 years. The rates of follow-up at 20 years range from 30% to 93%. IKDC-objective scores were normal or nearly normal in 82% and the mean IKDC-subjective score was 79 points.


Author(s):  
Ali Aneizi ◽  
Elizabeth Friedmann ◽  
Leah E. Henry ◽  
Gregory Perraut ◽  
Patrick M. J. Sajak ◽  
...  

AbstractAnterior cruciate ligament reconstruction (ACLR) is one of the most commonly performed outpatient orthopaedic procedures, yet there is little data about perioperative opioid prescribing practices. The purposes of this study were to quantify the perioperative opioid prescriptions filled by patients who underwent ACLR and to identify factors associated with greater postoperative opioid use. Patients who underwent ACLR at a single institution between June 2015 and May 2017 were studied using a regional prescription monitoring database to identify all preoperative and postoperative outpatient opioid prescriptions up to 2 years postoperatively. The number of morphine milligram equivalents of each opioid was calculated to determine total morphine milligram equivalents (TMEs) filled preoperatively, at discharge, and refilled postoperatively. Patients who refilled an opioid prescription postoperatively were compared with those who did not. Ninety-nine of 269 (36.8%) total patients refilled an opioid prescription postoperatively. Thirty-three patients (12.3%) required a refill after 2 weeks postoperatively, and no patients refilled after 21 months postoperatively. Fifty-seven patients (21%) received an opioid prescription in the 2 years following surgery that was unrelated to their ACL reconstruction. Increased age, higher body mass index (BMI), government insurance, current or prior tobacco use history, preoperative opioid use, and greater number of medical comorbidities were significantly associated with refilling a prescription opioid. Higher BMI and government insurance were independent predictors of refilling. Higher preoperative TMEs and surgeon were independent predictor of greater refill TMEs. In the opioid-naïve subgroup of 177 patients, only higher BMI was a predictor of refilling, and only greater comorbidities was a predictor of greater refill TMEs. The results demonstrate that preoperative opioid use was associated with postoperative opioid refills and higher refill TMEs in a dose-dependent fashion. A higher percentage of patients received an opioid prescription for reasons unrelated to the ACL reconstruction than refilled a prescription after the first 2 weeks postoperatively.


Sign in / Sign up

Export Citation Format

Share Document