scholarly journals TRANSTIBIAL VERSUS ANTEROMEDIAL PORTAL TECHNIQUES IN ACL RECONSTRUCTION

2016 ◽  
Vol 22 (5) ◽  
pp. 368-373 ◽  
Author(s):  
Luiz Gabriel Betoni Guglielmetti ◽  
Ricardo de Paula Leite Cury ◽  
Victor Marques de Oliveira ◽  
Osmar Pedro Arbix de Camargo ◽  
Fabrício Roberto Severino ◽  
...  

Abstract Introduction: Although the results of anterior cruciate ligament (ACL) reconstruction are well documented in many studies, with good to excellent outcomes in most cases, some issues like tunnel positioning are still discussed and studied. Objective: To compare the objective and subjective clinical outcomes of ACL reconstruction using the transtibial and anteromedial portal techniques. Methods: Prospective randomized study of 80 patients undergoing anterior cruciate ligament reconstruction by the same surgeon, with 40 patients operated by the transtibial technique and 40 by anteromedial portal technique. The patients, 34 in the transtibial group and 37 in the anteromedial portal group (nine dropouts), were reassessed during a 2-year follow-up period. The clinical assessment consisted of physical examination, KT-1000TM evaluation, Lysholm score, and objective and subjective International Knee Documentation Committee - IKDC scores. Results: Regarding the Lachman and pivot shift tests, we observed more cases of instability in the transtibial group, but with no statistical significance (p=0.300 and p=0.634, respectively). Regarding the anterior drawer test, the groups presented similar results (p=0.977). Regarding KT-1000TM evaluation, the mean results were 1.44 for the transtibial group and 1.23 for the anteromedial portal group, with no statistical significance (p=0.548). We separated the objective IKDC scores into two groups: Group 1, IKDC A, and Group 2, IKDC B, C, or D, with no statistical significance (p=0.208). Concerning the Lysholm score, the transtibial group had a mean score of 91.32, and the anteromedial portal group had a mean score of 92.81. The mean subjective IKDC scores were 90.65 for the transtibial group and 92.65 for the anteromedial portal group. Three re-ruptures were encountered in the transtibial group and three in the anteromedial portal group. Conclusions: There were no significant differences in the subjective and objective clinical assessments among patients submitted to anterior cruciate ligament reconstruction using the transtibial or anteromedial portal techniques.

2012 ◽  
Vol 18 (3) ◽  
pp. 111-115
Author(s):  
O.M. Russu ◽  
I. Gergely ◽  
Ancuța Zazgyva ◽  
I. Moldovan ◽  
T.S. Pop

Abstract Evaluating the early clinical results of anterior cruciate ligament reconstruction using hamstrings autograft, with interference screw on the tibial side (biocomposite interference screw, ConMed-Linvatec) and continuous closed loop fixation on the femoral side (XO-Button, ConMed-Linvatec), with and without intra-articular injection of autologous conditioned plasma (ACP). Our study included 21 patients with chronic anterior cruciate ligament (ACL) ruptures for whom we performed ACL reconstruction with a hamstrings autograft. The mean age was 34 years (range, 25 to 42), 16 patients were men and 5 were women. In 10 cases we performed an intraarticular infiltration of ACP at the end of the surgical intervention. Final evaluation was performed at the end of the 6th postoperative month using the Lysholm scoring system, Tegner activity scale and objective assessment with the RolimeterTM 50A. The Lysholm score was excellent in all cases at 6 months postoperatively, with a mean Lysholm score of 90 for patients without ACP and 91.09 for patients that received ACP; the mean Tegner activity score was also similar pre- and postoperatively for the two groups (from 3.5 and 3.63 for the group without ACP and the group with ACP to 5.6 and 5.72 respectively). Joint laxity measurement was similar for both groups. We found no graft ruptures. We found similar results after ACL reconstruction with and without intra-articular injection of PRP, but further studies are necessary to determine the exact role of these substances in speeding up the recovery process in these cases.


2020 ◽  
Vol 22 (3) ◽  
pp. 181-185
Author(s):  
Ramy Said Assaad Ahmed Mohamed ◽  
Mohamed Hossam El-Din El-Shafie ◽  
Mohamed Ahmed El-Sheikh

Background. Anterior cruciate ligament (ACL) reconstruction has remained the gold standard for ACL injuries, especially for young individuals and athletes exposed to high level sporting activities aiming to return to their preinjury level of activity. Cortical suspensory femoral fixation is commonly performed for graft fixation to the femur in anterior cruciate ligament reconstruction using hamstring tendons. The aim of this study was to compare the clinical results of using fixed and adjustable loop cortical suspension devices in arthroscopic ACL reconstruction using the Lysholm Knee Scoring Scale after 12 months postoperatively. Material and methods. This study included a total of sixty patients who underwent transportal arthroscopic ACL reconstruction using a hamstring tendon autograft from November 2016 to December 2017. For femoral graft fixation, a fixed-length loop device was used in 30 patients (fixed-loop group) and an adjustable-length loop device was used in 30 patients (adjustable-loop group) randomly.For tibial graft fixation, interference screw was used for all patients. Results. The present study shows that there was no statistically significant difference between the two groups regarding the Lysholm score with highly statistically significant difference between preoperative and postoperative Lysholm score in each group separately. Conclusion. Both fixed loop and adjustable loop devices in ACL reconstruction provided good clinical outcomes but without significant statistical difference between both groups from the clinical point of view postoperatively using the Lysholm score.


Author(s):  
Ali Aneizi ◽  
Elizabeth Friedmann ◽  
Leah E. Henry ◽  
Gregory Perraut ◽  
Patrick M. J. Sajak ◽  
...  

AbstractAnterior cruciate ligament reconstruction (ACLR) is one of the most commonly performed outpatient orthopaedic procedures, yet there is little data about perioperative opioid prescribing practices. The purposes of this study were to quantify the perioperative opioid prescriptions filled by patients who underwent ACLR and to identify factors associated with greater postoperative opioid use. Patients who underwent ACLR at a single institution between June 2015 and May 2017 were studied using a regional prescription monitoring database to identify all preoperative and postoperative outpatient opioid prescriptions up to 2 years postoperatively. The number of morphine milligram equivalents of each opioid was calculated to determine total morphine milligram equivalents (TMEs) filled preoperatively, at discharge, and refilled postoperatively. Patients who refilled an opioid prescription postoperatively were compared with those who did not. Ninety-nine of 269 (36.8%) total patients refilled an opioid prescription postoperatively. Thirty-three patients (12.3%) required a refill after 2 weeks postoperatively, and no patients refilled after 21 months postoperatively. Fifty-seven patients (21%) received an opioid prescription in the 2 years following surgery that was unrelated to their ACL reconstruction. Increased age, higher body mass index (BMI), government insurance, current or prior tobacco use history, preoperative opioid use, and greater number of medical comorbidities were significantly associated with refilling a prescription opioid. Higher BMI and government insurance were independent predictors of refilling. Higher preoperative TMEs and surgeon were independent predictor of greater refill TMEs. In the opioid-naïve subgroup of 177 patients, only higher BMI was a predictor of refilling, and only greater comorbidities was a predictor of greater refill TMEs. The results demonstrate that preoperative opioid use was associated with postoperative opioid refills and higher refill TMEs in a dose-dependent fashion. A higher percentage of patients received an opioid prescription for reasons unrelated to the ACL reconstruction than refilled a prescription after the first 2 weeks postoperatively.


2018 ◽  
Vol 7 (5) ◽  
pp. 327-335 ◽  
Author(s):  
Y. Sato ◽  
R. Akagi ◽  
Y. Akatsu ◽  
Y. Matsuura ◽  
S. Takahashi ◽  
...  

Objectives To compare the effect of femoral bone tunnel configuration on tendon-bone healing in an anterior cruciate ligament (ACL) reconstruction animal model. Methods Anterior cruciate ligament reconstruction using the plantaris tendon as graft material was performed on both knees of 24 rabbits (48 knees) to mimic ACL reconstruction by two different suspensory fixation devices for graft fixation. For the adjustable fixation device model (Socket group; group S), a 5 mm deep socket was created in the lateral femoral condyle (LFC) of the right knee. For the fixed-loop model (Tunnel group; group T), a femoral tunnel penetrating the LFC was created in the left knee. Animals were sacrificed at four and eight weeks after surgery for histological evaluation and biomechanical testing. Results Histologically, both groups showed a mixture of direct and indirect healing patterns at four weeks, whereas only indirect healing patterns were observed in both groups at eight weeks. No significant histological differences were seen between the two groups at four and eight weeks in the roof zone (four weeks, S: mean 4.8 sd 1.7, T: mean 4.5 sd 0.5, p = 0.14; eight weeks, S: mean 5.8 sd 0.8, T: mean 4.8 sd 1.8, p = 0.88, Mann-Whitney U test) or side zone (four weeks, S: mean 5.0 sd 1.2, T: mean 4.8 sd 0.4, p = 0.43; eight weeks, S: mean 5.3 sd 0.8,T: mean 5.5 sd 0.8, p = 0.61, Mann-Whitney U test) . Similarly, no significant difference was seen in the maximum failure load between group S and group T at four (15.6 sd 9.0N and 13.1 sd 5.6N) or eight weeks (12.6 sd 3.6N and 17.1 sd 6.4N, respectively). Conclusion Regardless of bone tunnel configuration, tendon-bone healing after ACL reconstruction primarily occurred through indirect healing. No significant histological or mechanical differences were observed between adjustable and fixed-loop femoral cortical suspension methods. Cite this article: Y. Sato, R. Akagi, Y. Akatsu, Y. Matsuura, S. Takahashi, S. Yamaguchi, T. Enomoto, R. Nakagawa, H. Hoshi, T. Sasaki, S. Kimura, Y. Ogawa, A. Sadamasu, S. Ohtori, T. Sasho. The effect of femoral bone tunnel configuration on tendon-bone healing in an anterior cruciate ligament reconstruction: An animal study. Bone Joint Res 2018;7:327–335. DOI: 10.1302/2046-3758.75.BJR-2017-0238.R2.


2016 ◽  
Vol 1 (s2) ◽  
pp. 23-26
Author(s):  
Octav Russu ◽  
Tiberiu Bățagă ◽  
Andrei-Marian Feier ◽  
Radu Prejbeanu ◽  
Radu Fleaca ◽  
...  

Abstract Introduction: Anterior cruciate ligament (ACL) rupture is one of the most common lesions in knee traumatology; therefore the number of ACL reconstructions is increasing worldwide. Usually, an anteromedial (AM) accessory portal is required in anatomical positioning of the femoral tunnel, which is not absolutely necessary in this technique. Aim: Assessment of all-inside ACL reconstruction preliminary clinical results with adjustable loops and buttons on both femoral and tibial surfaces. Method: Our prospective study included 28 subjects (19 male, 9 female) with chronic ACL ruptures. The mean age of the study population was 27.72 ± 8.23 years. In all cases ACL reconstruction was carried out with the use of quadrupled semitendinosus auto-grafts with adjustable loops and buttons on the femoral and tibial surfaces and anatomic placement of both tunnels, using an outside-in technique, with flipcutters (Arthrex®). Clinical and radiological evaluations were carried out before surgery and at 3 and 6 months postoperatively, with the Lysholm scoring system, the Tegner activity scale and anterior-posterior and latero-lateral X-rays. Anterior knee laxity was measured in 25° of flexion using a portable arthrometer (RolimeterTM, Aircast®) and maximum manual force. Results: During the final follow-up, the Lysholm score was good and excellent in 27 cases, with a mean Lysholm score of 95.55 ± 4.63; all results were classified as good. The mean preoperative Tegner activity score was 3.46 ± 1.71 (range: 1-7), and the post-operative mean score was 5.75 ± 2.24 (range: 2-10). We found no graft ruptures. Preoperative knee laxity measurements showed a mean displacement of 11.5 ± 3.1 mm and side-to-side differences of 5.6 ± 3.5 mm, while the postoperative measurements at the last follow-up were 6.3 ± 1.54 mm and 2.65 ± 1.86 mm, respectively. Conclusion: Short-term clinical outcomes of all-inside ACL restoration with anatomic placement femoral and tibial tunnels seem to recommend this surgical option, with good subjective and objective results. Additional research will have to prove the long-term success.


Sign in / Sign up

Export Citation Format

Share Document