Low-Degree Tibial Slope Angle Prevents Component Overhang by Enlarging the Lateral Plateau Surface Area in Total Knee Arthroplasty

Author(s):  
Mehmet Emin Simsek ◽  
Mustafa Akkaya ◽  
Safa Gursoy ◽  
Özgür Kaya ◽  
Murat Bozkurt

AbstractThis study aimed to investigate whether overhang or underhang around the tibial component that occurs during the placement of tibial baseplates was affected by different slope angles of the tibial plateau and determine the changes in the lateral and medial plateau diameters while changing the slope angle in total knee arthroplasty. Three-dimensional tibia models were reconstructed using the computed tomography scans of 120 tibial dry bones. Tibial plateau slope cuts were performed with 9, 7, 5, 3, and 0 degrees of slope angles 2-mm below the subchondral bone in the deepest point of the medial plateau. Total, lateral, and medial tibial plateau areas and overhang/underhang rates were measured at each cut level. Digital implantations of the asymmetric and symmetric tibial baseplates were made on the tibial plateau with each slope angles. Following the implantations, the slope angle that prevents overhang or underhang at the bone border and the slope angle that has more surface area was identified. A significant increase was noted in the total tibial surface area, lateral plateau surface area, and lateral anteroposterior distance, whereas the slope cut angles were changed from 9 to 0 degrees in both gender groups. It was found that the amount of posteromedial underhang and posterolateral overhang increased in both the asymmetric and symmetric tibial baseplates when the slope angle was changed from 0 to 9 degrees. Although the mediolateral diameter did not change after the proximal tibia cuts at different slope angles, the surface area and anteroposterior diameter of the lateral plateau could change, leading to increased lateral plateau area. Although prosthesis designs are highly compatible with the tibial surface area, it should be noted that the component overhangs, especially beyond the posterolateral edge, it can be prevented by changing the slope cut angle in males and females.

2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Ye-Ran Li ◽  
Yu-Hang Gao ◽  
Chen Yang ◽  
Lu Ding ◽  
Xuebo Zhang ◽  
...  

Abstract Background Despite potential for improving patient outcomes, studies using three-dimensional measurements to quantify proximal tibial sclerotic bone and its effects on prosthesis stability after total knee arthroplasty (TKA) are lacking. Therefore, this study aimed to determine: (1) the distribution range of tibial sclerotic bone in patients with severe genu varum using three-dimensional measurements, (2) the effect of the proximal tibial sclerotic bone thickness on prosthesis stability according to finite-element modelling of TKA with kinematic alignment (KA), mechanical alignment (MA), and 3° valgus alignment, and (3) the effect of short extension stem augment utilization on prosthesis stability. Methods The sclerotic bone in the medial tibial plateau of 116 patients with severe genu varum was measured and classified according to its position and thickness. Based on these cases, finite-element models were established to simulate 3 different tibial cut alignments with 4 different thicknesses of the sclerotic bone to measure the stress distribution of the tibia and tibial prosthesis, the relative micromotion beneath the stem, and the influence of the short extension stem on stability. Results The distribution range of proximal tibial sclerotic bone was at the anteromedial tibial plateau. The models were divided into four types according to the thickness of the sclerotic bone: 15 mm, 10 mm, 5 mm, and 0 mm. The relative micromotion under maximum stress was smallest after MA with no sclerotic bone (3241 μm) and largest after KA with 15 mm sclerotic bone (4467 μm). Relative micromotion was largest with KA and smallest with MA in sclerotic models with the same thickness. Relative micromotion increased as thickness of the sclerotic bone increased with KA and MA (R = 0.937, P = 0.03 and R = 0.756, P = 0.07, respectively). Relative micromotion decreased with short extension stem augment in the KA model when there was proximal tibial sclerotic bone. Conclusions The influence of proximal tibial sclerotic bone on prosthesis’s stability is significant, especially with KA tibial cut. Tibial component’s short extension stem augment can improve stability.


Introduction: The aim of this work was to compare the posterior tibial slope of the tibial component after performing a total knee arthroplasty, as an intramedullary or extramedullary guide was used during the surgical technique, as well as comparing the range of mobility obtained according to the Instrumentation used. Material and methods: We conducted a descriptive, retrospective, observational study of a series of 57 patients operated in our Center during 2012 and 2013, with the same model of total knee arthroplasty (Sigma PS® DePuy), divided into two homogeneous groups in terms of age, sex, degree of osteoarthritis evolution, the first with patients operated by extramedullary guidance and the second by intramedullary guidance. A radiographic study was performed, measuring the posterior slope angle in the sagittal plane. The range of mobility achieved after arthroplasty and implant survival was studied. Results: Together, in both groups, measurements of the posterior slope angle were made, which was 4.35º preoperative average. In groups, the mean postoperative posterior fall angle was 4.04 ° in the patients who underwent an EM guide, while those who underwent an IM guide the mean was 1.76 °; the differences being statistically significant. The range of mobility in the ATRs operated by intramedullary guidance was 102.7º on average (range 80-125º), while in the group where the extramedullary guide was used, it was 104.3º (range 80-130º) no these differences being statistically significant. Regarding the survival of the implant, during the study period two cases of patients undergoing surgery for the replacement of prostheses were found, both of which belonged to the “Extramedullary guide” group. Conclusion: The posterior drop angle, for the same PS prosthesis model, was statistically different according to the guide used, being within the 3-7º range in the group where the extramedullary guide was used; but despite these differences, no impact on the range of mobility was observed. Currently, it is recommended to restore the patient's posterior tibial slope, and in cases with a slope greater than 10º use a PS ATR.


Author(s):  
J. Michael Johnson ◽  
Mohamed R. Mahfouz ◽  
Mehmet Rüştü Midillioğlu ◽  
Alexander J. Nedopil ◽  
Stephen M. Howell

2018 ◽  
Vol 32 (10) ◽  
pp. 989-994
Author(s):  
Yoshinori Inou ◽  
Tetsuya Tomita ◽  
Dai Kiyotomo ◽  
Hideki Yoshikawa ◽  
Kazuomi Sugamoto

AbstractIn this study, the effects of tibial bone cutting on the attachment area of the posterior cruciate ligament (PCL), including both the anterolateral bundle (ALB) and posteromedial bundle (PMB), in cruciate-retaining total knee arthroplasty (CR-TKA) were simulated using a three-dimensional (3D) model of the tibial reconstruction. A total of 40 knees with medial osteoarthritis in patients scheduled for TKA were evaluated. Following surface registration of 3D computed tomography (CT) and 3D magnetic resonance imaging (MRI) models of the tibia with the PCL, the area of PCL attachment was calculated. Tibial bone cutting in the 3D CT model was simulated at 8 and 10 mm distal to the center of the lateral articular surfaces of the tibia and with posterior tibial slope angles of 0, 7, and 10 degrees. The percentages of the ALB and PMB tibial attachment areas that remained after cutting at 8 mm were, respectively, 21.8 ± 19.7% and 86.3 ± 17.7% with 0 degrees, 9.5 ± 10.4% and 64.1 ± 23.6% with 7 degrees, and 8.1 ± 6.7% and 51 ± 25.3% with 10 degrees. These results suggest that only half of the PCL attachment area was left after the bone cut simulation. Complete preservation of the ALB and PMB attachment areas requires appropriate selection of surgical procedures and devices.


2021 ◽  
pp. 1-14
Author(s):  
Yuki Takahashi ◽  
Takashi Sato ◽  
Tomoharu Mochizuki ◽  
Satoshi Watanabe ◽  
Osamu Tanifuji ◽  
...  

BACKGROUND: After total knee arthroplasty (TKA), the femur tends to be located posteriorly under weight-bearing (WB) conditions, and a paradoxical femoral anterior motion occurs, leading to joint instability. OBJECTIVE: We aimed to clarify factors which affect the postoperative femoral anteroposterior position relative to the tibia under WB conditions (A-P position) in medial pivot (MP) TKA. METHODS: Among 126 knees (81 women) with primary TKA using MP prosthesis for varus osteoarthritic knees, 70 knees had cruciate-retaining inserts (CR) with the reduced conformity and 56 knees had cruciate-substituting inserts (CS) with the full conformity. Using the three-dimensional (3D) assessment system, the associations between the A-P position and the factors including pre- and postoperative lower extremity alignment, component positions, and posterior femoral condylar offset (PCO), were assessed regarding the type of inserts. RESULTS: Significant correlations were seen between the A-P position and posterior tibial slope (PTS), medial PCO, and lateral PCO. Regarding the difference between the two inserts, the PTS, medial PCO, and lateral PCO significantly correlated with the A-P position in the CR, but only the PTS correlated in the CS. CONCLUSIONS: The increased PTS and decreased PCO were the dominant factors for the A-P position in MP TKA.


Author(s):  
O-Sung Lee ◽  
Jangyun Lee ◽  
Myung Chul Lee ◽  
Hyuk-Soo Han

AbstractThe posterior tibial slope (PTS) is usually adjusted by less than 5 degrees, without considering its individual difference, during posterior cruciate-substituting (PS) total knee arthroplasty (TKA). The effect of these individual changes of PTS would be important because clinical results depending on postoperative PTS were reported conflictingly. We investigated the effect of the change in PTS on the postoperative range of motion (ROM) and clinical scores after PS TKA. We retrospectively reviewed 164 knees from 107 patients who underwent PS TKA with a 2-year follow-up. We analyzed the preoperative and postoperative PTS, ROM, visual analog scale pain scale, Western Ontario and McMaster University Index (WOMAC), Hospital for Special Surgery Knee Score, Knee Society Score, and Forgotten Joint Score (FJS). The association of the absolute change in PTS with ROM and clinical scores was analyzed using correlation analysis and multiple regression analysis. As a result, the mean PTS and mean ROM changed from 9.6 ±  3.4 and 120.1 ±  15.4 degrees preoperatively to 2.0 ±  1.3 and 128.4 ±  9.3 degrees postoperatively, and the mean PTS change was 7.6 ±  3.5 degrees. The PTS change had no statistically significant association with the postoperative ROM and clinical scoring systems, although it did have a weak positive correlation with WOMAC function, No 10 (difficulty in rising from sitting) (correlation coefficient = 0.342, p = 0.041), and moderate positive correlation with the FJS, No. 6 (awareness when climbing stairs) (correlation coefficient = 0.470, p = 0.001). The authors concluded that the amount of change in PTS did not affect the postoperative ROM and clinical scores, although proximal tibial resection with a constant target of PTS resulted in individually different changes in the PTS after PS TKA,


Author(s):  
Masanori Tsubosaka ◽  
Tomoyuki Kamenaga ◽  
Yuichi Kuroda ◽  
Koji Takayama ◽  
Shingo Hashimoto ◽  
...  

AbstractSeveral studies have reported better clinical outcomes following kinematically aligned total knee arthroplasty (KA-TKA) than mechanically aligned TKA. Consistent reproduction of a KA-TKA is aided by accurate tibial bone resections using computer navigation systems. This study compares an accelerometer-based portable navigation system with a conventional navigation system on tibial bone resection and clinical outcomes in KA-TKA. This study included 60 knees of patients who underwent primary KA-TKA between May 2015 and September 2017. They were randomly assigned to the OrthoPilot and iASSIST groups. A tibial bone cut was performed with 3 degree varus and 7 degree posterior slope in relation to the mechanical axis in all cases. The tibial component angle (TCA) and posterior slope angle (PSA) were evaluated by postoperative radiography, and those that deviated more than 2 degree were set as outliers. The clinical outcomes were the knee range of motion (ROM) and 2011 Knee Society Score (KSS) evaluated at 1 year postoperation. The groups were compared in terms of the TCA, PSA, number of outliers, ROM, and 2011 KSS (p < 0.05). No significant difference was observed between the groups in terms of the mean TCA, PSA, number of outliers, ROM, and categories of the 2011 KSS (objective knee indicators, symptoms, satisfaction, expectations, and functional activities). Although tibial bone cuts were performed with 3 degree varus and 7 degree posterior slope, no significant difference was observed between the OrthoPilot and iASSIST groups in terms of the accuracy of cuts or postoperative clinical result. The iASSIST was found to be a simple and useful navigation system for KA-TKA.


Author(s):  
Huitong Liu ◽  
Bingqiang Xu ◽  
Eryou Feng ◽  
Shizhang Liu ◽  
Wei Zhang ◽  
...  

Background: Imaging measurement of distal femur and proximal tibia has been the hot point in the research of total knee arthroplasty and prosthesis development, which is an important treatment for patients with advanced knee joint disease. This study retrospectively investigated the digital imaging measurement of normal knee parameters in southeast China and evaluated their clinical value. Methods: From February 2010 to May 2014, and in accordance with the inclusion criteria, a total of 677 knees (334 female knees and 343 male knees) were categorized into 3 age groups. Clinical and digital imaging data, including the distal femoral condyle diameter (FCD), tibial plateau diameter (TPD), the distance between the medial tibial plateau and fibular head (DPF), tibiofemoral valgus angle, distal femoral valgus angle, proximal tibia (PT) varus angle and the angle from femoral condyle to tibial perpendicular (FT), were measured by using AutoCAD 10.0 software. All measured variables were statistically analyzed by SPSS statistical software (version 18.0). Results: Data are presented as the mean ± standard deviation. The normal female and male femoral condyle diameter was (7.69 ± 0.46) cm and (8.68 ± 0.55) cm, while the normal female and male tibial plateau diameter was (7.66 ± 0.46) cm and (8.60 ± 0.55) cm, respectively. The normal female and male DPF was (0.76 ± 0.36) cm and (0.79 ± 0.36) cm. For females and males, the tibiofemoral valgus angle and distal femoral valgus angle were (3.89 ± 2.20) ° and (3.29 ± 2.12) °, (9.03 ± 2.18) ° and (8.25 ± 2.20) °. As the two methods to measure tibial plateau varus angle, PT angle of normal female and male was (4.29 ± 1.86) ° and (4.84 ± 2.23) °, while the normal female and male FT angle was (5.34 ± 1.95) ° and (5.52 ± 2.07) °. Based on the data obtained, we found significant differences between the two genders in terms of the femoral condyle diameter and tibial plateau diameter in all age groups (P < 0.01). The DPF parameter showed an obvious difference between the young group and the middle-aged group (P < 0.05), and no significant difference was observed between the sides and genders (P > 0.05). The distal femoral valgus angle showed statistical differences between genders in the left side of the young group and middle-aged group (P < 0.05), while angle PT and FT showed no significant difference (P > 0.05). Conclusion: A large number of knee measurements was obtained, and a local knee database was developed in this study. Imaging measurement prior to total knee arthroplasty is clinically important for increasing the accuracy and long-term efficacy of total knee arthroplasty. These data can also provide useful information for knee surgery and sports medicine as well as prosthesis development.


Sign in / Sign up

Export Citation Format

Share Document