Whole blood anticoagulant effects of Sulodexide as measured by activated clotting time and their neutralization by Protamine sulfate

2021 ◽  
Author(s):  
B Dharavath ◽  
O Iqbal ◽  
D Hoppensteadt ◽  
E Bontekoe ◽  
J Fareed
Blood ◽  
2006 ◽  
Vol 108 (11) ◽  
pp. 908-908 ◽  
Author(s):  
Walter P. Jeske ◽  
Jeanine M. Walenga ◽  
Paul D. Ackerman ◽  
Debra A. Hoppensteadt ◽  
Curtis Vandenberg ◽  
...  

Abstract Currently several generic versions of a branded low molecular weight heparin (LMWH; enoxaparin, Sanofi-Aventis, Paris, France) have become available for clinical use in several countries. Such products include Cutenox (Gland Pharma, Hyderabad, India), Dripanina (Ariston, São Paulo, Brazil) and Clenox (Pharmayect, Barranquilla, Columbia). Although these products are not currently approved for use in the U.S., several other manufacturers have sought FDA approval for their products. Due to a lack of specifications and guidelines, this approval is still pending. In order to compare the relative potency of different anti-factor Xa U/ml adjusted generic preparations, studies were designed to compare each of the individual generic LMWHs with the branded product. Additionally, multiple batches of some of the generic products were also profiled. All of the agents were tested in human whole blood and citrated plasma over a concentration range of 0.15 to 10 U/ml. Whole blood activated clotting time (ACT) and thrombelastography (TEG) measurements along with fibrinopeptide A (FPA) generation were compared. The plasmatic tests included anti-Xa and anti-IIa activity by amidolytic assay and aPTT, Heptest and PiCT clotting time assays. In addition, protamine sulfate neutralization profiles for these agents were investigated at fixed protamine concentrations of 12.5 and 25 μg/ml. In the whole blood assays, at concentrations < 2.5 U/ml, no significant differences were observed between the branded and potency adjusted generic LMWHs. However, in the plasma-based systems, assay-dependent variations were observed which were more obvious at concentrations > 1.25 U/ml (aPTT, anti-IIa, anti-Xa; p<0.05). Similarly, product and assay based variations were also observed in the protamine neutralization profile of these LMWHs. Moreover, marked differences in some assays were observed when different batches of the generic copies of LMWHs were tested. Additional studies carried out to profile the oligosaccharide composition also showed product and batch-dependent variations. The relative amounts of antithrombin affinity components among the different generic products and within product batches also exhibited some variations. These studies clearly demonstrate that some of the generic copies of enoxaparin may not produce comparable anticoagulant and thrombin generation inhibitory effects at anti-Xa potency adjusted doses. Such differences may not be clinically relevant in the prophylactic indications (dosages ≤ 40 mg O.D). However, in therapeutic or interventional indications (IV or SC dosage > 100 mg), these products may exhibit differential safety/efficacy profiles. These observations underscore the importance of clear guidelines on the chemical and biologic specifications for the acceptance of generic versions of LMWHs. Such measures are crucial to avoid any potential safety/inefficacy issues particulatly in indications where these drugs are used at higher dosages.


1977 ◽  
Author(s):  
R.D. Hamstra ◽  
G.E. Ens ◽  
S. Simons

A new coagulation instrument (Sonoclot) has been evaluated in the laboratory, at the bedside, and in surgery. It was compared to the prothrombin time, activated partial thromboplastin time, activated clotting time, Lee-White clotting time, fibrinogen and thrombelastograph. Most coagulation tests are reported as time to a clot end point while the Sonoclot records a continuous thrombokinetic pattern by measuring the energy required to maintain axial vibration of a hollow plastic probe in 0.4 ml of whole blood while it clots. Disposable plastic probes and non-siliconized glass cuvettes are rapidly changed after testing. Results are a line pattern which has been analysed for Clot Onset (C0) and Clot Formation Rate (CFR). Native whole blood from normal adults (54 studied) has a C0 of 2-4.5 minutes and CFR of 4-8 chart units/minute. The only similar clotting instrument is the thrombelastograph (TEG). Sonoclot and TEG patterns correlate, the Sonoclot sensing change before the TEG. Whole blood clotting measured with the Sonoclot is a new method which distinguishes hypercoagulation, various levels of heparin, and severe bleeding problems from normal. The device is durable, stable, easy to operate, and portable, providing a permanent record in a few minutes.


2013 ◽  
Vol 179 (2) ◽  
pp. 199
Author(s):  
M.P. Chapman ◽  
E.E. Moore ◽  
T.L. Chin ◽  
A. Ghasabyan ◽  
C.R. Ramos ◽  
...  

1998 ◽  
Vol 12 (3) ◽  
Author(s):  
Masakazu Mori ◽  
Shigenori Yoshitake ◽  
Takaaki Kitano ◽  
Shunsuke Oda ◽  
Takayuki Noguchi

2018 ◽  
Vol 20 (1) ◽  
pp. 79-86 ◽  
Author(s):  
Sheng Zhang ◽  
Amanda R Guido ◽  
Richard G Jones ◽  
Benjamin J Curry ◽  
Angela S Burke ◽  
...  

Purpose: The use of cyanoacrylate for intravenous catheter securement is of interest to clinicians and patients, because of the superior adhesive strength and hemostatic effect of cyanoacrylate compared to current securement devices. The purpose of this study is to use novel in vitro and in vivo testing methods to analyze the hemostatic effect of a catheter securement cyanoacrylate (cyanoacrylate). Methods: An unprecedented in vitro method was performed to determine the effects of a cyanoacrylate on a customized modified activated clotting time assay and blood flow inhibition assay by exposing blood or plasma to either one or three drops of cyanoacrylate. For the in vivo testing, full-thickness incisions were made on swine, and the bleeding was scored prior to treatment and at 3, 6, 9, and 12 min after treatment. Results: The cyanoacrylate rapidly achieved hemostasis in the presence of anticoagulated whole blood, platelet-poor plasma, and non-anticoagulated whole blood, in vitro. The cyanoacrylate achieved hemostasis 12-fold faster than thromboplastin in the modified activated clotting time assay. The cyanoacrylate does not alter normal blood clotting, as measured by prothrombin time. In vivo, the bleeding score of cyanoacrylate prior to treatment and at 3, 6, 9, and 12 min after treatment were 2.3 ± 1.0, 0.3 ± 0.5, 0.2 ± 0.5, 0.2 ± 0.4, and 0.2 ± 0.4, respectively. Conclusion: This study indicates that cyanoacrylate demonstrates a potent mechanical hemostatic effect and cyanoacrylate in the presence of anticoagulated whole blood has an activated clotting time that is 12 times quicker than thromboplastin. The cyanoacrylate was found to be significantly equivalent to two known hemostatic agents, in vivo.


1995 ◽  
Vol 59 (1) ◽  
pp. 106-111 ◽  
Author(s):  
George J. Despotis ◽  
J. Heinrich Joist ◽  
Diane Joiner-Maier ◽  
Alexander L. Alsoufiev ◽  
Anastasios N. Triantafillou ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document