Monitoring of ePTFE coated transjugular intrahepatic portosystemic shunt patency by contrast-enhanced ultrasound

Author(s):  
D von Renteln ◽  
B Riecken ◽  
H Weiler ◽  
A Schmidt ◽  
K Caca
2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Johannes Chang ◽  
Alexia Dumitrache ◽  
Nina Böhling ◽  
Jasmin Abu-Omar ◽  
Carsten Meyer ◽  
...  

AbstractTransjugular intrahepatic portosystemic shunt (TIPS) can treat portal hypertensive complications and modifies hepatic hemodynamics. Modification of liver perfusion can alter contrast enhancement dynamics of liver nodules. This study investigated the diagnostic performance of contrast-enhanced ultrasound (CEUS) to diagnose hepatocellular carcinoma (HCC) in cirrhosis with TIPS. In this prospective monocentric observational study, CEUS was used to characterize focal liver lesions in patients at risk for HCC with and without TIPS. Times of arterial phase hyperenhancement (APHE) und washout were quantified. Perfusion-index (PI) and resistance-index (RI) of hepatic artery and portal venous flow parameters were measured via doppler ultrasonography. Diagnostic gold standard was MRI/CT or histology. This study included 49 liver lesions [23 TIPS (11 HCC), 26 no TIPS (15 HCC)]. 26 were diagnosed as HCC by gold standard. Sensitivity and specificity of CEUS to diagnose HCC with and without TIPS were 93.3% and 100% vs. 90.9% and 93.3%, respectively. APHE appeared significantly earlier in patients with TIPS compared to patients without TIPS. TIPS significantly accentuates APHE of HCC in CEUS. CEUS has good diagnostic performance for diagnosis of HCC in patients with TIPS.


Diagnostics ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 1593
Author(s):  
Constantin A. Marschner ◽  
Thomas Geyer ◽  
Matthias F. Froelich ◽  
Johannes Rübenthaler ◽  
Vincent Schwarze ◽  
...  

Background: In patients with liver cirrhosis, transjugular intrahepatic portosystemic shunt (TIPS) displays an effective method for treating portal hypertension. Main indications include refractory ascites and secondary prevention of esophageal bleeding. Color Doppler ultrasound (CDUS) plays a leading role in the follow-up management, whereas contrast-enhanced ultrasound (CEUS) is not routinely considered. We compared the efficacy of CEUS to CDUS and highlighted differences compared to findings of corresponding computed tomography (CT) and magnetic resonance imaging (MRI). (2) Methods: On a retrospective basis, 106 patients with CEUS examination after TIPS were included. The enrollment period was 12 years (between 2008 and 2020) and the age group ranged from 23.3 to 82.1 years. In addition, 92 CDUS, 43 CT and 58 MRI scans were evaluated for intermodal comparison. (3) Results: Intermodal analysis and comparison revealed a high level of concordance between CDUS, CT and MRI in the vast majority of cases. In comparison to CDUS, the correlation of the relevant findings was 92.5%, 95.3% for CT and 87.9% for MRI. In some cases, however, additional information was provided by CEUS (4) Conclusions: CEUS depicts a safe and effective imaging modality for follow-up after TIPS. In addition to CDUS, CEUS enables specific assessment of stent pathologies and stent dysfunction due to its capacity to dynamically visualize single microbubbles at high spatial and temporal resolution. Due to the low number of adverse events regarding the application of contrast agents, CEUS can be administered to a very broad patient population, thus avoiding additional radiation exposure compared to CT angiography in cases with divergent findings during follow-up.


2020 ◽  
Vol 45 (11) ◽  
pp. 3934-3943
Author(s):  
Timo C. Meine ◽  
Cornelia L. A. Dewald ◽  
L. S. Becker ◽  
Aline Mähringer-Kunz ◽  
Benjamin Massoumy ◽  
...  

Abstract Background To assess the technical feasibility, success rate, puncture complications and procedural characteristics of transjugular intrahepatic portosystemic shunt (TIPS) placement using a three-dimensional vascular map (3D-VM) overlay based on image registration of pre-procedural contrast-enhanced (CE) multi-detector computed tomography (MDCT) for portal vein puncture guidance. Materials and methods Overall, 27 consecutive patients (59 ± 9 years, 18male) with portal hypertension undergoing elective TIPS procedure were included. TIPS was guided by CE-MDCT overlay after image registration based on fluoroscopic images. A 3D-VM of the hepatic veins and the portal vein was created based on the pre-procedural CE-MDCT and superimposed on fluoroscopy in real-time. Procedural characteristics as well as hepatic vein catheterization time (HVCT), puncture time (PT), overall procedural time (OPT), fluoroscopy time (FT) and the dose area product (DAP) were evaluated. Thereafter, HVCT, PT, OPT and FT using 3D-VM (61 ± 9 years, 14male) were compared to a previous using classical fluoroscopic guidance (53 ± 9 years, 21male) for two interventional radiologist with less than 3 years of experience in TIPS placement. Results All TIPS procedure using of 3D/2D image registered 3D-VM were successful with a significant reduction of the PSG (p < 0.0001). No clinical significant complication occurred. HVCT was 14 ± 11 min, PT was 14 ± 6 min, OPT was 64 ± 29 min, FT was 21 ± 12 min and DAP was 107.48 ± 93.84 Gy cm2. HVCT, OPT and FT of the interventionalist with less TIPS experience using 3D/2D image registered 3D-VM were statistically different to an interventionalist with similar experience using fluoroscopic guidance (pHVCT = 0.0022; pOPT = 0.0097; pFT = 0.0009). PT between these interventionalists was not significantly different (pPT = 0.2905). Conclusion TIPS placement applying registration-based CE-MDCT vessel information for puncture guidance is feasible and safe. It has the potential to improve hepatic vein catherization, portal vein puncture and radiation exposure.


Sign in / Sign up

Export Citation Format

Share Document