Contrast-enhanced ultrasound at high mechanical index: a new method for transjugular intrahepatic portosystemic shunt follow-up

2020 ◽  
Vol 75 (4) ◽  
pp. 302-307 ◽  
Author(s):  
X. Gao ◽  
H.H. Wang ◽  
Y.Z. Zhang ◽  
X.B. Liu ◽  
X.C. Qin
Diagnostics ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 1593
Author(s):  
Constantin A. Marschner ◽  
Thomas Geyer ◽  
Matthias F. Froelich ◽  
Johannes Rübenthaler ◽  
Vincent Schwarze ◽  
...  

Background: In patients with liver cirrhosis, transjugular intrahepatic portosystemic shunt (TIPS) displays an effective method for treating portal hypertension. Main indications include refractory ascites and secondary prevention of esophageal bleeding. Color Doppler ultrasound (CDUS) plays a leading role in the follow-up management, whereas contrast-enhanced ultrasound (CEUS) is not routinely considered. We compared the efficacy of CEUS to CDUS and highlighted differences compared to findings of corresponding computed tomography (CT) and magnetic resonance imaging (MRI). (2) Methods: On a retrospective basis, 106 patients with CEUS examination after TIPS were included. The enrollment period was 12 years (between 2008 and 2020) and the age group ranged from 23.3 to 82.1 years. In addition, 92 CDUS, 43 CT and 58 MRI scans were evaluated for intermodal comparison. (3) Results: Intermodal analysis and comparison revealed a high level of concordance between CDUS, CT and MRI in the vast majority of cases. In comparison to CDUS, the correlation of the relevant findings was 92.5%, 95.3% for CT and 87.9% for MRI. In some cases, however, additional information was provided by CEUS (4) Conclusions: CEUS depicts a safe and effective imaging modality for follow-up after TIPS. In addition to CDUS, CEUS enables specific assessment of stent pathologies and stent dysfunction due to its capacity to dynamically visualize single microbubbles at high spatial and temporal resolution. Due to the low number of adverse events regarding the application of contrast agents, CEUS can be administered to a very broad patient population, thus avoiding additional radiation exposure compared to CT angiography in cases with divergent findings during follow-up.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Johannes Chang ◽  
Alexia Dumitrache ◽  
Nina Böhling ◽  
Jasmin Abu-Omar ◽  
Carsten Meyer ◽  
...  

AbstractTransjugular intrahepatic portosystemic shunt (TIPS) can treat portal hypertensive complications and modifies hepatic hemodynamics. Modification of liver perfusion can alter contrast enhancement dynamics of liver nodules. This study investigated the diagnostic performance of contrast-enhanced ultrasound (CEUS) to diagnose hepatocellular carcinoma (HCC) in cirrhosis with TIPS. In this prospective monocentric observational study, CEUS was used to characterize focal liver lesions in patients at risk for HCC with and without TIPS. Times of arterial phase hyperenhancement (APHE) und washout were quantified. Perfusion-index (PI) and resistance-index (RI) of hepatic artery and portal venous flow parameters were measured via doppler ultrasonography. Diagnostic gold standard was MRI/CT or histology. This study included 49 liver lesions [23 TIPS (11 HCC), 26 no TIPS (15 HCC)]. 26 were diagnosed as HCC by gold standard. Sensitivity and specificity of CEUS to diagnose HCC with and without TIPS were 93.3% and 100% vs. 90.9% and 93.3%, respectively. APHE appeared significantly earlier in patients with TIPS compared to patients without TIPS. TIPS significantly accentuates APHE of HCC in CEUS. CEUS has good diagnostic performance for diagnosis of HCC in patients with TIPS.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ulf K. Radunski ◽  
Johannes Kluwe ◽  
Malte Klein ◽  
Antonio Galante ◽  
Gunnar K. Lund ◽  
...  

AbstractTransjugular intrahepatic portosystemic shunt (TIPS) reduces portal hypertension in patients with liver cirrhosis. The exact cardiac consequences of subsequent increase of central blood volume are unknown. Cardiovascular magnetic resonance (CMR) imaging is the method of choice for quantifying cardiac volumes and ventricular function. The aim of this study was to investigate effects of TIPS on the heart using CMR, laboratory, and imaging cardiac biomarkers. 34 consecutive patients with liver cirrhosis were evaluated for TIPS. Comprehensive CMR with native T1 mapping, transthoracic echocardiography, and laboratory biomarkers were assessed before and after TIPS insertion. Follow-up (FU) CMR was obtained in 16 patients (47%) 207 (170–245) days after TIPS. From baseline (BL) to FU, a significant increase of all indexed cardiac chamber volumes was observed (all P < 0.05). Left ventricular (LV) end-diastolic mass index increased significantly from 45 (38–51) to 65 (51–73) g/m2 (P =  < 0.01). Biventricular systolic function, NT-proBNP, high-sensitive troponin T, and native T1 time did not differ significantly from BL to FU. No patient experienced cardiac decompensation following TIPS. In conclusion, in patients without clinically significant prior heart disease, increased cardiac preload after TIPS resulted in increased volumes of all cardiac chambers and eccentric LV hypertrophy, without leading to cardiac impairment during follow-up in this selected patient population.


Sign in / Sign up

Export Citation Format

Share Document